跳轉至內容
Merck
全部照片(4)

重要文件

MAK064

Sigma-Aldrich

乳酸检测试剂盒

sufficient for 100 colorimetric or fluorometric tests

同義詞:

乳酸检测试剂盒

登入查看組織和合約定價


About This Item

分類程式碼代碼:
12161503
NACRES:
NA.84
暫時無法取得訂價和供貨情況

用途

sufficient for 100 colorimetric or fluorometric tests

應用

cosmetics
food and beverages

檢測方法

colorimetric
fluorometric

相關疾病

endocrinological disorders, diabetes; cancer

儲存溫度

−20°C

一般說明

L(+)-乳酸是一种通过乳酸脱氢酶的作用而在动物中形成的代谢化合物。乳酸是在增殖的细胞中以及在诸如运动的无氧条件下产生的。 异常高浓度的乳酸与癌症、糖尿病和乳酸酸中毒等病理状况有关。L(+)-乳酸是在人体中间代谢中所形成的乳酸的主要立体异构体,并以约1-2 mmol/L的水平存在于血液中。该试剂盒可提供一种简便的方法用于在生物学样本中进行L(+)-乳酸的检测。无需对样本进行预处理或纯化。

應用

乳酸检测试剂盒已用于确定样本中乳酸的浓度。[1][2]

適合性

适合用于在培养基、发酵培养基、血液和细胞中检测L(+)-乳酸。

原則

在该测定中,乳酸的浓度是通过一种酶检测而被测定的,其可产生与存在的乳酸成比例的比色(570nm)/荧光测定(λex = 535 nm/λem = 587 nm)产物。该试剂盒的常见灵敏度水平在0.001-10 mM之间。

取代透過

象形圖

Health hazard

訊號詞

Danger

危險聲明

危險分類

Resp. Sens. 1 - Skin Sens. 1

儲存類別代碼

10 - Combustible liquids

閃點(°F)

188.6 °F - closed cup

閃點(°C)

87 °C - closed cup


從最近期的版本中選擇一個:

分析證明 (COA)

Lot/Batch Number

未看到正確版本?

如果您需要一個特定的版本,您可以透過批號來尋找特定憑證。

已經擁有該產品?

您可以在文件庫中找到最近購買的產品相關文件。

存取文件庫

Min Xu et al.
Cellular physiology and biochemistry : international journal of experimental cellular physiology, biochemistry, and pharmacology, 47(1), 151-160 (2018-05-16)
Poor response to chemotherapy leads to the relapse and metastatic progression of tumors. Reprogrammed glucose metabolism is one of the important hallmarks of cancer that facilitates cancer cell survival, proliferation and chemoresistance. However, the precise fate of glucose metabolism and
Prabha Shrestha et al.
PLoS pathogens, 13(9), e1006628-e1006628 (2017-09-19)
Primary effusion lymphoma (PEL) is an aggressive B-cell lymphoma with poor prognosis caused by Kaposi's sarcoma-associated herpesvirus (KSHV). Previous studies have revealed that HIF-1α, which mediates much of the cellular response to hypoxia, plays an important role in life cycle
Bibi Uhre Nielsen et al.
PloS one, 15(9), e0238524-e0238524 (2020-09-12)
Markers of lung inflammation measured directly in expectorated sputum have the potential of improving the timing of antibiotic treatment in cystic fibrosis (CF). L-Lactate might be a marker of inflammation, as it is produced from glucose by polymorphonuclear neutrophils (PMNs)
Annasofia Anemone et al.
International journal of oncology, 51(2), 498-506 (2017-07-18)
Dichloroacetate (DCA) can reverse the glycolytic phenotype that is responsible of increased lactate production and extracellular pH acidification in cancer cells. Magnetic resonance imaging-chemical exchange saturation transfer (MRI-CEST) pH mapping is a novel non-invasive imaging approach that can measure in vivo
Cardiac STAT3 Deficiency Impairs Contractility and Metabolic Homeostasis in Hypertension.
Altara R, et al.
Frontiers in Pharmacology, 7, 436-436 (2016)

文章

沃伯格效應會增強腫瘤細胞中葡萄糖到乳酸的轉換,而不受氧氣水平的影響;自 1924 年起就開始影響癌症新陳代謝。

Warburg effect enhances glucose to lactate conversion in tumor cells, regardless of oxygen levels; impacting cancer metabolism since 1924.

Questions

1–9 of 9 Questions  
  1. How is shipping temperature determined? And how is it related to the product storage temperature?

    1 answer
    1. Products may be shipped at a different temperature than the recommended long-term storage temperature. If the product quality is sensitive to short-term exposure to conditions other than the recommended long-term storage, it will be shipped on wet or dry-ice. If the product quality is NOT affected by short-term exposure to conditions other than the recommended long-term storage, it will be shipped at ambient temperature. As shipping routes are configured for minimum transit times, shipping at ambient temperature helps control shipping costs for our customers. For more information, please refer to the Storage and Transport Conditions document: https://www.sigmaaldrich.com/deepweb/assets/sigmaaldrich/marketing/global/documents/316/622/storage-transport-conditions-mk.pdf

      Helpful?

  2. How can I determine the shelf life / expiration / retest date of this product?

    1 answer
    1. If this product has an expiration or retest date, it will be shown on the Certificate of Analysis (COA, CofA). If there is no retest or expiration date listed on the product's COA, we do not have suitable stability data to determine a shelf life. For these products, the only date on the COA will be the release date; a retest, expiration, or use-by-date will not be displayed.
      For all products, we recommend handling per defined conditions as printed in our product literature and website product descriptions. We recommend that products should be routinely inspected by customers to ensure they perform as expected.
      For products without retest or expiration dates, our standard warranty of 1 year from the date of shipment is applicable.
      For more information, please refer to the Product Dating Information document: https://www.sigmaaldrich.com/deepweb/assets/sigmaaldrich/marketing/global/documents/449/386/product-dating-information-mk.pdf

      Helpful?

  3. What is the formula for the MAK064D Lactate standard?

    1 answer
    1. The standard provided in the MAK064-1KT Lactate Assay Kit is L-Lactic acid sodium salt (CAS 867-56-1) dissolved in water. It contains no other components or cofactors.

      Helpful?

  4. Since the L-(+)-Lactate standard is not a pure solution of sodium L-(+)-Lactate in water or buffer, which are the cofactors present in the standard?

    1 answer
    1. The standard provided in this kit is L-Lactic acid sodium salt (CAS 867-56-1) dissolved in water. There are no other components or cofactors present in the standard.

      Helpful?

  5. What is the concentration range of lactate for this? The description says typical sensitivity is 0.001 - 10 mM, but in the product info the standard curve for colorimetric detection appears to go to a max. concentration of 0.0002µM (10nmol in 50µL sample)

    1 answer
    1. The lower limit of detection is calculated by dividing the lowest concentration standard by the maximum sample volume. The higher limit of detection is determined by dividing the highest concentration standard by the minimum sample volume.

      For the higher limit of detection, take the 10 nmol standard and divide by 1 uL to get 10 mM. For the lower limit of detection, take 0.02 nmol and divide by 50 uL to get 0.0004 mM. We have reached out to our vendor to discuss the range calculation further, as it seems there is some conflicting information.

      Helpful?

  6. Can this kit be used on conditioned media containing phenol red?

    1 answer
    1. If the sample being measured is the cell culture supernatant, the required volume is 20 uL. This is diluted with a total volume of 100 uL of the various kit reagents. The presence of phenol red may impact the results. It would be up to the end user to determine suitability.

      Helpful?

  7. On which enzymatic reaction is this kit based? Does pyruvate in the sample interfere with the assay?

    1 answer
    1. This kit utilizes lactate oxidase to measure lactate. In sufficient amounts pyrivate may impact the results. This can be corrected by subtracting any background from the blank value. See page 3 in the kit protocol provided in the link below:
      https://www.sigmaaldrich.com/deepweb/assets/sigmaaldrich/product/documents/411/763/mak064bul.pdf

      Helpful?

  8. What is the Department of Transportation shipping information for this product?

    1 answer
    1. Transportation information can be found in Section 14 of the product's (M)SDS.To access the shipping information for this material, use the link on the product detail page for the product.

      Helpful?

  9. Can I make up my own Lactate standard to use with Product MAK064, Lactate Assay kit?

    1 answer
    1. Unfortunately, no. If you run the 100 mM L-(+)-Lactate standard (MAK064D) that comes with the kit, you should get good results. However, if you just use, for example, a solution of sodium L-(+)-lactate dissolved in water or buffer, you probably won't get good results. There are cofactors present in biological samples and in the L-(+)-Lactate standard that comes with the kit (which is not a pure solution of sodium L-(+)-Lactate in water or buffer). If such a "homemade" standard solution were to be spiked with a biological sample or the kit standard, the calculations would be more complicated, but the assay should work.

      Helpful?

Reviews

No rating value

Active Filters

我們的科學家團隊在所有研究領域都有豐富的經驗,包括生命科學、材料科學、化學合成、色譜、分析等.

聯絡技術服務