暫時無法取得訂價和供貨情況
推薦產品
等級
matrix substance for MALDI-MS
品質等級
化驗
≥99.5% (HPLC)
形狀
powder
mp
156-158 °C (lit.)
溶解度
dioxane: 50 mg/mL, clear
正離子痕跡
Ca: ≤10 mg/kg
Cd: ≤5 mg/kg
Co: ≤5 mg/kg
Cr: ≤5 mg/kg
Cu: ≤5 mg/kg
Fe: ≤5 mg/kg
K: ≤50 mg/kg
Mg: ≤5 mg/kg
Mn: ≤5 mg/kg
Na: ≤50 mg/kg
Ni: ≤5 mg/kg
Pb: ≤5 mg/kg
Zn: ≤5 mg/kg
SMILES 字串
CC(=O)c1c(O)cccc1O
InChI
1S/C8H8O3/c1-5(9)8-6(10)3-2-4-7(8)11/h2-4,10-11H,1H3
InChI 密鑰
YPTJKHVBDCRKNF-UHFFFAOYSA-N
尋找類似的產品? 前往 產品比較指南
訊號詞
Warning
危險聲明
危險分類
Eye Irrit. 2 - Skin Irrit. 2 - STOT SE 3
標靶器官
Respiratory system
儲存類別代碼
11 - Combustible Solids
水污染物質分類(WGK)
WGK 3
閃點(°F)
Not applicable
閃點(°C)
Not applicable
個人防護裝備
dust mask type N95 (US), Eyeshields, Gloves
Giancarlo Cravotto et al.
Chemical & pharmaceutical bulletin, 52(10), 1171-1174 (2004-10-07)
Squalene-hopene cyclase (SHC) is a useful model enzyme for predicting molecular interactions with oxidosqualene cyclase (OSC). Structure--activity relationships were investigated for numerous coumarin-derived inhibitors of SHC, and structural simplifications are suggested. Both umbelliferone and 2,4-dihydroxyacetophenone provide convenient starting nuclei for
Johan Jacksén et al.
Analytical biochemistry, 425(1), 18-20 (2012-03-13)
Matrix-assisted laser desorption/ionization mass spectrometry (MALDI-MS) is widely used for analysis of macromolecules like peptides and proteins. The analysis procedure is generally simple but must be adapted to the characteristics of the analytes. Therefore, specific matrices suitable for, e.g., hydrophobic
Ana Maria Balan et al.
European journal of medicinal chemistry, 44(5), 2275-2279 (2008-08-02)
Herein we report a feasible study concerning syntheses, structure and antimicrobial activity of some new diazinium salts with dihydroxyacetophenone skeleton. A fast, general, environmentally friendly, and facile method for preparation of diazinium salts under microwave and ultrasounds irradiation is presented.
Erica L McJimpsey et al.
Journal of the American Society for Mass Spectrometry, 19(3), 315-324 (2007-12-25)
The Bioaerosol Mass Spectrometry (BAMS) system was developed for the real-time detection and identification of biological aerosols using laser desorption ionization. Greater differentiation of particle types is desired; consequently MALDI techniques are being investigated. The small sample size ( approximately
T A Smith et al.
The Annals of occupational hygiene, 39(2), 235-240 (1995-04-01)
Sodium cromoglycate is manufactured by a seven-stage synthetic process. There has been no previous documentation of toxicological effects of the intermediate compounds in its synthesis. This paper describes the health effects of acute exposure to the intermediates on the skin
Active Filters
我們的科學家團隊在所有研究領域都有豐富的經驗,包括生命科學、材料科學、化學合成、色譜、分析等.
聯絡技術服務