Saltar al contenido
Merck

440752

Sigma-Aldrich

Policaprolactona

greener alternative

average Mw ~14,000, average Mn ~10,000 by GPC

Sinónimos:

Homopolímero de 2-oxepanona, Polímero de 6-caprolactona

Iniciar sesiónpara Ver la Fijación de precios por contrato y de la organización


About This Item

Fórmula lineal:
(C6H10O2)n
Código UNSPSC:
12162002
NACRES:
NA.23
En este momento no podemos mostrarle ni los precios ni la disponibilidad

Formulario

flakes or chunk(s)

mol peso

average Mn ~10,000 by GPC
average Mw ~14,000

características de los productos alternativos más sostenibles

Design for Energy Efficiency
Use of Renewable Feedstocks
Learn more about the Principles of Green Chemistry.

sustainability

Greener Alternative Product

viscosidad

400-1000 mPa.s, 50 wt. % in xylene

mp

60 °C (lit.)

temperatura de transición

Tg −60 °C

densidad

1.146 g/mL at 25 °C

categoría alternativa más sostenible

¿Está buscando productos similares? Visita Guía de comparación de productos

Descripción general

Polycaprolactone is a α,ω-dihydroxy functional polymer.
We are committed to bringing you Greener Alternative Products, which belongs to one of the four categories of greener alternatives. This is an enabling product that belongs to a family of high-performance bio-based polymers that are essential for developing efficient, low-cost, and environmentally friendly renewable energy solutions. Click here for more information.

Aplicación

Polycaprolactone may find use as an extrusion aid, die lubricant, mold release, pigment and filler dispersion aid and polyester segments in urethanes and block polyesters.

Características y beneficios

Polímero biodegradable
No tóxico, biodegradable en el suelo, amplía miscibilidad, compatibilidad química con muchos polímeros y buena adhesión a un amplio espectro de sustratos.

Forma física

α,ω-dihydroxy functional polymer.

Código de clase de almacenamiento

11 - Combustible Solids

Clase de riesgo para el agua (WGK)

WGK 3

Punto de inflamabilidad (°F)

>230.0 °F

Punto de inflamabilidad (°C)

> 110 °C

Equipo de protección personal

Eyeshields, Gloves, type N95 (US)


Elija entre una de las versiones más recientes:

Certificados de análisis (COA)

Lot/Batch Number

¿No ve la versión correcta?

Si necesita una versión concreta, puede buscar un certificado específico por el número de lote.

¿Ya tiene este producto?

Encuentre la documentación para los productos que ha comprado recientemente en la Biblioteca de documentos.

Visite la Librería de documentos

Los clientes también vieron

Slide 1 of 1

1 of 1

Kyungjin Park et al.
Scientific reports, 7(1), 13359-13359 (2017-10-19)
Optical resolution photoacoustic microscopy (OR-PAM) is a non-invasive, label-free method of in vivo imaging with microscopic resolution and high optical contrast. Based on intrinsic contrasts, OR-PAM has expanded to include in vivo vessel imaging, flow cytometry, physiological parameter analysis, and
Jixin Xue et al.
Biomaterials, 34(11), 2624-2631 (2013-01-29)
Tissue engineering approach continuously requires for emerging strategies to improve the efficacy in repairing and regeneration of tissue defects. Previously, we developed a sandwich model strategy for cartilage engineering, using the combination of acellular cartilage sheets (ACSs) and chondrocytes. However
P R Sreerekha et al.
Journal of biomedical nanotechnology, 9(5), 790-800 (2013-06-28)
Fabricating scaffolds mimicking the native extracellular matrix (ECM) in both structure and function is a key challenge in the field of tissue engineering. Previously we have demonstrated a novel electrospinnig method for the fabrication of fibrin nanofibers using Poly(vinyl alcohol)
Kalaipriya Madhaiyan et al.
International journal of pharmaceutics, 444(1-2), 70-76 (2013-02-02)
Biocompatible PCL polymer nanofiber mediated sustained release of hydrophilic drug and applicability as transdermal delivery system is attempted. This new attempt to investigate water soluble vitamin delivery with hydrophobic polymer nanofiber sustained the release of the vitamin and the method
André O'Reilly Beringhs et al.
AAPS PharmSciTech, 22(3), 90-90 (2021-03-06)
Contrast-enhanced X-ray computed tomography plays an important role in cancer imaging and disease progression monitoring. Imaging using radiopaque nanoparticle platforms can provide insights on the likelihood of nanoparticle accumulation and can enable image-guided therapies. Perfluorooctyl bromide (PFOB)-loaded nanocapsules designed for

Artículos

In the past two decades, tissue engineering and regenerative medicine have become important interdisciplinary fields that span biology, chemistry, engineering, and medicine.

Innovations in polymer technology have had a significant impact on the advancement of novel drug delivery systems.

Questions

1–5 of 5 Questions  
  1. What are the end groups of this PCL?

    1 answer
    1. This material is considered a diol and contains a hydroxyl group at each end of the polymer chain.

      Helpful?

  2. How is shipping temperature determined? And how is it related to the product storage temperature?

    1 answer
    1. Products may be shipped at a different temperature than the recommended long-term storage temperature. If the product quality is sensitive to short-term exposure to conditions other than the recommended long-term storage, it will be shipped on wet or dry-ice. If the product quality is NOT affected by short-term exposure to conditions other than the recommended long-term storage, it will be shipped at ambient temperature. As shipping routes are configured for minimum transit times, shipping at ambient temperature helps control shipping costs for our customers. For more information, please refer to the Storage and Transport Conditions document: https://www.sigmaaldrich.com/deepweb/assets/sigmaaldrich/marketing/global/documents/316/622/storage-transport-conditions-mk.pdf

      Helpful?

  3. How can I determine the shelf life / expiration / retest date of this product?

    1 answer
    1. If this product has an expiration or retest date, it will be shown on the Certificate of Analysis (COA, CofA). If there is no retest or expiration date listed on the product's COA, we do not have suitable stability data to determine a shelf life. For these products, the only date on the COA will be the release date; a retest, expiration, or use-by-date will not be displayed.
      For all products, we recommend handling per defined conditions as printed in our product literature and website product descriptions. We recommend that products should be routinely inspected by customers to ensure they perform as expected.
      For products without retest or expiration dates, our standard warranty of 1 year from the date of shipment is applicable.
      For more information, please refer to the Product Dating Information document: https://www.sigmaaldrich.com/deepweb/assets/sigmaaldrich/marketing/global/documents/449/386/product-dating-information-mk.pdf

      Helpful?

  4. What are the associated GHS hazards statements for PCL?

    1 answer
    1. As mentioned in Section 2 of the Safety Data Sheet, there are no GHS Label elements because this product is not classified as a hazardous substance or mixture.

      Helpful?

  5. What is the storage specifications for this chemical?

    1 answer
    1. This product may be stored at room temperature. For products with no specified storage temperature given on the label or product page, ambient storage may be assumed. Products that require controlled temperature storage, such as refrigeration or freezer conditions, storage temperatures are published on the product label, Certificate of Analysis, and the Safety Data Sheet (SDS).

      Helpful?

Reviews

No rating value

Active Filters

Nuestro equipo de científicos tiene experiencia en todas las áreas de investigación: Ciencias de la vida, Ciencia de los materiales, Síntesis química, Cromatografía, Analítica y muchas otras.

Póngase en contacto con el Servicio técnico