MAK157

Sigma-Aldrich

肾素检测试剂盒

Renin Assay Kit
1 of 1 reviewers received a sample product or took part in a promotion

sufficient for 100 fluorometric tests

同義詞:

肾素检测试剂盒

登入查看組織和合約定價


About This Item

分類程式碼代碼:
12161503
NACRES:
NA.84
暫時無法取得訂價和供貨情況

用途

sufficient for 100 fluorometric tests

檢測方法

fluorometric

相關疾病

cardiovascular diseases

儲存溫度

−20°C

基因資訊

human ... REN(5972)
rat ... REN(24715)

一般說明

肾素,也称为血管紧张素原酶,是一种天冬氨酰蛋白酶,可切割血管紧张素原,形成血管紧张素 I,这是肾素-血管紧张素系统(RAS)的初始和限速步骤。该系统在血压和体液平衡的调节中起关键作用。由于血管收缩和液体潴留增加,肾素活性增加可导致高血压。肾素抑制剂可用于高血压的治疗。[1]

應用

肾素检测试剂盒已用于测定肾素的活性。[2][3]

適合性

肾素检测试剂盒提供了一种方便、简单的检测方法,适于筛查多种样品中的肾素活性,或用于筛选肾素抑制剂。

原則

肾素的活性是通过含有荧光猝灭剂的专有荧光共振能量转移(FRET)肽测定的。肾素切割肽会产生一种荧光产物(λex = 540/λem = 590 nm)。该测定的灵敏度约是基于 EDANS/DABCYL 的测定的 50 倍。

儲存類別代碼

10 - Combustible liquids

水污染物質分類(WGK)

WGK 2

閃點(°F)

Not applicable

閃點(°C)

Not applicable


從最近期的版本中選擇一個:

分析證明 (COA)

Lot/Batch Number

未看到正確版本?

如果您需要一個特定的版本,您可以透過批號來尋找特定憑證。

已經擁有該產品?

您可以在文件庫中找到最近購買的產品相關文件。

存取文件庫

Árpád Kovács et al.
American journal of physiology. Heart and circulatory physiology, 310(11), H1671-H1682 (2016-04-10)
Hypertension (HTN) is a major risk factor for heart failure. We investigated the influence of HTN on cardiac contraction and relaxation in transgenic renin overexpressing rats (carrying mouse Ren-2 renin gene, mRen2, n = 6). Blood pressure (BP) was measured.
Aliskiren decreases oxidative stress and angiogenic markers in retinal pigment epithelium cells.
Sim?o S, et al.
Angiogenesis, 20(1), 175-181 (2017)
The hormone FGF21 stimulates water drinking in response to ketogenic diet and alcohol.
Song P, et al.
Cell Metabolism, 27(6), 1338-1347 (2018)
Caroline G Shimoura et al.
Journal of applied physiology (Bethesda, Md. : 1985), 128(5), 1329-1337 (2020-04-03)
Acute intermittent hypoxia (AIH) triggers sympathetic long-term facilitation (sLTF), a progressive increase in sympathetic nerve activity (SNA) linked to central AT1 receptor (AT1R) activation by circulating angiotensin II (ANG II). Here, we investigated AIH activation of the peripheral renin-angiotensin system
Iselin Vildmyren et al.
Nutrients, 10(12) (2018-11-25)
Hypertension is the leading risk factor for cardiovascular disease, and prevention of high blood pressure through diet and lifestyle should be a preferred approach. High intake of fish is associated with lower blood pressure, possibly mediated through the proteins since

Questions

1–2 of 2 Questions  
  1. Species that this assay works on?

    1 answer
    1. Although the standard that has been tested is recombinant human renin, theoretically the kit should be suitable for all other species.

      Helpful?

  2. Does the kit MAK157 contain any Renin inhibitor? If so, how much Renin inhibitor should be added, and at what step of the assay should it be added in order to determine the Renin activity?

    1 answer
    1. The kit MAK157 does not contain any Renin inhibitor. To confirm the activity using this kit, researchers can use a RENIN INHIBITOR separately.The amount of inhibitor to use and the step to use the Renin inhibitor can be referred to from published literature.

      Helpful?

Reviews

1 of 1 reviewers received a sample product or took part in a promotion

Active Filters

  1. Oxford
    • Review 1
    • Vote 1
    2 out of 5 stars.

    Kit instructions misleading - be careful

    Kit provides you with 10mL assay buffer. At least 1.87mL needed for making standards. 5mL needed for making substrate. Leaves you with 3.13mL for diluting samples. If your samples need a lot of diluting this is insufficient. I did not find the customer service suggestion of using water to dilute my samples to be appropriate or helpful. They could instead just provide sufficient reagent. God help you if you want to run the assay twice, with two sets of standards, further depleting the assay buffer stock.

    Helpful?

    1. Response from MilliporeSigma:

      Thank you for taking the time to leave a review! We are sorry to hear that your experience did not meet expectations. We have passed on your feedback to the product manager, and would like to learn more about your experience to see if there is anything we can do to improve this assay kit. When you have a moment, please contact us by visiting https://www.sigmaaldrich.com/support/customer-support and submit a Report Product Issue ticket. We lo]ok forward to hearing from you soon!

我們的科學家團隊在所有研究領域都有豐富的經驗,包括生命科學、材料科學、化學合成、色譜、分析等.