全部照片(2)
About This Item
經驗公式(希爾表示法):
C20D4H22O4
CAS號碼:
分子量::
334.44
MDL號碼:
分類程式碼代碼:
41116107
PubChem物質ID:
NACRES:
NA.24
暫時無法取得訂價和供貨情況
推薦產品
等級
analytical standard
品質等級
產品線
PESTANAL®
儲存期限
limited shelf life, expiry date on the label
技術
HPLC: suitable
gas chromatography (GC): suitable
應用
agriculture
environmental
形式
neat
質量偏移
M+4
SMILES 字串
[2H]c1c([2H])c([2H])c(C(=O)OC2CCCCC2)c(c1[2H])C(=O)OC3CCCCC3
InChI
1S/C20H26O4/c21-19(23-15-9-3-1-4-10-15)17-13-7-8-14-18(17)20(22)24-16-11-5-2-6-12-16/h7-8,13-16H,1-6,9-12H2/i7D,8D,13D,14D
InChI 密鑰
VOWAEIGWURALJQ-ZZRPVTOQSA-N
一般說明
Dicyclohexyl phthalate-3,4,5,6-d4 is a deuterated phthalate ester analog, wherein 3, 4, 5, and 6 protons of the aryl ring are replaced by deuterium.
應用
Dicyclohexyl phthalate-3,4,5,6-d4 can be used as a deuterated internal standard to determine the levels of phthalates in aquatic matrices by ultra-high-performance liquid chromatography coupled to hybrid Q-Orbitrap mass spectrometry.[1]
Isotope-labeled compounds are increasingly used in isotope dilution mass spectrometry (IDMS) for the quantitative analysis of pesticides. The major advantage of using this technique is that the isotope-labeled compounds have nearly the same physical properties as their non-labeled counterpart analogs, and thus show identical behavior during the workup and sample preparation process. This helps in overcoming the problems of matrix effects generally encountered in the usual LC-MS/GC-MS analysis potentially resulting in biased results. By spiking the sample before workup with its isotope labeled analog, the loss of analyte that leads to matrix effects can be determined and compensated.
Isotope-labeled compounds are increasingly used in isotope dilution mass spectrometry (IDMS) for the quantitative analysis of pesticides. The major advantage of using this technique is that the isotope-labeled compounds have nearly the same physical properties as their non-labeled counterpart analogs, and thus show identical behavior during the workup and sample preparation process. This helps in overcoming the problems of matrix effects generally encountered in the usual LC-MS/GC-MS analysis potentially resulting in biased results. By spiking the sample before workup with its isotope labeled analog, the loss of analyte that leads to matrix effects can be determined and compensated.
Refer to the product′s Certificate of Analysis for more information on a suitable instrument technique. Contact Technical Service for further support.
法律資訊
PESTANAL is a registered trademark of Merck KGaA, Darmstadt, Germany
訊號詞
Danger
危險聲明
危險分類
Aquatic Chronic 3 - Repr. 1B - Skin Sens. 1
儲存類別代碼
6.1C - Combustible acute toxic Cat.3 / toxic compounds or compounds which causing chronic effects
水污染物質分類(WGK)
WGK 1
閃點(°F)
356.0 - 374.0 °F
閃點(°C)
180 - 190 °C
個人防護裝備
Eyeshields, Gloves
Targeted quantification and untargeted screening of alkylphenols, bisphenol A and phthalates in aquatic matrices using ultra-high-performance liquid chromatography coupled to hybrid Q-Orbitrap mass spectrometry
Huysman S, et al.
Analytica Chimica Acta, 1049, 141-151 (2019)
Active Filters
我們的科學家團隊在所有研究領域都有豐富的經驗,包括生命科學、材料科學、化學合成、色譜、分析等.
聯絡技術服務