跳轉至內容
Merck

KHVES3THH1

Millipore

Opticap 无菌 XLT 30 Millipore Express SHR 带预滤器 0.5/0.1 µm 5/8 in. HB

sterile, Opticap® XLT 30, inlet connection diam. 5/8 in., pore size 0.5/0.1 μm, cartridge nominal length 30 in. (75 cm)

同義詞:

Millipore Express® SHRP Opticap® XLT 囊式

登入查看組織和合約定價


About This Item

分類程式碼代碼:
23151806

材料

polyester support
polyethersulfone
polypropylene (gamma-stable)
polypropylene housing
polypropylene vent cap (Gamma stable)
polysulfone
silicone seal

品質等級

法律遵循

meets FDA Indirect Food Additive requirements cited in 21 CFR 177-182 (all component materials)

無菌

irradiated
sterile

產品線

Opticap® XLT 30

特點

hydrophilic

製造商/商標名

Millipore Express®

參數

≤91.2 mL/min air diffusion at 3.45 bar (50 psig) and 23 °C (in water)
1.0 bar max. differential pressure (15 psid) at 80 °C (Forward)
1.0 bar max. inlet pressure (15 psi) at 80 °C
100 psi max. differential pressure (6.9 bar) (intermittent)
2.1 bar max. differential pressure (30 psid) at 25 °C (Reverse; intermittent)
2.75 bar max. inlet pressure (40 psi) at 60 °C
25 °C max. inlet temp.
5.5 bar max. differential pressure (80 psid) at 25 °C (Forward)
5.5 bar max. inlet pressure (80 psi) at 25 °C
6.9 bar max. differential pressure (100 psid) at 25 °C (Forward; intermittent)
6.9 bar max. inlet pressure (100 psi) at 25 °C (intermittent)
80 psi max. differential pressure (5.5 bar) (continuous)
80 psig max. inlet pressure

技術

sterile filtration: suitable

長度

87.1 cm (34.3 in.)

柱標稱長度

30 in. (75 cm)

直徑

19.8 cm (7.8 in.)

過濾面積

1.62 m2

入口接頭直徑

5/8 in.

入口到出口寬度

19.8 cm (7.8 in.)

出口接頭直徑

5/8 in.

雜質

≤0.25 EU/mL bacterial endotoxins (LAL test, Aqueous extraction)
<0.25 EU/mL USP bacterial endotoxins (LAL test, sample aqueous extraction)

基質

Millipore Express® SHR (w/Prefilter)

pore size

0.5/0.1 μm pore size

起泡點

≥2586 mbar (37.5 psig), nitrogen with 70/30% IPA/water at 23 °C

接頭

1/4 in. drain/vent hose barb (with double O-ring Seal)
inlet hose barb
outlet hose barb
(16 mm (5?8 in.) Hose Barb Inlet and Outlet)

一般說明

Device Configuration: 取样皿滤膜
T-line/Gauge Port: T-line

包裝

double Easy-Open bag

其他說明

These products are manufactured in a facility which adheres to FDA Good Manufacturing Practices.
Directions for Use

  • Organism Retention: Microorganism
  • Mode of Action: Filtration (size exclusion)
  • Application: BioProcessing
  • Intended Use: Reduction or removal of microorganism/bioburden
  • Instructions for Use: Please refer installation section of OPTICAP® XL Capsules and OPTICAP® XLT Capsules user guide
  • Storage Statement: Store in dry location
  • Disposal Statement: Dispose of in accordance with applicable federal, state and local regulations.

準備報告

Sterilization Method
3 autoclave cycles of 60 min @ 123 °C; not in-line steam sterilizable
This product was manufactured with a Millipore Express® membrane which meets the criteria for a "non-fiber releasing" filter as defined in 21 CFR 210.3 (b) (6).

分析報告

Bacterial Retention
Samples were quantitatively retentive of a minimum Brevundimonas diminuta challenge concentration of 1 x 10⁷ CFU/cm² using ASTM® F838 methodology.
TOC/Conductivity
After sterilization and a controlled water flush of 60 L, samples exhibited less than 500 ppb TOC per USP <64> and less than 1.3 µS/cm per USP <64> at 25 °C.
Will meet the USP Oxidizable Substances Test requirements after a water flush of ≥6 L

法律資訊

ASTM is a registered trademark of American Society for Testing and Materials
MILLIPORE EXPRESS is a registered trademark of Merck KGaA, Darmstadt, Germany
OPTICAP is a registered trademark of Merck KGaA, Darmstadt, Germany

未找到適合的產品?  

試用我們的產品選擇工具.


分析證明 (COA)

輸入產品批次/批號來搜索 分析證明 (COA)。在產品’s標籤上找到批次和批號,寫有 ‘Lot’或‘Batch’.。

已經擁有該產品?

您可以在文件庫中找到最近購買的產品相關文件。

存取文件庫

我們的科學家團隊在所有研究領域都有豐富的經驗,包括生命科學、材料科學、化學合成、色譜、分析等.