주요 문서

28942-U

Supelco

Carbosieve SIII

stainless steel TD tube, unconditioned

로그인조직 및 계약 가격 보기


About This Item

UNSPSC 코드:
41104008
가격 및 재고 정보를 현재 이용할 수 없음

material

stainless steel TD tube

Agency

EPA TO-2

특징

unconditioned

포장

pkg of 10 ea

O.D. × L

1/4 in. × 3 1/2 in.

Matrix

Carbosieve S-III carbon molecular sieve

응용 분야

environmental
industrial hygiene

호환성

for use with PerkinElmer ATD-50,ATD-400 and TurboMatrix (TMX) Series

유사한 제품을 찾으십니까? 방문 제품 비교 안내

법적 정보


가장 최신 버전 중 하나를 선택하세요:

시험 성적서(COA)

Lot/Batch Number

It looks like we've run into a problem, but you can still download Certificates of Analysis from our 문서 section.

도움이 필요하시면 연락하세요. 고객 지원 부서

이 제품을 이미 가지고 계십니까?

문서 라이브러리에서 최근에 구매한 제품에 대한 문서를 찾아보세요.

문서 라이브러리 방문

Yannick Juillet et al.
The Analyst, 130(6), 977-982 (2005-05-25)
Among the chemicals belonging to the schedules of the Chemical Weapons Convention (CWC), sampling and analysis of highly volatile compounds such as hydrogen cyanide (HCN) require special consideration. The latter is present in numerous old chemical weapons that are stockpiled
Juliane Hollender et al.
Journal of chromatography. A, 962(1-2), 175-181 (2002-08-30)
A simple method using active trapping on adsorbents and thermal desorption followed by GC-MS analysis was developed for the indoor air monitoring of monoterpenes. The study was carried out using a dynamically generated atmosphere consisting of 11 monoterpenes: camphene, camphor
C Y Peng et al.
Journal of environmental monitoring : JEM, 2(4), 313-324 (2001-03-16)
Air sampling, using sorbents, thermal desorption and gas chromatography, is a versatile method for identifying and quantifying trace levels of volatile organic compounds (VOCs). Thermal desorption can provide high sensitivity, appropropriate choices of sorbents and method parameters can accommodate a
John L Martin et al.
Journal of occupational and environmental hygiene, 1(6), 363-370 (2004-07-09)
In an effort to assess the scope of occupational exposures to ethylene, the Olefins Panel of the American Chemistry Council designed and conducted a research project to develop and apply a sampling and analytical method to measure workplace exposure. The
R A Borders et al.
American Industrial Hygiene Association journal, 47(3), 158-163 (1986-03-01)
Thermal desorption is a more sensitive alternative to solvent desorption for the determination of acrylonitrile in air. A dual-bed collection tube (Tenax GC and Carbosieve B) was developed for collecting and concentrating low levels of acrylonitrile. Two thermal desorption techniques