Direkt zum Inhalt
Merck

MRCF0R100

Millipore

Microcon® DNA Fast Flow Zentrifugenfilter

sample volume 0.5 mL, Ultracel® regenerated cellulose membrane (low binding)

Synonym(e):

Centrifuge concentrator

Anmeldenzur Ansicht organisationsspezifischer und vertraglich vereinbarter Preise

Größe auswählen

100 EA
€ 563,00

€ 563,00


Voraussichtliches Versanddatum30. Mai 2025


Bulk-Bestellung anfordern

Größe auswählen

Ansicht ändern
100 EA
€ 563,00

About This Item

UNSPSC-Code:
41104916
eCl@ss:
36100101
NACRES:
NB.24

€ 563,00


Voraussichtliches Versanddatum30. Mai 2025


Bulk-Bestellung anfordern

Materialien

Ultracel® regenerated cellulose membrane (low binding)
polyacetal base (membrane support)
polycarbonate device top
polypropylene tube (for filtrate/concentrate)
silicone O-ring (medical-grade)

Qualitätsniveau

Sterilität

non-sterile

Leistungsmerkmale

holdup volume> 10 μL

Verpackung

pkg of 100 ea

Hersteller/Markenname

Microcon®

Parameter

0.5 mL sample volume

Methode(n)

DNA purification: suitable
RNA purification: suitable

Länge

4.50 cm (1.8 in.)

Durchmesser

12.3 mm

Filtrationsfläche

0.32 cm2

Arbeitsvolumen

0.5 mL

Versandbedingung

ambient

Verwandte Kategorien

Allgemeine Beschreibung

Microcon® Zentrifugenfilter bieten eine effiziente Konzentrierung, Entsalzung oder einen Pufferaustausch von wässrigen biologischen Proben mit einem Volumen im Bereich von 10–500 μl. Der Microcon® DNA Fast Flow Filter ist für die Konzentrierung und Rückgewinnung von genomischer DNA mit SDS-Puffer optimiert.

Anwendung

Microcon DNA Fast Flow Zentrifugenfiltereinheit mit Ultracel-Membran wird zum Extrahieren von normaler organischer DNA eingesetzt, um DNA-Ausbeuten von alternativen Extraktionsverfahren zu vergleichen.[1] Sie wird auch zum Filtrieren der aufgeschlossenen DNA für die Elektronenmikroskopanalyse von genomischer DNA eingesetzt.[2]

Leistungsmerkmale und Vorteile

Microcon® Zentrifugenfilter haben mehrere Vorteile:
  • hohe Rückgewinnung für kleine Volumen mit Umkehr-Spin
  • Ultracel® Membran mit geringer Bindung
  • schnelle Verarbeitung
  • ergeben Konzentrationsfaktoren von <20 X für eine konsistente Reproduzierbarkeit

Verlinkung

Ersetzt: 42413

Rechtliche Hinweise

MICROCON is a registered trademark of Merck KGaA, Darmstadt, Germany
ULTRACEL is a registered trademark of Merck KGaA, Darmstadt, Germany

Analysenzertifikate (COA)

Suchen Sie nach Analysenzertifikate (COA), indem Sie die Lot-/Chargennummer des Produkts eingeben. Lot- und Chargennummern sind auf dem Produktetikett hinter den Wörtern ‘Lot’ oder ‘Batch’ (Lot oder Charge) zu finden.

Besitzen Sie dieses Produkt bereits?

In der Dokumentenbibliothek finden Sie die Dokumentation zu den Produkten, die Sie kürzlich erworben haben.

Die Dokumentenbibliothek aufrufen

Bacillus spp. Bacteriophage and the Dairy Environment
Adamso KL and McKillip JL
Liaoning Chemical Industry, 23(2), 4-4 (2019)
Matteo Berti et al.
Nature communications, 11(1), 3531-3531 (2020-07-17)
Homologous recombination (HR) factors were recently implicated in DNA replication fork remodeling and protection. While maintaining genome stability, HR-mediated fork remodeling promotes cancer chemoresistance, by as-yet elusive mechanisms. Five HR cofactors - the RAD51 paralogs RAD51B, RAD51C, RAD51D, XRCC2 and

Verwandter Inhalt

Microcon® Centrifugal Filters simply and efficiently concentrate and desalt solutions of DNA, RNA, protein or other macromolecules, using any centrifuge that can accept 1.5 mL tubes.

Questions

1–3 of 3 Questions  
  1. Can I use a Microcon DNA fast flow device to isolate DNA from a crude cell lysis preparation such a freeze thaw in TE buffer or a chelex 100 extraction?

    1 answer
    1. Yes, a Microcon DNA fast flow device can be used to isolate DNA from a crude cell lysis preparation. However, lysates typically contain heavy particulate contamination, so clarification spins may be necessary to remove particulates before attempting ultrafiltration.

      Helpful?

  2. The user guide indicates you can't autoclave these microcon, but can you sterilize them in a UV Crosslinker?

    1 answer
    1. The Microcon devices are non-sterile. These devices cannot be sterilized by UV or autoclaving. However, it is possible to sanitize the devices with 70% ethanol. Please see the protocol for sanitization below:

      1. Reagent Preparation: 70% Ethanol solution (v/v) is prepared by dilution in distilled water. Both the ethanol solution and distilled water used for rinsing should be filter-sterilized using sterile, 0.22 µm sterilizing grade filter device.

      2.Sanitization Protocol:

      A. Fill the Microcon device to its published capacity with filter-sterilized 70% ethanol, and cap the unit (note that the collection tubes can be sanitized in the same manner).

      B. Invert device by hand or in an end-over-end mixer to continuously wet all internal surfaces of the device.

      C. Incubate for a minimum of 5 minutes (note that the device can be capped and left for up to 24 hours if it is not going to be used immediately).

      D. Spin at recommended G-force using appropriate centrifuge until at least 50% of the volume has passed through the device.

      E. Aseptically discard any remaining ethanol from the filter device and filter collection tube.

      F. Immediately rinse away residual ethanol by adding the filter-sterilized water to the device's published capacity, mix gently to wet all areas, and centrifuge until at least 50% of the volume has passed through the device.

      G. Discard any remaining liquid from both the concentrator device and filter collection tube before use.

      DO NOT let the filter membrane dry out in concentrator unit. If the devices are not to be used immediately, fill the devices with filter-sterilized distilled water, cover, and store refrigerated. Remove liquid from device as previously described prior to use.

      Helpful?

  3. Has the color of the Microcon DNA Fast Flow become brighter blue?

    1 answer
    1. Yes, the color of the device has changed. A new blue colorant and clear resin have replaced the original blue reservoir resin, which has been discontinued. Both old and new resin are HP2 Polycarbonate. The functionality of the product has not changed.

      Helpful?

Reviews

No rating value

Active Filters

Unser Team von Wissenschaftlern verfügt über Erfahrung in allen Forschungsbereichen einschließlich Life Science, Materialwissenschaften, chemischer Synthese, Chromatographie, Analytik und vielen mehr..

Setzen Sie sich mit dem technischen Dienst in Verbindung.