Our R&D team conducted spike recovery and dilution linearity tests in rat serum samples. The sequence for both rat and mouse is identical. Although we attempted to develop this kit for both rat and mouse, the recovery in rats was considerably lower compared to mice. As a result, we do not recommend this kit for use with rats. Verification tests were not carried out in cerebrospinal fluid (CSF) or rat brain samples to assess potential improvement in recovery for other sample types.
HNDG4MAG-36K
MILLIPLEX® Human Neurodegenerative Disease Magnetic Bead Panel 4 - Neuroscience Multiplex Assay
The analytes available for this multiplex kit are: Amyloid β40, Amyloid β42, GDNF, sRAGE, S100B.
About This Item
Empfohlene Produkte
Qualitätsniveau
Speziesreaktivität
human
Hersteller/Markenname
Milliplex®
assay range
accuracy: 84-108%
standard curve range: 14-10,000 pg/mL
(S100B)
standard curve range: 21-15,000 pg/mL
(sRAGE)
standard curve range: 27-20,000 pg/mL
(Amyloid β42)
standard curve range: 3-2,500 pg/mL
(Amyloid β40)
standard curve range: 7-5,000 pg/mL
(GDNF)
Methode(n)
multiplexing: suitable
Nachweisverfahren
fluorometric (Luminex xMAP)
Versandbedingung
wet ice
Allgemeine Beschreibung
Panel Type: Neuroscience
Spezifität
Cross-reactivity between the antibodies and any of the other analytes in this panel is non-detectable or negligible.
Anwendung
- Analytes: Amyloid β40, Amyloid β42, GDNF, sRAGE, S100B
- Recommended Sample type: CSF
- Recommended Sample dilution: 1:3
- Assay Run Time: Overnight
- Research Category: Neuroscience
Leistungsmerkmale und Vorteile
Verpackung
Lagerung und Haltbarkeit
Sonstige Hinweise
Rechtliche Hinweise
Haftungsausschluss
Signalwort
Danger
H-Sätze
Gefahreneinstufungen
Acute Tox. 3 Dermal - Acute Tox. 4 Inhalation - Acute Tox. 4 Oral - Aquatic Chronic 2 - Skin Sens. 1
Lagerklassenschlüssel
6.1C - Combustible acute toxic Cat.3 / toxic compounds or compounds which causing chronic effects
Analysenzertifikate (COA)
Suchen Sie nach Analysenzertifikate (COA), indem Sie die Lot-/Chargennummer des Produkts eingeben. Lot- und Chargennummern sind auf dem Produktetikett hinter den Wörtern ‘Lot’ oder ‘Batch’ (Lot oder Charge) zu finden.
Besitzen Sie dieses Produkt bereits?
In der Dokumentenbibliothek finden Sie die Dokumentation zu den Produkten, die Sie kürzlich erworben haben.
Verwandter Inhalt
Learn how multiplex detection of Alzheimer’s disease biomarkers, using the MILLIPLEX® Human Amyloid Beta and Tau Magnetic Bead Panel, allows for a different perspective on neurodegenerative disease research.
Neuroscience multiplex assays, such as MILLIPLEX® multiplex assays, enable simultaneous measurement of neuroscience-related biomarkers to gain a better picture of neurodegenerative diseases, neurological disorders, and neuropeptide/neurohormone signaling.
-
Is the Milliplex Mouse Amyloid Beta Panel (MABMAG-83K) suitable for testing rat samples?
1 answer-
Helpful?
-
-
What is the reason that GLP-1 total and active cannot be run together in HMHEMAG-34K?
1 answer-
The same capture is used for both total and active GLP-1; however, the detection is specific to either total or active GLP-1.
Helpful?
-