Przejdź do zawartości
Merck

MPVL10CA3

Millipak® 100 Capsule Media: Durapore® 0.1 µm

Chemistry: Hydrophilic Polyvinylidene Fluoride (PVDF) Inlet: 9/16 in. Hose Barb Outlet: 9/16 in. Hose Barb

Synonim(y):

Gamma Compatible Millipak -100 Filter Unit 0.1 μm 9/16 in. HB/HB, Durapore® 0.1 µm, Millipak® Capsule

Zaloguj się, aby wyświetlić ceny organizacyjne i kontraktowe.

Wybierz wielkość

3 EA

2110,00 zł

2110,00 zł


Przewidywany termin wysyłki16 marca 2026Szczegóły



Informacje o tej pozycji

UNSPSC Code:
23151806

Przejdź do

Pomoc techniczna
Potrzebujesz pomocy? Nasz zespół doświadczonych naukowców chętnie Ci pomoże.
Pozwól nam pomóc

Nazwa produktu

Millipak® 100 Capsule Media: Durapore® 0.1 µm, Chemistry: Hydrophilic Polyvinylidene Fluoride (PVDF) Inlet: 9/16 in. Hose Barb Outlet: 9/16 in. Hose Barb

material

PVDF , PVDF vent cap, polycarbonate , polycarbonate support

Quality Level

sterility

irradiated, non-sterile

product line

Millipak®

feature

gamma compatible, hydrophilic

manufacturer/tradename

Millipak®

parameter

0.35 bar max. differential pressure (5 psid) at 123 °C (Forward), 0.7 bar max. differential pressure (10 psid) at 25 °C (Reverse), 1.7 bar max. differential pressure (25 psid) at 80 °C (Forward), 3.8 L/min flow rate at 2.45 bar (ΔP), 4.1 bar max. differential pressure (60 psid) at 25 °C (Forward), 5.2 bar max. inlet pressure (75 psi) at 25 °C, 50 L process volume

technique(s)

sterile filtration: suitable

L

5.1 in.

W

3.0 in.

diam.

7.6 cm (3.0 in.)

filtration area

500 cm2

inlet connection diam.

9/16 in.

outlet connection diam.

9/16 in.

impurities

≤0.5 EU/mL bacterial endotoxins (LAL test, Aqueous extraction), <0.5 EU/mL USP bacterial endotoxins (LAL test, sample aqueous extraction)

gravimetric extractables

≤2.5 mg/device

matrix

Durapore®

sterilization compatibility

gamma compatible

pore size

0.1 μm

bubble point

≥4830 mbar (70 psig), air with water at 23 °C

fitting

inlet hose barb, outlet hose barb, (14 mm (9/16 in.) Hose Barb Inlet and Outlet)

Szukasz podobnych produktów? Odwiedź Przewodnik dotyczący porównywania produktów

Porównaj podobne pozycje

Wyświetl pełne porównanie

Pokaż różnice

1 of 4

Ta pozycja
MPGL10CA3MPHL10CA3MPVL10CF3
pore size

0.1 μm

pore size

0.22 μm

pore size

0.45 μm

pore size

0.1 μm

product line

Millipak®

product line

Millipak®

product line

Millipak®

product line

Millipak®

filtration area

500 cm2

filtration area

500 cm2

filtration area

500 cm2

filtration area

500 cm2

technique(s)

sterile filtration: suitable

technique(s)

sterile filtration: suitable

technique(s)

bioburden reduction: suitable

technique(s)

sterile filtration: suitable

sterility

irradiated, non-sterile

sterility

irradiated, non-sterile

sterility

irradiated, non-sterile

sterility

irradiated, non-sterile

matrix

Durapore®

matrix

Durapore®

matrix

Durapore®

matrix

Durapore®

General description

Device Configuration: Capsule

Packaging

Double Easy-Open bag

Preparation Note

Sterilization Method
3 autoclave cycles of 90 min @ 123°C; not in-line steam sterilizable
This product was manufactured with a Durapore® membrane which meets the criteria for a "non-fiber releasing" filter as defined in 21 CFR 210.3 (b) (6).

Analysis Note

Bacterial Retention
Samples were quantitatively retentive of a minimum Brevundimonas diminuta challenge concentration of 1 x 10⁷ CFU/cm² using ASTM® F838 methodology.
Gravimetric Extractables: after 24 hours in water at controlled room temperature
Will meet the USP Oxidizable Substances Test requirements after a water flush of ≥200 mL

Other Notes

Directions for Use

  • Organism Retention: Microorganism
  • Mode of Action: Filtration (size exclusion)
  • Application: BioProcessing
  • Intended Use: Reduction or removal of microorganism/bioburden
  • Instructions for Use: Please refer Wetting Instructions for Filter Units with Durapore® Membrane user guide
  • Storage Statement: Store in dry location
  • Disposal Statement: Dispose of in accordance with applicable federal, state and local regulations.

These products are manufactured in a facility which adheres to FDA Good Manufacturing Practices.

Legal Information

ASTM is a registered trademark of American Society for Testing and Materials
Durapore is a registered trademark of Merck KGaA, Darmstadt, Germany
MILLIPAK is a registered trademark of Merck KGaA, Darmstadt, Germany
Ta strona może zawierać tekst przetłumaczony maszynowo.

Certyfikaty analizy (CoA)

Poszukaj Certyfikaty analizy (CoA), wpisując numer partii/serii produktów. Numery serii i partii można znaleźć na etykiecie produktu po słowach „seria” lub „partia”.

Masz już ten produkt?

Dokumenty związane z niedawno zakupionymi produktami zostały zamieszczone w Bibliotece dokumentów.

Odwiedź Bibliotekę dokumentów

Questions

Reviews

No rating value

Active Filters

Nasz zespół naukowców ma doświadczenie we wszystkich obszarach badań, w tym w naukach przyrodniczych, materiałoznawstwie, syntezie chemicznej, chromatografii, analityce i wielu innych dziedzinach.

Skontaktuj się z zespołem ds. pomocy technicznej