NanoFabTx microfluidic - nano

device kit for synthesis of 100-200 nm nanoparticles and liposomes

Sinónimos:

Liposomes, Microfluidic kit, NanoFabTx device kit, Nanoformulation, Nanoparticle

Iniciar sesiónpara Ver la Fijación de precios por contrato y de la organización


About This Item

Código UNSPSC:
12162002
Código UNSPSC:
41121811
NACRES:
NA.23
En este momento no podemos mostrarle ni los precios ni la disponibilidad

descripción

Microfludic device kit for synthesizing nanparticles

Kit components :

  • Microfluidic chip x 1
  • Tubings and accessories

Nivel de calidad

aplicaciones

advanced drug delivery

Descripción general

NanoFabTx Microfluidic - nano device kit is a set of plug-and-play, easy-to-use microfluidic components that are compatible with Dolomite microfluidic systems and standard syringe pumps (not included). The device kit can be combined with our special nanoformulation kits (please visit www.sigmaaldrich.com/nanofabtx) to form nanoparticles or liposomes 100 to 200 nm in size. The device kit includes a comprehensive protocol, pre-assembled microfluidic chip manifold, tubing, and required accessories.

Aplicación

NanoFabTx Microfluidic - nano device kit is designed to work with NanoFabTx - nano reagent kits (including 909637, 918075, and 907766) to synthesize drug-encapsulating liposome nanoparticles (LNP) and drug-encapsulating polymeric nanoparticles for targeted drug delivery research. Our device kit simplifies LNP formulation and polymeric nanoformulation by leveraging microfluidic technologies to achieve narrow size dispersity and high batch-to-batch consistency. The microfluidic chip manifold is chemically robust and compatible with a variety of solvents and therapeutics relevant in nanomedicine. The microfluidic chip geometries and controllable flow enable the user to achieve targetable particle diameters with homogenous shape and structure from 100 to 200 nm in size. By enabling users to easily fine-tune the synthetic parameters, our microfluidic-based tool allows scalable synthesis of drug-encapsulating nanocarriers for researchers in the field of precision medicine, drug discovery, and nanoparticle cancer treatment.

Características y beneficios

  • Step-by-step microfluidic-based protocols developed and tested by our formulation scientists
  • Optimization of drug encapsulation and loading efficiency in nanoparticles and liposomes
  • Selection of optimal nanoparticle and liposome size of any size between 100-200 nm
  • Small reaction volumes to reduce waste of expensive reagents and therapeutics

Información legal

NANOFABTX is a trademark of Sigma-Aldrich Co. LLC

Elija entre una de las versiones más recientes:

Certificados de análisis (COA)

Lot/Batch Number

It looks like we've run into a problem, but you can still download Certificates of Analysis from our Documentos section.

Si necesita más asistencia, póngase en contacto con Atención al cliente

¿Ya tiene este producto?

Encuentre la documentación para los productos que ha comprado recientemente en la Biblioteca de documentos.

Visite la Librería de documentos

Andrew Gdowski et al.
Journal of nanobiotechnology, 16(1), 12-12 (2018-02-13)
The process of optimization and fabrication of nanoparticle synthesis for preclinical studies can be challenging and time consuming. Traditional small scale laboratory synthesis techniques suffer from batch to batch variability. Additionally, the parameters used in the original formulation must be
Samar Damiati et al.
Genes, 9(2) (2018-02-22)
Microfluidic devices present unique advantages for the development of efficient drug carrier particles, cell-free protein synthesis systems, and rapid techniques for direct drug screening. Compared to bulk methods, by efficiently controlling the geometries of the fabricated chip and the flow
Xuanyu Li et al.
Advanced drug delivery reviews, 128, 101-114 (2017-12-27)
Microfluidic chips allow the rapid production of a library of nanoparticles (NPs) with distinct properties by changing the precursors and the flow rates, significantly decreasing the time for screening optimal formulation as carriers for drug delivery compared to conventional methods.

Artículos

NanoFabTx™ platform accelerates drug development with ready-to-use formulations and microfluidic devices for particle synthesis.

NanoFabTx™ platform accelerates drug development with ready-to-use formulations and microfluidic devices for particle synthesis.

NanoFabTx™ platform accelerates drug development with ready-to-use formulations and microfluidic devices for particle synthesis.

NanoFabTx™ platform accelerates drug development with ready-to-use formulations and microfluidic devices for particle synthesis.

Ver todo

Questions

1–4 of 4 Questions  
  1. How is shipping temperature determined? And how is it related to the product storage temperature?

    1 answer
    1. Products may be shipped at a different temperature than the recommended long-term storage temperature. If the product quality is sensitive to short-term exposure to conditions other than the recommended long-term storage, it will be shipped on wet or dry-ice. If the product quality is NOT affected by short-term exposure to conditions other than the recommended long-term storage, it will be shipped at ambient temperature. As shipping routes are configured for minimum transit times, shipping at ambient temperature helps control shipping costs for our customers. For more information, please refer to the Storage and Transport Conditions document: https://www.sigmaaldrich.com/deepweb/assets/sigmaaldrich/marketing/global/documents/316/622/storage-transport-conditions-mk.pdf

      Helpful?

  2. How can I determine the shelf life / expiration / retest date of this product?

    1 answer
    1. If this product has an expiration or retest date, it will be shown on the Certificate of Analysis (COA, CofA). If there is no retest or expiration date listed on the product's COA, we do not have suitable stability data to determine a shelf life. For these products, the only date on the COA will be the release date; a retest, expiration, or use-by-date will not be displayed.
      For all products, we recommend handling per defined conditions as printed in our product literature and website product descriptions. We recommend that products should be routinely inspected by customers to ensure they perform as expected.
      For products without retest or expiration dates, our standard warranty of 1 year from the date of shipment is applicable.
      For more information, please refer to the Product Dating Information document: https://www.sigmaaldrich.com/deepweb/assets/sigmaaldrich/marketing/global/documents/449/386/product-dating-information-mk.pdf

      Helpful?

  3. Me podrían indicar si los chips son de un solo uso o reciclables? Cuántos chips entran en el kit?

    1 answer
    1. This product includes 1 chip and the additional tubing, valves, and accessories required for use. The kit components, including the chip, are reusable. However, proper cleaning is required. Please see the link below to review the product usage instructions, including the cleaning protocol:
      https://www.sigmaaldrich.com/deepweb/assets/sigmaaldrich/product/documents/105/115/911593pis-ms.pdf

      Helpful?

  4. Can more information be provided on the material of construction for NanoFabTx microfluidic chip product 911593? Additionally, is this product compatible with ethyl acetate?

    1 answer
    1. Regarding fluidic compatibility, the most effective approach to address this question is for a review of the fluidic pathway involved, after which compatibility can be verified. The components are as follows:
      1.Tubing: PTFE/FEP – Resistant (A)
      2.Chip: B270 Crown Glass – Resistant (A)
      3.Linear Connector: PEEK – Resistant (A)
      4.Linear Connector Seal: FFKM – Resistant (A)
      5.Linear Connector Screws: Stainless Steel (316) - Resistant (B)
      6.H-Interface: Aluminum - Resistant (A)
      In general, the flow path demonstrates excellent resistance to ethyl acetate. It is advisable to flush the flow path with DI Water/IPA (filtered) before introducing a target solvent to ensure that the fluidic pathway is properly sealed and not leaking prior to use. Additionally, once the process is complete, flushing the solvent out of the system is recommended to ensure cleanliness and dryness.

      Helpful?

Reviews

No rating value

Active Filters

Nuestro equipo de científicos tiene experiencia en todas las áreas de investigación: Ciencias de la vida, Ciencia de los materiales, Síntesis química, Cromatografía, Analítica y muchas otras.

Póngase en contacto con el Servicio técnico