跳轉至內容
Merck
全部照片(1)

重要文件

GE28-9924-74

HiScreen Capto Blue

Cytiva 28-9924-74, pack of 1 column

登入查看組織和合約定價


About This Item

分類程式碼代碼:
23151817
NACRES:
NA.56
暫時無法取得訂價和供貨情況

包裝

pack of 1 column

製造商/商標名

Cytiva 28-9924-74

參數

1.2 ml/min - 2.3 ml/min flow rate
44 psi

床尺寸

7.7 mm × 100 mm

床體積

4.7 mL

容量

~25 mg binding capacity(human serum albumin/ml medium)

儲存溫度

2-8°C

一般說明

HiScreen™ columns are part of the process development platform available from Cytiva. The columns are prepacked with a range of BioProcess chromatography media (resins) and designed for method optimization and parameter screening. HiScreen™ columns have small bed volumes (4.7 ml), reducing the cost of sample and buffer consumption. The media used in HiScreen™ columns are also available in other prepacked formats and as bulk packs, for all scales of work from development and pilot studies to routine production.

應用

HiScreen Capto Blue is prepacked with the base matrix Capto to which Cibacron Blue 3G is covalently bound via a hydrophilic spacer immobilized with a stable amine bond. Capto Blue is highly chemically stable and has a more rigid Agarose base matrix than Blue Sepharose 6 Fast Flow. This allows the use of faster flow rates and larger sample volumes, leading to higher throughput and improved process economy. The application area is the same as for Blue Sepharose Fast FLow (e.g., purification of albumin, enzymes including NAD+ and NADP+, coagulation factors, interferons, and related Proteins). The main benefit of Capto Blue compared to Blue Sepharose 6 Fast FLow is its improved chemical stability provided with a new coupling chemistry involving a spacer arm. It tolerates repeated cleaning-in-place and sanitization at both high and Low pH as well as autoclaving. Also the leakage of Cibacron Blue is reduced as compared to Blue Sepharose 6 Fast Flow.

特點和優勢

  • Prepacked with Capto Blue
  • Excellent for method optimization and parameter screening due to the 10 cm bed height
  • Easily connected in series to achieve 20 cm bed height
  • Small bed volume for fast results and minimal sample/buffer consumption
  • Reproducible results, scalable to BioProcess columns packed with the same media using the same flow velocity

儲存和穩定性

Please be aware this product may be shipped 90 days before the expiration date. For more information on the batch specific expiration date, please contact technical service.

分析報告

To view the Certificate of Analysis for this product, please visit www.cytiva.com.

其他說明

The pressure over the packed bed varies depending on a range of parameters such as the characteristics of the chromatography medium and the column tubing used.

法律資訊

Capto is a trademark of Cytiva
HiScreen is a trademark of Cytiva
Sepharose is a trademark of Cytiva

象形圖

Flame

訊號詞

Warning

危險聲明

儲存類別代碼

3 - Flammable liquids


從最近期的版本中選擇一個:

分析證明 (COA)

Lot/Batch Number

It looks like we've run into a problem, but you can still download Certificates of Analysis from our 文件 section.

如果您需要協助,請聯絡 客戶支援

已經擁有該產品?

您可以在文件庫中找到最近購買的產品相關文件。

存取文件庫

文章

本頁顯示如何在抗體親和層析中轉換流速和體積流速。

This page shows how to convert between flow velocity and volumetric flow rate in affinity chromatography of antibodies.

條款

This page shows how purify or remove albumin with Blue Sepharose and Capto Blue from Cytiva.

相關內容

This page shows how purify or remove albumin with Blue Sepharose and Capto Blue from GE Healthcare.

我們的科學家團隊在所有研究領域都有豐富的經驗,包括生命科學、材料科學、化學合成、色譜、分析等.

聯絡技術服務