Yes, Express Fused-Core™ particles were designed with LC-MS in mind. Even extremely short column lengths exhibit sufficient plate counts to show high resolving power. The flat van Deemter plots permit resolution to be maintained at very high flow rates to maximize sample throughput. All Ascentis stationary phases have been evaluated for MS compatibility during their development, and the Express phases are no exception. You can expect extremely low column bleed and background while maintaining longest possible column lifetime. A bonus of product 53313-U Ascentis® Express Peptide ES C18 HPLC Column for high throughput UHPLC and LC-MS is that they are extremely rugged and highly resistant to plugging, a very common failure mode for competitor columns.
₩1,268,344
출고 가능일2025년 4월 11일세부사항
추천 제품
제품명
Ascentis® Express Peptide ES-C18, 2.7 μm HPLC Column, 2.7 μm particle size, L × I.D. 10 cm × 3 mm
material
stainless steel column
Agency
suitable for USP L1
제품 라인
Ascentis®
특징
endcapped: no
제조업체/상표
Ascentis®
포장
1 ea of
파라미터
≤100 °C temp. range
600 bar max. pressure (9000 psi)
기술
HPLC: suitable
LC/MS: suitable
UHPLC-MS: suitable
UHPLC: suitable
길이 × I.D.
10 cm × 3 mm
표면적
90 m2/g
불순물
<5 ppm metals
Matrix
Fused-Core particle platform
superficially porous particle
기질 활성군
C18 (octadecyl) phase
입자 크기
2.7 μm
공극 크기
160 Å
작동 pH 범위
1-9
분리 기술
reversed phase
유사한 제품을 찾으십니까? 방문 제품 비교 안내
일반 설명
법적 정보
가아드 카트리지
관련 제품
애플리케이션
Storage Class Code
11 - Combustible Solids
WGK
WGK 3
Flash Point (°F)
Not applicable
Flash Point (°C)
Not applicable
가장 최신 버전 중 하나를 선택하세요:
시험 성적서(COA)
문서
Choose Ascentis® Express Peptide ES-C18 U/HPLC Columns based on Fused-Core® technology for fast and efficient separation of high-molecular weight compounds, such as peptides and small proteins. With a 2.7 µm particle size and rigorous testing, these columns offer reliable results and high efficiency.
Chromatograms
application for HPLC-
Can product 53313-U Ascentis® Express Peptide ES C18 HPLC column be used for LC-MS?
1 답변-
도움이 되었습니까?
-
-
Can I use product 53313-U Ascentis® Express Peptide ES C18 HPLC Column on any type of HPLC system?
1 답변-
Product 53313-U Ascentis® Express Peptide ES C18 HPLC Column HPLC columns is capable of use on standard HPLC systems as well as UHPLC systems. This column is packed in high pressure hardware capable of withstanding the pressures used in UHPLC systems.
도움이 되었습니까?
-
-
Do I need special fittings and tubing to connect product 53313-U Ascentis® Express Peptide ES C18 HPLC ColumnExpress columns?
1 답변-
While operating pressures may not exceed the 400 bar (6,000 psi) capability of your traditional instruments, sustained pressures of about 200 bar (3,000 psi) will exceed the recommended pressure for conventional PEEK tubing and fittings at the column inlet. We recommend changing to stainless steel fittings in all high pressure locations and have designed special High Performance HPLC Fittings/Interconnects that will stay tight at pressures of 1,000 bar (15,000 psi) or greater, even when elevated column temperatures are employed.
도움이 되었습니까?
-
-
Are guard columns available for product 53313-U Ascentis® Express Peptide ES C18 HPLC Column?
1 답변-
Yes, we have guard columns available for product 53313-U Ascentis® Express Peptide ES C18 HPLC Column. Product 53500-U is the Ascentis® Express Guard Holder and Product 53537-U Ascentis® Express Peptide ES C18 Guard Cartridge is a package of three guard cartridges, 2.7 μm particle size, L 5mm × I.D. 3.0 mm .
도움이 되었습니까?
-
-
What is the carbon load for product 53313-U Ascentis® Express Peptide ES C18 HPLC Column?
1 답변-
Carbon load which is commonly referred to as %Carbon is misleading and not meaningful for Ascentis Express. Since Fused-Core™ particle is unique in the sense that it has a solid core and porous shell, the %Carbon number can not be compared to traditional porous particles. The carbon coverage for product 53313-U Ascentis® Express Peptide ES C18 HPLC column is 2 micromoles/meter-squared.
도움이 되었습니까?
-
-
Is there anything special I need to do to my HPLC system to use product 53313-U Ascentis® Express Peptide ES C18 HPLC Column?
1 답변-
Nothing special is required to use product 53313-U Ascentis® Express Peptide ES C18 HPLC Column. To obtain the full benefits of Ascentis® Express Column, one should minimize dispersion or instrument bandwidth in the HPLC system (tubing, detector flow cell) as well as confirm the detector response system is set at a fast level. For more information, request Guidelines for Optimizing Performance with Ascentis® Express HPLC Columns (T407102).
도움이 되었습니까?
-
-
What is special about product 53313-U Ascentis® Express Peptide ES C18 HPLC Column?
1 답변-
Product 53313-U Ascentis® Express Peptide ES C18 HPLC Column provides a breakthrough in HPLC performance. Based on Fused-Core particle technology, Ascentis® Express columns provide the benefits of sub-2 μm particles but at much lower backpressure. These benefits include the capability of providing fast HPLC and higher resolution chromatography. The Fused-Core particle consists of a 1.7 μm solid core and a 0.5 μm porous shell. A major benefit of the Fused-Core particle is the small diffusion path (0.5 μm) compared to conventional fully porous particles. The shorter diffusion path reduces axial dispersion of solutes and minimizes peak broadening.
도움이 되었습니까?
-
-
What is the pressure rating for product 53313-U Ascentis® Express Peptide ES C18 HPLC Column?
1 답변-
This product 53313-U Ascentis® Express Peptide ES C18 HPLC Column is stable to operating pressures up to 600 bar (9000 psi)
도움이 되었습니까?
-
-
How can I measure my instrument bandwidth (IBW) and determine what columns can be used with minimal efficiency loss created by too much internal instrument volume?
1 답변-
The Guide to Dispersion Measurement has simple instructions on how to measure IBW and can be found at sigma-aldrich.com/express.
도움이 되었습니까?
-
-
Can I use product 53313-U Ascentis® Express Peptide ES C18 HPLC Column on a UHPLC system?
1 답변-
Yes. product 53313-U Ascentis® Express Peptide ES C18 HPLC columns are packed in a way making them suitable for these ultra high pressure instruments. In fact, product 53313-U Ascentis® Express Peptide ES C18 HPLC Column outperforms sub-2 μm micron columns on many applications since product 53313-U Ascentis® Express Peptide ES C18 HPLC Column provides the benefits of sub-2 μm particles but at much lower back pressure. These benefits include the capability of providing fast HPLC and higher resolution chromatography. The Fused-Core particle consists of a 1.7 μm solid core and a 0.5 μm porous shell. A major benefit of the Fused-Core particle is the small diffusion path (0.5 μm) compared to conventional fully porous particles. The shorter diffusion path reduces axial dispersion of solutes and minimizes peak broadening.