推荐产品
產品線
BioReagent
化驗
≥97.0% (HPLC)
形狀
crystals
溶解度
DMSO: soluble
chloroform: soluble
螢光
λex 433 nm; λem 500 nm in 50 mM Tris pH 8.0; 40% glycerol
適合性
suitable for fluorescence
SMILES 字串
N#C\C(=C/c1cc2CCCN3CCCc(c1)c23)C#N
InChI
1S/C16H15N3/c17-10-13(11-18)7-12-8-14-3-1-5-19-6-2-4-15(9-12)16(14)19/h7-9H,1-6H2
InChI 密鑰
LROAUBRDKLVBCP-UHFFFAOYSA-N
包裝
无底玻璃瓶。内容物在插入式融锥内。
其他說明
作为荧光探针,用于结合蛋白质等,通过减少自由旋转来增加量子产率;吸收波长在~450nm处,发射波长在480-505nm处(溶剂dep.)
儲存類別代碼
11 - Combustible Solids
水污染物質分類(WGK)
WGK 3
閃點(°F)
Not applicable
閃點(°C)
Not applicable
個人防護裝備
dust mask type N95 (US), Eyeshields, Gloves
其他客户在看
Pharmaceutical research, 27(2), 314-326 (2009-12-31)
The aim was to evaluate fluorescent molecular rotors (DCVJ and CCVJ), which are mainly sensitive to viscosity, for the characterization of polysorbate-containing IgG formulations and compare them to the polarity-sensitive dyes ANS, Bis-ANS and Nile Red. IgG formulations with polysorbate
Fluid shear stress increases membrane fluidity in endothelial cells: a study with DCVJ fluorescence.
American journal of physiology. Heart and circulatory physiology, 278(4), H1401-H1406 (2000-04-06)
Fluid shear stress (FSS) has been shown to be an ubiquitous stimulator of mammalian cell metabolism. Although many of the intracellular signal transduction pathways have been characterized, the primary mechanoreceptor for FSS remains unknown. One hypothesis is that the cytoplasmic
Indian journal of biochemistry & biophysics, 32(6), 442-446 (1995-12-01)
Di(cyano vinyl)julolidine (DCVJ) is a fluorescent probe which has been used to monitor the local mobility of its binding sites on proteins. It shows a concentration dependence of its emission spectrum in water. At higher DCVJ concentrations, a longer wavelength
Protein science : a publication of the Protein Society, 5(10), 2029-2036 (1996-10-01)
9-(Dicyanovinyl) julolidine (DCVJ) is a fluorescent probe, which binds to a unique site on the tubulin dimer and exhibits different properties that are dependent upon its oligomeric state (Kung & Reed, 1989). DCVJ binds to tubulin, the tubulin-colchicine complex, and
Journal of biological engineering, 11, 24-24 (2017-08-09)
The molecular rotor 9-(2-Carboxy-2-cyanovinyl)julolidine (CCVJ) is presumed to have a sensitivity towards velocity or shear which is supposed to result in a change in fluorescence quantum yield. Furthermore, a previously reported photoisomeric behavior may contribute to the measured fluorescence intensity
我们的科学家团队拥有各种研究领域经验,包括生命科学、材料科学、化学合成、色谱、分析及许多其他领域.
联系技术服务部门