C3669

Liquid chromatography columns

Luer Lock, Non-jacketed, bed volume 4 mL, I.D. × L 0.7 cm × 10 cm

Zaloguj się, aby wyświetlić ceny organizacyjne i kontraktowe.

Wybierz wielkość

10 EA

1072,50 zł

1072,50 zł

Cena katalogowa1430,00 złZaoszczędź 25%

Skontaktuj się z Obsługą Klienta, aby uzyskać informacje na temat dostępności

Zamów zamówienie zbiorcze

Informacje o tej pozycji

UNSPSC Code:
41115711
NACRES:
SB.52
eCl@ss:
32060201

Przejdź do

Pomoc techniczna
Potrzebujesz pomocy? Nasz zespół doświadczonych naukowców chętnie Ci pomoże.
Pozwól nam pomóc

Nazwa produktu

Liquid chromatography columns, Luer Lock, Non-jacketed, bed volume 4 mL, I.D. × L 0.7 cm × 10 cm

technique(s)

LPLC: suitable

I.D. × L

0.7 cm × 10 cm

bed volume

4 mL

suitability

suitable for chromatography

Szukasz podobnych produktów? Odwiedź Przewodnik dotyczący porównywania produktów

General description

All of the columns listed below are constructed of borosilicate glass and are rated at a maximum pressure of 15psi (1 bar). Five configurations are available:
A - Luer-Lock, Non Jacketed: Fixed polypropylene end caps, polyethylene bed supports, Luer-Lock inlet and outlet fittings.
B - Luer-Lock, Jacketed: Same as A (above), with a borosilicate glass jacket surrounding the column body for temperature control.
C - Open-ended: Fixed polypropylene ends (outside of tube only), without jacket or end fittings. Requires 2 flow adapters.
D - PTFE, non-jacketed: Threaded ends, removable PTFE fittings with shielded O-ring seals, 20 μm polyethylene bed supports, and 1/4-28 threaded tubing connections. Solvents contact only PTFE and borosilicate glass.
E - PTFE, jacketed: Same as D (above), with an acrylic jacket surrounding the column body for temperature control.
Ta strona może zawierać tekst przetłumaczony maszynowo.

Wybierz jedną z najnowszych wersji:

Certyfikaty analizy (CoA)

Lot/Batch Number

It looks like we've run into a problem, but you can still download Certificates of Analysis from our Dokumenty section.

Proszę o kontakt, jeśli potrzebna jest pomoc Obsługa Klienta

Masz już ten produkt?

Dokumenty związane z niedawno zakupionymi produktami zostały zamieszczone w Bibliotece dokumentów.

Odwiedź Bibliotekę dokumentów

K Kamino et al.
Science advances, 6(46) (2020-11-15)
In the face of uncertainty, cell populations tend to diversify to enhance survival and growth. Previous studies established that cells can optimize such bet hedging upon environmental change by modulating gene expression to adapt both the average and diversity of
Peter Morris et al.
Journal of bacteriology, 190(6), 2172-2182 (2008-01-08)
A characteristic feature of bacteriophage genomes is that they are architecturally mosaic, with each individual genome representing a unique assemblage of individual exchangeable modules. Plausible mechanisms for generating mosaicism include homologous recombination at shared boundary sequences of module junctions, illegitimate

Questions

1–3 of 3 Questions  
  1. Does this product come with a stop-cock attachment or does that need to be ordered separately? Can you supply product code if needed.

    1 answer
    1. This column does not come fitted with a stopcock attachment, but any stopcock with a Luer Lock fitting can be used. From the same product line, product S7396 is a compatible two-way stopcock, and product S7521 is a compatible three-way stopcock.

      Helpful?

  2. Can the top of this column be unscrewed for packing purposes? Also, do you have a detailed image of this column?

    1 answer
    1. The column has fixed polypropylene end caps, polyethylene bed supports, and Luer-Lock inlet and outlet fittings. The column outlet and reservoir top are permanently attached, while the reservoir cap is threaded. For the 0.7 cm i.d., there is no flow adapter, and a funnel can be used to pack the column after removing the threaded reservoir cap.

      Helpful?

  3. Questo tipo di colonna con codice C-3669 è compatibile con solventi organici come esano, diclorometano o acetato di etile?

    1 answer
    1. This column has not been tested with these solvents. It will be damaged by dichloromethane and ethyl acetate. Hexane may cause swelling and leakage.

      Helpful?

Reviews

No rating value

Active Filters

Nasz zespół naukowców ma doświadczenie we wszystkich obszarach badań, w tym w naukach przyrodniczych, materiałoznawstwie, syntezie chemicznej, chromatografii, analityce i wielu innych dziedzinach.

Skontaktuj się z zespołem ds. pomocy technicznej