跳转至内容
Merck

73732

Supelco

2-硝基苯辛醚

Selectophore, ≥99.0%

别名:

1-硝基-2-辛氧基苯

登录查看公司和协议定价


About This Item

线性分子式:
O2NC6H4O(CH2)7CH3
CAS号:
分子量:
251.32
Beilstein:
2529905
EC號碼:
MDL號碼:
分類程式碼代碼:
26111700
PubChem物質ID:
NACRES:
NB.61

等級

for ion-selective electrodes

品質等級

產品線

Selectophore

化驗

≥99.0% (GC)
≥99.0%

形狀

liquid

折射率

n20/D 1.508 (lit.)
n20/D 1.511

bp

197-198 °C/11 mmHg (lit.)

密度

1.04 g/mL at 25 °C (lit.)

SMILES 字串

CCCCCCCCOc1ccccc1[N+]([O-])=O

InChI

1S/C14H21NO3/c1-2-3-4-5-6-9-12-18-14-11-8-7-10-13(14)15(16)17/h7-8,10-11H,2-6,9,12H2,1H3

InChI 密鑰

CXVOIIMJZFREMM-UHFFFAOYSA-N

正在寻找类似产品? 访问 产品对比指南

一般說明

2-硝基苯基辛基醚(NPOE)通常用于液/液界面中的离子转移。它的水溶解度低、蒸气压低并且毒性低于其他有机溶剂。它是离子溶质的良好溶剂,因为它具有高摩尔体积和中等介电常数。
请访问我们的 传感器应用门户网站,了解更多信息。

應用

NPOE被用作PVC膜阴离子表面活性剂选择性电极的增塑剂。

特點和優勢

可用作三醋酸纤维素膜的增塑剂,使得金属阳离子不可透过但允许阴离子交换。

法律資訊

Selectophore is a trademark of Merck KGaA, Darmstadt, Germany

儲存類別代碼

10 - Combustible liquids

水污染物質分類(WGK)

WGK 3

閃點(°F)

235.4 °F - closed cup

閃點(°C)

113 °C - closed cup

個人防護裝備

Eyeshields, Gloves


历史批次信息供参考:

分析证书(COA)

Lot/Batch Number

没有发现合适的版本?

如果您需要特殊版本,可通过批号或批次号查找具体证书。

已有该产品?

在文件库中查找您最近购买产品的文档。

访问文档库

A new ion-selective electrode for anionic surfactants.
Segui MA
Talanta, 71(1), 333-338 (2007)
Molecular dynamics study of 2-nitrophenyl octyl ether and nitrobenzene.
Jorge, Miguel, et al.
The Journal of Physical Chemistry B, 110.25, 12530-12538 (2006)
Xiaohui Chen et al.
Journal of experimental botany, 69(21), 5279-5291 (2018-08-14)
To develop elite crops with low cadmium (Cd), a fundamental understanding of the mechanism of Cd uptake by crop roots is necessary. Here, a new mechanism for Cd2+ entry into rice root cells was investigated. The results showed that Cd2+
A R Pereira et al.
Analytical and bioanalytical chemistry, 412(15), 3629-3637 (2020-04-03)
Histamine intolerance results from a disequilibrium of accumulated histamine and the capacity for histamine degradation. An impaired histamine degradation based on reduced DAO activity and the resulting histamine excess may cause numerous symptoms mimicking an allergic reaction. For that, the
Jiahong Lei et al.
Analytica chimica acta, 858, 60-65 (2015-01-20)
A flow injection system incorporated with a polycation-sensitive polymeric membrane electrode in the flow cell is proposed for potentiometric determination of heparin. An external current in nano-ampere scale is continuously applied across the polymeric membrane for controlled release of protamine

我们的科学家团队拥有各种研究领域经验,包括生命科学、材料科学、化学合成、色谱、分析及许多其他领域.

联系技术服务部门