콘텐츠로 건너뛰기
Merck
모든 사진(1)

문서

MSCAL3

Supelco

ProteoMass Protein MALDI-MS Calibration Kit

Protein MALDI MS Calibration Standard

동의어(들):

Protein Mass Spectrometry Calibrators

로그인조직 및 계약 가격 보기


About This Item

UNSPSC 코드:
12161503
NACRES:
NA.24

제품 라인

ProteoMass

품질

Protein MALDI MS Calibration Standard

응용 분야

cleaning products
cosmetics
flavors and fragrances
food and beverages
personal care

저장 온도

15-25°C

애플리케이션

This kit features a convenient selection of pre-qualified standard proteins, matrices, and solvents for calibrating and testing matrix assisted laser desorption ionization (MALDI) mass spectrometers. Configured specifically for applications in the mass range of 5 to 66 kDa, MSCAL3 is ideal for most protein studies. Applications include calibration, tuning, and sensitivity testing of MALDI instruments from all manufacturers.
ProteoMass Protein MALDI-MS Calibration Kit has been used as a mass calibration standard for MALDI-TOF MS (matrix assisted laser desorption ionization-time of flight mass spectrometry) analysis.

법적 정보

6538 is a trademark of American Type Culture Collection
ProteoMass is a trademark of Sigma-Aldrich Co. LLC

키트 구성품 전용

제품 번호
설명

  • Sinapinic acid, Use tested for MALDI-TOF Mass Spec. 8 x 10

키트 구성품 역시 별도로 이용 가능함

제품 번호
설명
SDS

  • I6279ProteoMass Insulin MALDI-MS Standard, vial of 10 nmol, monoisotopic mol wt 5,729.6087 Da 2 x 10SDS

  • C8857ProteoMass Cytochrome c MALDI-MS Standard, vial of 10 nmol, (M+H+) 12,361.96 Da by calculation 2 x 10SDS

  • A8971ProteoMass Apomyoglobin MALDI-MS Standard, vial of 10 nmol, (M+H+) 16,952.27 Da by calculation 2 x 10SDS

  • A9096ProteoMass Aldolase MALDI-MS Standard, vial of 10 nmol, average mol wt 39,211.28 Da by calculation 2 x 10SDS

  • A8471ProteoMass Albumin MALDI-MS Standard, vial of 10 nmol, average mol wt 66,429.09 Da by calculation 2 x 10SDS

  • Acetonitrile 30 mL

관련 제품

제품 번호
설명
가격

픽토그램

FlameExclamation mark

신호어

Danger

유해 및 위험 성명서

Hazard Classifications

Acute Tox. 4 Dermal - Acute Tox. 4 Inhalation - Acute Tox. 4 Oral - Eye Irrit. 2 - Flam. Liq. 2 - Skin Irrit. 2 - STOT SE 3

표적 기관

Respiratory system

Storage Class Code

3 - Flammable liquids

WGK

WGK 3


시험 성적서(COA)

제품의 로트/배치 번호를 입력하여 시험 성적서(COA)을 검색하십시오. 로트 및 배치 번호는 제품 라벨에 있는 ‘로트’ 또는 ‘배치’라는 용어 뒤에서 찾을 수 있습니다.

이 제품을 이미 가지고 계십니까?

문서 라이브러리에서 최근에 구매한 제품에 대한 문서를 찾아보세요.

문서 라이브러리 방문

Marta Martínez-Júlvez et al.
The FEBS journal, 279(23), 4306-4317 (2012-10-09)
The RdxA oxygen-insensitive nitroreductase of the human gastric pathogen Helicobacter pylori is responsible for the susceptibility of this organism to the redox active prodrug metronidazole [2-(2-methyl-5-nitro-1H-imidazol-1-yl)ethanol]. Loss-of-function mutations in rdxA are primarily responsible for resistance to this therapeutic. RdxA exhibits potent
Wipawadee Sianglum et al.
PloS one, 6(2), e16628-e16628 (2011-02-18)
The ethanolic extract from Rhodomyrtus tomentosa leaf exhibited good antibacterial activities against both methicillin-resistant Staphylococcus aureus (MRSA) and S. aureus ATCC 29213. Its minimal inhibitory concentration (MIC) values ranged from 31.25-62.5 µg/ml, and the minimal bactericidal concentration (MBC) was 250
Binding of the N-terminal domain of the lactococcal bacteriophage TP901-1 CI repressor to its target DNA: a crystallography, small angle scattering, and nuclear magnetic resonance study.
Frandsen KH, et al.
Biochemistry, 52, 6892-6904 (2013)
Expression and purification of recombinant apolipoprotein A-I Zaragoza (L144R) and formation of reconstituted HDL particles.
Fiddyment S, et al.
Protein Expression and Purification, 80, 110-116 (2011)
Tyler A Zimmerman et al.
Analytical chemistry, 83(15), 6090-6097 (2011-06-23)
In-source decay (ISD) fragmentation as combined with matrix-assisted laser desorption/ionization (MALDI) mass spectrometry allows protein sequencing directly from mass spectra. Acquisition of MALDI-ISD mass spectra from tissue samples is achieved using an appropriate MALDI matrix, such as 1,5-diaminonaphthalene (DAN). Recent

관련 콘텐츠

Discover our wide variety of products for intact mass analysis of monoclonal antibodies, including size-exclusion columns (SEC), ion exchange columns, reverse-phase columns, HPLC buffers, MALDI matrices and standards, high-purity solvents, reagents, tools for protein sample preparation, and certified reference materials.

단클론 항체의 무손상 질량 분석을 위한 Merck의 다양한 제품에 대해 알아보세요. 크기 배제 컬럼(SEC, size-exclusion column), 이온 교환 컬럼, 역상 컬럼, HPLC 버퍼, MALDI 기질 및 표준 물질, 고순도 용매, 시약, 단백질 검체 준비용 기구, 공인 참조 물질 등이 있습니다.

자사의 과학자팀은 생명 과학, 재료 과학, 화학 합성, 크로마토그래피, 분석 및 기타 많은 영역을 포함한 모든 과학 분야에 경험이 있습니다..

고객지원팀으로 연락바랍니다.