培养基过滤
上游生物负荷控制主要着眼于防止微生物进入细胞培养过程。常规进行无菌过滤可以保护生物反应器和上游过程免遭污染。
选择合适的过滤器进行细胞培养基过滤
我们可提供多种培养基过滤选项,保证每个步骤的无菌性和高性能。过滤器的选择需要以风险分析作为指导,从而识别所需的生物负荷控制水平、细胞培养基处理的效率(通量)以及可用的过滤器形式。在最终确定过滤器选择之前,应确认细胞培养过程的可接受性能标准。
Millipore Express® SHR(无菌、高保留率) 该过滤器包含一层0.1 µm的聚醚砜(PES)膜,并可选配一体式的0.5 µm PES膜预过滤器,以对高通量膜进行保护,防止过早发生堵塞。这些过滤器通常可去除≥7.0对数级的支原体并达到无菌级性能。
Millipore Express® SHC(无菌、大容量) 过滤器包含两层(0.5/0.2 µm)PES膜,可提供出色的通量和堵塞流的能力。这些过滤器具有无菌级的性能。
Durapore® 0.1 µm和0.22 µm 过滤器包含一层聚偏二氟乙烯(PVDF)膜,并可提供高流速和通量。这些过滤器具有无菌级的性能。
相关资源
- mAbsizer™ Calculator
mAb Expression, Purification, and Formulation
- Application Note: Cell Culture Media Filtration – Filter Selection and Sizing
This document discusses the trend in bioprocessing to enhance productivity upstream through improved cell culture media processing, highlighting the challenges posed by concentrated and complex media that can lead to premature fouling of membrane filters. It emphasizes the importance of selecting the right membrane filter, particularly addressing microbial retention, and explores the trade-offs between different filter options such as traditional sterilizing-grade filters and mycoplasma-retentive filters in minimizing bioreactor contamination risk.
- Application Note: Cell Culture Media Filtration - Evaluating Cell Culture Performance
This document addresses the challenge of efficiently processing highly concentrated and complex cell culture media, emphasizing the benefits of membrane filtration in reducing the risk of bioreactor contamination. It discusses key considerations in selecting membrane filters based on microbial retention, compatibility, and capacity for specific media.
- Technical Note: Demonstrating Millipore Express® SHR Mycoplasma Clearance Capability at Pilot and Production Scale over an Extended Filtration
Two studies were conducted to assess the mycoplasma retentive properties of Millipore Express® SHR with Prefilter filters using Acholeplasma laidlawii ATCC® 23206™, simulating typical processing parameters and operating pressures. The studies demonstrated that the filters, in both production scale and pilot scale configurations, were fully retentive when challenged with A. laidlawii at low organism challenge levels over extended filtration times.
- Application Note: Integrity Test Troubleshooting – Beyond Rewet and Retest
Integrity testing is crucial for sterilizing grade filters in biopharmaceutical processing, offering a fast, definitive, non-destructive way to ensure filter retention performance. However, while non-integral filters are unlikely to pass the integrity test, there are numerous ways an integral filter can fail, leading to retests and potential productivity and product loss.
- Technical Brief: Extended Bacterial Retention Testing of Millipore Express® 0.2 μm Filters in a Continuous Flow System
The technical brief describes the microbial retention performance of sterilizing-grade Millipore Express® SHF filters under continuous flow operations for up to 16 hours, addressing the limitations of traditional testing methods and providing a more comprehensive understanding of filter performance in real-world biomanufacturing processes.
- Technical Note: Mycoplasma clearance by Millipore Express® SHR filters at pilot and production scales
The Millipore Express® SHR filters, equipped with a 0.1 µm polyethersulfone (PES) sterilizing membrane, offer enhanced microbial risk reduction, particularly targeting mycoplasma contaminants in cell culture media. Retention studies demonstrated that both pilot and production-scale filters consistently provided the expected level of mycoplasma retention over extended filtration times, affirming their performance under continuous flow processing conditions.
- PDF: Millpore Express® Family Guide
Millipore Express® filters, featuring hydrophilic polyethersulfone (PES) membranes, are trusted for their sterilizing-grade filtration, high flux, and capacity, with broad chemical compatibility and ease of use for wetting and integrity testing. These filters are versatile, suitable for various biomanufacturing operations, including filtration of cell culture media, monoclonal antibodies (mAbs), vaccines, plasma, viral vector, and parenteral production at different scales.
- Durapore® Family Guide
Durapore® polyvinylidene fluoride (PVDF) membranes are a trusted choice for various bioprocessing operations, including liquid sterile filtration, sterile tank and gas venting, and final sterilizing filtration, offering low protein binding, broad chemical compatibility, and low extractables. These membranes are versatile, suitable for applications such as filtration of cell culture media, monoclonal antibodies (mAbs), vaccines, plasma, viral vector intermediates, and ophthalmics, with the additional assurance of 100% integrity testing for all Durapore® sterilizing filters during manufacturing.