RCI1MAG-87K
MILLIPLEX® Rat Cardiac Injury Panel 1 - Cardiotoxicity Multiplex Assay
About This Item
Empfohlene Produkte
Speziesreaktivität
rat
Qualitätsniveau
Hersteller/Markenname
Milliplex®
assay range
recovery range: 80-100%
(2 Hour Protocol)
recovery range: 86-103%
(Overnight Protocol)
sensitivity: 7-155 pg/mL
(Overnight Protocol; MinDC+2SD)
sensitivity: 9-86 pg/mL
(2 Hour Protocol; MinDC+2SD)
standard curve range: 123-90,000 pg/mL
(cTnI)
standard curve range: 21-15,000 pg/mL
(CKM)
standard curve range: 4-3,000 pg/mL
(MYL3)
standard curve range: 41-30,000 pg/mL
(FABP3)
standard curve range: 41-30,000 pg/mL
(TIMP-1)
standard curve range: 82-60,000 pg/mL
(FSTL1)
standard curve range: 82-60,000 pg/mL
(cTnT)
Methode(n)
multiplexing: suitable
Nachweisverfahren
fluorometric (Luminex xMAP)
Versandbedingung
wet ice
Allgemeine Beschreibung
In order to meet the increasing need to provide screening assays for experimental biomarkers of drug-induced cardiac injury in pre-clinical and translational research models, we have developed the MILLIPLEX® Rat Cardiac Injury Bead Panel 1. This configurable 7-plex panel is the most versatile system available for cardiac injury screening in pre-clinical and translational research models.
The MILLIPLEX® Rat Cardiac Injury Bead Panel 1 (RCI1MAG-87K) contains all the components necessary to simultaneous quantify any or all of the following 7 analytes in serum and plasma samples: Cardiac Troponin I (cTnI), Cardiac Troponin T (cTnT), Creatine Kinase, Muscle (CKM), Fatty Acid Binding Protein 3 (FABP3), Follistatin-like Protein 1 (FSTL1), Myosin Light Chain 3 (MYL3), Tissue Inhibitor of Metalloproteinase-1 (TIMP-1).
This kit uses a 96-well format, contains lyophilized standard cocktail and two quality controls, and can measure up to 38 serum or plasma samples in duplicate.
Panel Type: Toxicity
Spezifität
There was no or negligible cross-reactivity between the antibodies for an analyte and any of the other analytes within a panel.
Anwendung
- Analytes: Cardiac Troponin I (cTnI), Cardiac Troponin T (cTnT), Creatine Kinase Muscle (CKM), Fatty Acid Binding Protein 3 (FABP3), Follistatin-like Protein 1 (FSTL1), Myosin Light Chain 3 (MYL3), Tissue Inhibitor of Metalloproteinase-1 (TIMP-1)
- Recommended Sample Type: Rat serum or plasma
- Recommended Sample dilution: 25 μL per well of 1:5 diluted serum or plasma
- Assay Run Time: Overnight (16-18 hours) at 2-8°C or 2 hours at room temperature (20-25°C).
- Research Category: Toxicity
- Research Subcategory: Cardiovascular
Leistungsmerkmale und Vorteile
Verpackung
Komponenten
Rat Cardiac Injury Quality Control 1, 1 vial, lyophilized
Rat Cardiac Injury Quality Control 2, 1 vial, lyophilized
Serum Matrix (0.08% Sodium Azide), 1 vial, lyophylized
Assay Buffer, 1 bottle, 30 mL
Wash Buffer, 10X (0.05% Proclin), 2 bottles, 30 mL ea
Rat Cardiac Injury Panel 1 Detection Antibodies, 1 bottle, 3.2 mL
Rat Cardiac Injury Panel 1 Antibody-Immobilized Beads (20X), 200 µL ea
Streptavidin-Phycoerythrin, 1 bottle, 3.2 mL
Mixing Bottle, 1 bottle
Sample Plate, 96 well format, 1 plate
2 Foil Plate Sealers
Lagerung und Haltbarkeit
Sonstige Hinweise
Rechtliche Hinweise
Haftungsausschluss
Signalwort
Danger
Gefahreneinstufungen
Acute Tox. 3 Dermal - Acute Tox. 4 Inhalation - Acute Tox. 4 Oral - Aquatic Chronic 2 - Eye Dam. 1 - Skin Sens. 1 - STOT RE 2
Zielorgane
Respiratory Tract
Lagerklassenschlüssel
6.1C - Combustible acute toxic Cat.3 / toxic compounds or compounds which causing chronic effects
Analysenzertifikate (COA)
Suchen Sie nach Analysenzertifikate (COA), indem Sie die Lot-/Chargennummer des Produkts eingeben. Lot- und Chargennummern sind auf dem Produktetikett hinter den Wörtern ‘Lot’ oder ‘Batch’ (Lot oder Charge) zu finden.
Besitzen Sie dieses Produkt bereits?
In der Dokumentenbibliothek finden Sie die Dokumentation zu den Produkten, die Sie kürzlich erworben haben.
Verwandter Inhalt
UnEnhance research with MILLIPLEX® multiplexing tips, industry guidance, and one-day assays for limited lab time.
Discover the benefits of MILLIPLEX® multiplex assays, based on Luminex® xMAP® multiplex assay technology, that provide consistent, high-quality results and see how these multiplex biomarker Luminex® assays are being used to advance research.
Unser Team von Wissenschaftlern verfügt über Erfahrung in allen Forschungsbereichen einschließlich Life Science, Materialwissenschaften, chemischer Synthese, Chromatographie, Analytik und vielen mehr..
Setzen Sie sich mit dem technischen Dienst in Verbindung.