跳转至内容
Merck

MAK157

Sigma-Aldrich

肾素检测试剂盒

Renin Assay Kit
1 of 1 reviewers received a sample product or took part in a promotion

sufficient for 100 fluorometric tests

别名:

肾素检测试剂盒

登录查看公司和协议定价

选择尺寸

1 KIT
$476.00

$476.00


请联系客服了解存货情况

获取大包装报价

选择尺寸

变更视图
1 KIT
$476.00

About This Item

UNSPSC代码:
12161503
NACRES:
NA.84

$476.00


请联系客服了解存货情况

获取大包装报价

用途

sufficient for 100 fluorometric tests

检测方法

fluorometric

相关疾病

cardiovascular diseases

储存温度

−20°C

基因信息

human ... REN(5972)
rat ... REN(24715)

一般描述

肾素,也称为血管紧张素原酶,是一种天冬氨酰蛋白酶,可切割血管紧张素原,形成血管紧张素 I,这是肾素-血管紧张素系统(RAS)的初始和限速步骤。该系统在血压和体液平衡的调节中起关键作用。由于血管收缩和液体潴留增加,肾素活性增加可导致高血压。肾素抑制剂可用于高血压的治疗。[1]

应用

肾素检测试剂盒已用于测定肾素的活性。[2][3]

适用性

肾素检测试剂盒提供了一种方便、简单的检测方法,适于筛查多种样品中的肾素活性,或用于筛选肾素抑制剂。

原理

肾素的活性是通过含有荧光猝灭剂的专有荧光共振能量转移(FRET)肽测定的。肾素切割肽会产生一种荧光产物(λex = 540/λem = 590 nm)。该测定的灵敏度约是基于 EDANS/DABCYL 的测定的 50 倍。

储存分类代码

10 - Combustible liquids

WGK

WGK 2

闪点(°F)

Not applicable

闪点(°C)

Not applicable


历史批次信息供参考:

分析证书(COA)

Lot/Batch Number

没有发现合适的版本?

如果您需要特殊版本,可通过批号或批次号查找具体证书。

已有该产品?

在文件库中查找您最近购买产品的文档。

访问文档库

The hormone FGF21 stimulates water drinking in response to ketogenic diet and alcohol.
Song P, et al.
Cell Metabolism, 27(6), 1338-1347 (2018)
Aliskiren decreases oxidative stress and angiogenic markers in retinal pigment epithelium cells.
Sim?o S, et al.
Angiogenesis, 20(1), 175-181 (2017)
Árpád Kovács et al.
American journal of physiology. Heart and circulatory physiology, 310(11), H1671-H1682 (2016-04-10)
Hypertension (HTN) is a major risk factor for heart failure. We investigated the influence of HTN on cardiac contraction and relaxation in transgenic renin overexpressing rats (carrying mouse Ren-2 renin gene, mRen2, n = 6). Blood pressure (BP) was measured.
Caroline G Shimoura et al.
Journal of applied physiology (Bethesda, Md. : 1985), 128(5), 1329-1337 (2020-04-03)
Acute intermittent hypoxia (AIH) triggers sympathetic long-term facilitation (sLTF), a progressive increase in sympathetic nerve activity (SNA) linked to central AT1 receptor (AT1R) activation by circulating angiotensin II (ANG II). Here, we investigated AIH activation of the peripheral renin-angiotensin system
Yong Zhang et al.
Frontiers in physiology, 13, 876777-876777 (2022-05-20)
The therapeutic potential of 2-Methoxyestradiol (2ME2) is evident in cardiovascular disease. Our laboratory has previously demonstrated the mechanism involved in the 2ME2 regulation of angiotensin type 1 receptor (AT1R) in vitro. However, 2ME2 regulation of angiotensin receptors and its effects

Questions

1–2 of 2 Questions  
  1. Species that this assay works on?

    1 answer
    1. Although the standard that has been tested is recombinant human renin, theoretically the kit should be suitable for all other species.

      Helpful?

  2. Does the kit MAK157 contain any Renin inhibitor? If so, how much Renin inhibitor should be added, and at what step of the assay should it be added in order to determine the Renin activity?

    1 answer
    1. The kit MAK157 does not contain any Renin inhibitor. To confirm the activity using this kit, researchers can use a RENIN INHIBITOR separately.The amount of inhibitor to use and the step to use the Renin inhibitor can be referred to from published literature.

      Helpful?

Reviews

1 of 1 reviewers received a sample product or took part in a promotion

Active Filters

  1. Oxford
    • Review 1
    • Vote 1
    2 out of 5 stars.

    Kit instructions misleading - be careful

    Kit provides you with 10mL assay buffer. At least 1.87mL needed for making standards. 5mL needed for making substrate. Leaves you with 3.13mL for diluting samples. If your samples need a lot of diluting this is insufficient. I did not find the customer service suggestion of using water to dilute my samples to be appropriate or helpful. They could instead just provide sufficient reagent. God help you if you want to run the assay twice, with two sets of standards, further depleting the assay buffer stock.

    Helpful?

    1. Response from MilliporeSigma:

      Thank you for taking the time to leave a review! We are sorry to hear that your experience did not meet expectations. We have passed on your feedback to the product manager, and would like to learn more about your experience to see if there is anything we can do to improve this assay kit. When you have a moment, please contact us by visiting https://www.sigmaaldrich.com/support/customer-support and submit a Report Product Issue ticket. We lo]ok forward to hearing from you soon!

我们的科学家团队拥有各种研究领域经验,包括生命科学、材料科学、化学合成、色谱、分析及许多其他领域.

联系客户支持