跳轉至內容
Merck
全部照片(1)

重要文件

E-058

Supelco

表睾酮 溶液

1.0 mg/mL in acetonitrile, ampule of 1 mL, certified reference material, Cerilliant®

登入查看組織和合約定價


About This Item

經驗公式(希爾表示法):
C19H28O2
CAS號碼:
分子量::
288.42
EC號碼:
MDL號碼:
分類程式碼代碼:
41116107
PubChem物質ID:
NACRES:
NA.24
暫時無法取得訂價和供貨情況

等級

certified reference material

品質等級

形狀

liquid

特點

Snap-N-Spike®/Snap-N-Shoot®

包裝

ampule of 1 mL

製造商/商標名

Cerilliant®

濃度

1.0 mg/mL in acetonitrile

技術

gas chromatography (GC): suitable
liquid chromatography (LC): suitable

應用

clinical testing

形式

single component solution

儲存溫度

2-8°C

SMILES 字串

C[C@]12CC[C@H]3[C@@H](CCC4=CC(=O)CC[C@]34C)[C@@H]1CC[C@H]2O

InChI

1S/C19H28O2/c1-18-9-7-13(20)11-12(18)3-4-14-15-5-6-17(21)19(15,2)10-8-16(14)18/h11,14-17,21H,3-10H2,1-2H3/t14-,15-,16-,17+,18-,19-/m0/s1

InChI 密鑰

MUMGGOZAMZWBJJ-KZYORJDKSA-N

一般說明

表睾酮是激素睾酮的立体异构体。表睾酮通常用于在运动药物测试中非法掩盖高睾酮水平。这种经过认证的Snap-N-Spike®溶液适用于运动测试、尿液药物测试或法医分析的LC/MS或GC/MS应用。

法律資訊

CERILLIANT is a registered trademark of Merck KGaA, Darmstadt, Germany
Snap-N-Shoot is a registered trademark of Cerilliant Corporation
Snap-N-Spike is a registered trademark of Merck KGaA, Darmstadt, Germany

相關產品

產品號碼
描述
訂價

象形圖

FlameExclamation mark

訊號詞

Danger

危險分類

Acute Tox. 4 Dermal - Acute Tox. 4 Inhalation - Acute Tox. 4 Oral - Eye Irrit. 2 - Flam. Liq. 2

儲存類別代碼

3 - Flammable liquids

水污染物質分類(WGK)

WGK 2

閃點(°F)

35.6 °F - closed cup

閃點(°C)

2 °C - closed cup


從最近期的版本中選擇一個:

分析證明 (COA)

Lot/Batch Number

It looks like we've run into a problem, but you can still download Certificates of Analysis from our 文件 section.

如果您需要協助,請聯絡 客戶支援

已經擁有該產品?

您可以在文件庫中找到最近購買的產品相關文件。

存取文件庫

Tomasz Bączek et al.
TheScientificWorldJournal, 2012, 268120-268120 (2012-04-27)
The validated micellar electrokinetic chromatography (MEKC) was proposed for the determination of five steroid hormones in human urine samples. That technique allowed for the separation and quantification of cortisol, cortisone, corticosterone, testosterone, and epitestosterone and was sensitive enough to detect
Andreu Fabregat et al.
Steroids, 76(12), 1367-1376 (2011-07-26)
The screening of testosterone misuse in the doping control field is normally performed by the measurement of the ratio between the concentrations of testosterone and epitestosterone excreted as glucuronides (T/E). Despite the satisfactory results obtained with this approach, the measurement
Ruth I Wood et al.
Hormones and behavior, 61(1), 147-155 (2011-10-11)
Testosterone and other anabolic-androgenic steroids enhance athletic performance in men and women. As a result, exogenous androgen is banned from most competitive sports. However, due to variability in endogenous secretion, and similarities with exogenous testosterone, it has been challenging to
[Introduction of genetic analysis can provide us with safer doping tests. Large variation in androgen turnover creates problems in current tests].
Anders Rane et al.
Lakartidningen, 109(29-31), 1347-1349 (2012-08-24)
Kang Mi Lee et al.
Rapid communications in mass spectrometry : RCM, 25(16), 2261-2267 (2011-07-15)
A simple and accurate liquid chromatography/tandem mass spectrometry (LC/MS/MS) method has been developed and validated for the quantitative determination of ephedrine, pseudoephedrine, methylephedrine, cathine, salbutamol, morphine and epitestosterone in human urine. Urine samples were spiked with internal standard and diluted

Questions