跳轉至內容
Merck
全部照片(1)

重要文件

CRM67622

Supelco

Tralomethrin

mixture of stereoisomers, certified reference material, TraceCERT®, Manufactured by: Sigma-Aldrich Production GmbH, Switzerland

同義詞:

(S)-α-Cyano-3-phenoxybenzyl (1R,3S)-2,2-dimethyl-3-[(RS)-1,2,2,2-tetrabromoethyl]cyclopropanecarboxylate

登入查看組織和合約定價


About This Item

經驗公式(希爾表示法):
C22H19Br4NO3
CAS號碼:
分子量::
665.01
MDL號碼:
分類程式碼代碼:
41116107
NACRES:
NA.24
暫時無法取得訂價和供貨情況

等級

certified reference material
TraceCERT®

品質等級

產品線

TraceCERT®

儲存期限

limited shelf life, expiry date on the label

製造商/商標名

Manufactured by: Sigma-Aldrich Production GmbH, Switzerland

形式

neat

儲存溫度

2-8°C

SMILES 字串

O=C(OC(C#N)C1=CC=CC(OC2=CC=CC=C2)=C1)C3C(C(Br)C(Br)(Br)Br)C3(C)C

InChI

1S/C22H19Br4NO3/c1-21(2)17(19(23)22(24,25)26)18(21)20(28)30-16(12-27)13-7-6-10-15(11-13)29-14-8-4-3-5-9-14/h3-11,16-19H,1-2H3

InChI 密鑰

YWSCPYYRJXKUDB-UHFFFAOYSA-N

尋找類似的產品? 前往 產品比較指南

一般說明

This certified reference material (CRM) is produced and certified in accordance with ISO/IEC 17025 and ISO 17034. This CRM is traceable to primary material from an NMI, e.g. NIST or NMIJ.
Certified content by quantitative NMR incl. uncertainty and expiry date are given on the certificate.
Download your certificate at: http://www.sigma-aldrich.com
Tralomethrin is a synthetic Type II pyrethroid insecticide that contains an a-cyano group and shows more neurotoxicity than Type I insecticides. It acts by modifying the kinetics of the voltage-gated sodium channels present in the axonal membranes of neurons. In addition, the voltage-gated calcium and chloride channels and GABA (gamma amino butyric acid) receptors are the secondary target sites for tralomethrin.
Tralomethrin is not approved for use in the European Union (EU) as per the Commission Regulation (EC) No 2076/2002 of 20th November 2002 as a plant protection agent under Regulation (EC) No. 1107/2009, repealing the directive 91/414/EEC. But a default maximum residue limit (MRL) of 0.01 mg/kg is applicable for its presence in products of plant origin according to Art 18(1)(b) Reg 396 / 2005.

應用

The certified reference material (CRM) is intended to be used as a calibrant for chromatography and other analytical techniques.
The tralomethrin CRM may also be used as below:

  • Develop and validate a method relying on the use of a vibrational shaker and QuEChERS-based extraction, accompanied by LC-MS/MS detection to detect 22 antiparasitic drug residues in 36 fish tissue samples
  • Analysis of fat obtained from different animals for the presence of 1 pyrethrin and 18 pyrethroid residues by UHPLC-MS/MS
  • Multi-residue analysis of 379 pesticides in human serum by liquid chromatography-tandem mass spectrometry (LC-MS/MS)
  • Quantification of 19 pyrethroid residues in 262 tea and 209 peeled orange samples by liquid chromatography-electrospray ionization-triple quadrupole mass spectrometry (LC-ESI-QqQ-MS/MS) and their detection by liquid chromatography-electrospray ionization-quadrupole-time-of-flight mass spectrometry (LC-ESI-Q-ToF/MS)
  • Simultaneous determination of 12 pyrethroid insecticide residues in water, sediment, and milk samples by gas chromatography coupled with tandem mass spectrometry (GC/MS/MS) in two different ionization modes of electron ionization (EI) and negative chemical ionization (NCI)
  • Multi-residue determination of 17 pesticide residues in brown rice, onion, and spinach samples by supercritical fluid chromatography-tandem mass spectrometry (SFC-MS/MS)

法律資訊

TraceCERT is a registered trademark of Merck KGaA, Darmstadt, Germany

象形圖

Exclamation markEnvironment

訊號詞

Warning

危險分類

Acute Tox. 4 Oral - Aquatic Acute 1 - Aquatic Chronic 1 - Eye Irrit. 2 - Skin Irrit. 2

儲存類別代碼

11 - Combustible Solids

水污染物質分類(WGK)

WGK 3

閃點(°F)

Not applicable

閃點(°C)

Not applicable


從最近期的版本中選擇一個:

分析證明 (COA)

Lot/Batch Number

It looks like we've run into a problem, but you can still download Certificates of Analysis from our 文件 section.

如果您需要協助,請聯絡 客戶支援

已經擁有該產品?

您可以在文件庫中找到最近購買的產品相關文件。

存取文件庫

Megumi Ishibashi et al.
Journal of chromatography. A, 1266, 143-148 (2012-10-30)
Combination techniques such as gas chromatography/mass spectrometry (GC/MS) and liquid chromatography/mass spectrometry (LC/MS) are commonly used for pesticide residue analysis, but there is no reported method for the simultaneous analysis of multiple pesticides in a sample using a single instrument.
Comprehensive target analysis for 19 pyrethroids in tea and orange samples based on LC-ESI-QqQ-MS/MS and LC-ESI-Q-ToF/MS
Wan J, et al.
LWT--Food Science and Technology, 151, 112072-112072 (2021)
Lenise Guimarães de Oliveira et al.
Analytical and bioanalytical chemistry, 411(26), 6913-6929 (2019-08-17)
A method was developed for the analysis of 22 antiparasitic residues belonging to the benzoylurea, organophosphate, pyrimidinamine, pyrethrin and pyrethroid classes in salmon by liquid chromatography coupled with tandem mass spectrometry. Samples were extracted with acetonitrile-water as the extraction solvent
M Moloney et al.
Journal of chromatography. B, Analytical technologies in the biomedical and life sciences, 1077-1078, 60-70 (2018-02-08)
A method was developed for the confirmatory and quantitative analysis of one pyrethrin and 18 pyrethroid residues in animal fat. Fat was extracted was collected from adipose tissue melted in an oven at 65 °C for 2 h. Fat samples (1 g) were
M L Feo et al.
Rapid communications in mass spectrometry : RCM, 25(7), 869-876 (2011-03-19)
The performance of gas chromatography coupled with tandem mass spectrometry (GC/MS/MS) was tested for the simultaneous determination of twelve pyrethroid insecticides. First, a comparison of two different ionization modes, electron ionization (EI) and negative chemical ionization (NCI), was carried out

Questions

Reviews

No rating value

Active Filters

我們的科學家團隊在所有研究領域都有豐富的經驗,包括生命科學、材料科學、化學合成、色譜、分析等.

聯絡技術服務