跳轉至內容
Merck
  • Molecularly imprinted polymer dedicated to the extraction of glyphosate in natural waters.

Molecularly imprinted polymer dedicated to the extraction of glyphosate in natural waters.

Journal of chromatography. A (2014-08-26)
K Puzio, B Claude, L Amalric, C Berho, E Grellet, S Bayoudh, R Nehmé, Ph Morin
摘要

Three molecularly imprinted polymers (MIPs) have been synthesized in order to bind efficiently glyphosate (GLY) in natural waters (mineral and underground). Since the target analyte is polar and hydrophilic, electrostatic interactions and hydrogen bonds have been favored with two templates (phenylphosphonic acid and diethyl(α-aminobenzyl)-phosphonic acid) and two functional monomers (1-allyl-2-thiourea and methacrylic acid). MIPs have been assessed by comparison of the recoveries obtained with MIP and NIP (non imprinted polymer) by solid-phase extraction (SPE). The selectivity of MIP versus NIP was satisfactory for the three imprinted polymers with a very straightforward protocol: conditioning of 250 mg of MIP or NIP packed in 3-mL polypropylene cartridges with 3 mL Milli-Q water, loading of Milli-Q water (15 mL) spiked with 5 mg L(-1) of GLY and its metabolite, aminomethylphosphonic acid (AMPA) and elution by 3 mL NH4OH (10mM) or 3 mL HCl (100mM). SPE fractions were directly analyzed by capillary electrophoresis (CE). Thus, the recoveries of both analytes were greater than 80% for all MIPs and less than 25% for most NIPs. Moreover, the MIP prepared with 1-allyl-2-thiourea as functional monomer and phenylphosphonic acid as template displayed a capacity of 0.033 μmol/mg for GLY. However, the substitution of Milli-Q water by mineral water caused the decrease of MIP recoveries, for that, a pretreatment of the sample by ionic exchange resins was set up and succeeded in improving recoveries (about 50% for GLY and 25% for AMPA). Then, groundwaters were spiked with low concentrations of GLY and AMPA (0.5 μgL(-1)) and directly percolated through MIP cartridges. The extractions were carried out by triplicate and the elution fractions were analyzed by UPLC-MS/MS. The results showed no retention of AMPA but a total retention of GLY by MIP.

材料
產品編號
品牌
產品描述

Sigma-Aldrich
乙酸铵, ACS reagent, ≥97%
Sigma-Aldrich
溴化十六烷基三甲铵, ≥98%
Sigma-Aldrich
乙酸铵, ≥99.99% trace metals basis
Sigma-Aldrich
MES, low moisture content, ≥99% (titration)
Sigma-Aldrich
溴化十六烷基三甲铵, for molecular biology, ≥99%
Sigma-Aldrich
2,2′-偶氮(2-甲基丙腈), 98%
Sigma-Aldrich
L-组氨酸, suitable for cell culture, meets EP, USP testing specifications, from non-animal source
Sigma-Aldrich
甲基丙烯酸, contains 250 ppm MEHQ as inhibitor, 99%
Sigma-Aldrich
乙二醇二甲基丙烯酸酯, 98%, contains 90-110 ppm monomethyl ether hydroquinone as inhibitor
Sigma-Aldrich
乙酸铵, for molecular biology, ≥98%
Sigma-Aldrich
氯甲酸-9-芴基甲酯, 97%
Sigma-Aldrich
溴化十六烷基三甲铵, BioXtra, ≥99%
Sigma-Aldrich
乙酸铵 溶液, for molecular biology, 7.5 M
SAFC
L-组氨酸
Sigma-Aldrich
L-组氨酸, BioUltra, ≥99.5% (NT)
Supelco
乙酸铵, LiChropur, eluent additive for LC-MS
Sigma-Aldrich
溴化十六烷基三甲铵, BioUltra, for molecular biology, ≥99.0% (AT)
Sigma-Aldrich
乙酸铵, 99.999% trace metals basis
Sigma-Aldrich
2,2′-偶氮(2-甲基丙腈), recrystallized from methanol, 99%
Sigma-Aldrich
L-组氨酸, ReagentPlus®, ≥99% (TLC)
Sigma-Aldrich
氨甲基膦酸, 99%
Sigma-Aldrich
苯膦酸, 98%
Supelco
草甘膦, PESTANAL®, analytical standard
Sigma-Aldrich
乙酸铵, reagent grade, ≥98%
Sigma-Aldrich
N-(磷酰基甲基)甘氨酸, 96%
Sigma-Aldrich
MES 溶液, BioUltra, for molecular biology, 0.5 M in H2O
Sigma-Aldrich
邻苯二甲酸, ACS reagent, ≥99.5%
Sigma-Aldrich
N-(磷酰基甲基)甘氨酸, BioReagent, suitable for plant cell culture
Supelco
氯甲酸-9-芴基甲酯, for HPLC derivatization, LiChropur, ≥99.0% (HPLC)
Sigma-Aldrich
氯甲酸-9-芴基甲酯, BioReagent, ≥99.0% (HPLC)