跳转至内容
Merck

84818

Supelco

癸二酸二(2-乙基己基)酯

Selectophore, ≥97.0%

别名:

二(2-乙基己基)癸二酸酯, 癸二酸二(2-乙基己基)酯, 癸二酸二辛酯

登录查看公司和协议定价


About This Item

线性分子式:
[-(CH2)4CO2CH2CH(C2H5)(CH2)3CH3]2
CAS号:
分子量:
426.67
Beilstein:
1806504
EC號碼:
MDL號碼:
分類程式碼代碼:
26111700
PubChem物質ID:
NACRES:
NB.61

等級

for ion-selective electrodes

品質等級

產品線

Selectophore

化驗

≥97.0% (GC)
≥97.0%

形狀

liquid

折射率

n20/D 1.450 (lit.)

bp

212 °C/1 mmHg (lit.)

密度

0.914 g/mL at 25 °C (lit.)

SMILES 字串

CCCCC(CC)COC(=O)CCCCCCCCC(=O)OCC(CC)CCCC

InChI

1S/C26H50O4/c1-5-9-17-23(7-3)21-29-25(27)19-15-13-11-12-14-16-20-26(28)30-22-24(8-4)18-10-6-2/h23-24H,5-22H2,1-4H3

InChI 密鑰

VJHINFRRDQUWOJ-UHFFFAOYSA-N

正在寻找类似产品? 访问 产品对比指南

一般說明

二(2-乙基己基)癸二酸酯(BEHS)是一种广泛用于制备离子选择性电极的增塑剂。
请见我们的 传感器应用门户 网站,了解更多信息。

應用

BEHS用于制备PVC膜阴离子表面活性剂选择性电极。

法律資訊

Selectophore is a trademark of Merck KGaA, Darmstadt, Germany

儲存類別代碼

10 - Combustible liquids

水污染物質分類(WGK)

awg

個人防護裝備

Eyeshields, Gloves


Choose from one of the most recent versions:

分析证书(COA)

Lot/Batch Number

Don't see the Right Version?

If you require a particular version, you can look up a specific certificate by the Lot or Batch number.

已有该产品?

在文件库中查找您最近购买产品的文档。

访问文档库

Mercury (II) ion-selective electrodes based on p-tert-butyl calix [4] crowns with imine units.
Mahajan, Rakesh Kumar, et al.
Analytical Sciences, 20.5, 811-814 (2004)
A new ion-selective electrode for anionic surfactants.
Segui, Ma Jesus, et al.
Talanta, 71.1, 333-338 (2007)
P J Anderson et al.
The American review of respiratory disease, 144(3 Pt 1), 649-654 (1991-09-01)
How variable is the deposition of inhaled methacholine (MCH) in the respiratory tract during a challenge test? Does this variability contribute to the variability of airway responsiveness? To examine these questions we estimated the deposition of polydisperse MCH droplets by
H Schulz et al.
The European respiratory journal, 8(4), 566-573 (1995-04-01)
The contribution of aerosol techniques, the estimation of aerosol bolus dispersion and effective airway dimensions, to the clinical diagnosis of paediatric asthma was studied. In 47 children, aged 11 +/- 2 yrs, with mild asthma (forced expiratory volume in one
F J Wilson et al.
Journal of applied physiology (Bethesda, Md. : 1985), 58(1), 223-229 (1985-01-01)
Theoretical models of particle deposition in the respiratory tract predict high fractional deposition for particles of less than 0.1 micron, but there are few confirming experimental data for those predictions. We have measured the deposition fraction of a nonhygroscopic aerosol

我们的科学家团队拥有各种研究领域经验,包括生命科学、材料科学、化学合成、色谱、分析及许多其他领域.

联系技术服务部门