material
PTFE membrane, polypropylene , polypropylene housing
sterility
irradiated, non-sterile
Quality Level
product line
Aervent®
feature
hydrophobic
manufacturer/tradename
Aervent®
parameter
2.1 bar max. differential pressure at 25 °C, 4.1 bar max. inlet pressure (60 psi) at 25 °C
technique(s)
gas filtration: suitable
L
7.2 cm (2.84 in.)
W
2.4 in.
diam.
6.2 cm (2.4 in.)
filtration area
19.6 cm2
impurities
≤0.5 EU/mL (LAL test, Aqueous extraction)
gravimetric extractables
≤1.0 mg
matrix
Aervent®
pore size
0.2 μm pore size
bubble point
≥1100 mbar (16 psig), nitrogen with 60/40% IPA/water at 23 °C
fitting
inlet/outlet hose for 6.5-9.5 mm I.D. silicone tubing
shipped in
ambient
1 of 4
Ta pozycja | |||
|---|---|---|---|
| pore size 0.2 μm pore size | pore size 0.2 μm pore size | pore size 0.2 μm pore size | pore size 0.2 μm pore size |
| filtration area 19.6 cm2 | filtration area 19.6 cm2 | filtration area 19.6 cm2 | filtration area 19.6 cm2 |
| technique(s) gas filtration: suitable | technique(s) gas filtration: suitable | technique(s) gas filtration: suitable | technique(s) gas filtration: suitable |
| product line Aervent® | product line Aervent® | product line Aervent® | product line Aervent® |
| matrix Aervent® | matrix Aervent® | matrix Aervent® | matrix Aervent® |
| sterility irradiated, non-sterile | sterility non-sterile | sterility non-sterile | sterility non-sterile |
General description
Application
- Sterile venting of vessels and carboys
- Autoclave vacuum break lines
- Low volume sterile filtration of non-aqueous fluids
- Small fermenter inlet and exhaust gas filtration
Preparation Note
10 autoclave cycles of 30 min @ 130 °C; not in-line steam sterilizable
Analysis Note
Quantitative retention of 107 CFU/cm2Brevundimonas diminuta (ATCC® 19146) per ASTM F838-83 methodology
Other Notes
- Organism Retention: Microorganism
- Mode of Action: Filtration (size exclusion)
- Application: BioProcessing
- Intended Use: Reduction or removal of microorganism/bioburden
- Instructions for Use: Please refer Steam Sterilization & Integrity Testing Procedures guide and first page of Visual Inspection Guide
- Storage Statement: Store in dry location
- Disposal Statement: Dispose of in accordance with applicable federal, state and local regulations.
Legal Information
Certyfikaty analizy (CoA)
Poszukaj Certyfikaty analizy (CoA), wpisując numer partii/serii produktów. Numery serii i partii można znaleźć na etykiecie produktu po słowach „seria” lub „partia”.
Masz już ten produkt?
Dokumenty związane z niedawno zakupionymi produktami zostały zamieszczone w Bibliotece dokumentów.
Active Filters
Nasz zespół naukowców ma doświadczenie we wszystkich obszarach badań, w tym w naukach przyrodniczych, materiałoznawstwie, syntezie chemicznej, chromatografii, analityce i wielu innych dziedzinach.
Skontaktuj się z zespołem ds. pomocy technicznej