MAK119

Sigma-Aldrich

Acetylcholinesterase Activity Assay Kit

sufficient for 100 colorimetric tests

동의어(들):

ACHE Activity Assay, RBC Cholinesterase Activity Assay

로그인조직 및 계약 가격 보기

크기 선택

1 KIT
₩843,161

₩843,161


예상 입고일2025년 4월 14일세부사항


벌크 견적 요청

크기 선택

보기 변경
1 KIT
₩843,161

About This Item

UNSPSC 코드:
12161503
NACRES:
NA.84

₩843,161


예상 입고일2025년 4월 14일세부사항


벌크 견적 요청

사용

sufficient for 100 colorimetric tests

검출 방법

colorimetric

관련 질환(들)

neurological disorders

저장 온도

room temp

유전자 정보

human ... ACHE(43)
mouse ... ACHE(11423)

일반 설명

Acetylcholinesterases (AChEs) are enzymes that hydrolyze the neurotransmitter acetylcholine (ACh) to acetate and choline. AChE is located at the synaptic cleft and functions to terminate synaptic transmission by catalyzing the breakdown of ACh allowing cholinergic neurons to return to a resting state after activation. It is also found in membranes of red blood cells, motor and sensory fibers, muscles, nerves and central and peripheral tissues. Changes in AChE activity may result from exposure to certain insecticides, which act as cholinesterase inhibitors. Inhibitors of AChE are also used to treat certain conditions such as dementia.[1]

애플리케이션

Acetylcholinesterase activity assay kit has been used to determine the activity of acetylcholinesterase in a rat organophosphate model[2] and in brain tissue homogenates.[3]

특징 및 장점

Compatible with high-throughput handling systems. Can be adapted for use with cuvettes.

적합성

Suitable for the detection of acetylcholinesterase activity in biological samples such as blood, serum, and plasma.

원리

This assay is an optimized version of the Ellman method in which thiocholine, produced by AChE, reacts with 5,5′-dithiobis(2-nitrobenzoic acid) to form an colorimetric (412 nm) product, proportional to the AChE activity present. One unit of AChE is the amount of enzyme that catalyzes the production of 1.0 μmole of thiocholine per minute at room temperature at pH 7.5. This kit has a linear range of 10-600 units/L of AChE activity.

Storage Class Code

10 - Combustible liquids

WGK

WGK 3


가장 최신 버전 중 하나를 선택하세요:

시험 성적서(COA)

Lot/Batch Number

적합한 버전을 찾을 수 없으신가요?

특정 버전이 필요한 경우 로트 번호나 배치 번호로 특정 인증서를 찾을 수 있습니다.

이 제품을 이미 가지고 계십니까?

문서 라이브러리에서 최근에 구매한 제품에 대한 문서를 찾아보세요.

문서 라이브러리 방문

Hemanga Hazarika et al.
Scientific reports, 12(1), 2180-2180 (2022-02-11)
Mosquito-borne infections like dengue, malaria, chikungunya, etc. are a nuisance and can cause profound discomfort to people. Due to the objectional side effects and toxicity associated with synthetic pyrethroids, N,N-diethyl-3-methylbenzamide (DEET), N,N-diethyl phenylacetamide (DEPA), and N,N-di ethyl benzamide (DEBA) based
Abdullah M Alzahrani
Environmental science and pollution research international, 26(16), 16548-16555 (2019-04-14)
Despite the widespread use of the insecticide imidacloprid (IMI), a neonicotinoid, there is an urgent need for documenting information related to its acute toxicity. Therefore, this study aims to explore the markers of IMI acute toxicity in the testes of
Study on social isolation as a risk factor in development of Alzheimer?s disease in rats.
Ali A A, et al.
Brain disorders & therapy., 6(230), 2-2 (2017)
Amrita Mukherjee et al.
Environmental science and pollution research international, 26(23), 23442-23452 (2019-06-15)
The current study demonstrates oxidative damage and associated neurotoxicity following pH stress in two freshwater carp Labeo rohita and Cirrhinus cirrhosus. Carp (n = 6, 3 replicates) were exposed to four different pH (5.5, 6, 7.5, and 8) against control (pH 6.8 ± 0.05) for
P Kumari et al.
Parasitology, 144(10), 1412-1416 (2017-06-07)
Demodex canis infestation in dogs remains one of the main challenges in veterinary dermatology. The exact pathogenesis of canine demodicosis is unknown but an aberration in immune status is considered very significant. No studies have underpinned the nexus between induction

질문

1–9 / 9 질문  
  1. How can I determine the shelf life / expiration / retest date of this product?

    1 답변
    1. If this product has an expiration or retest date, it will be shown on the Certificate of Analysis (COA, CofA). If there is no retest or expiration date listed on the product's COA, we do not have suitable stability data to determine a shelf life. For these products, the only date on the COA will be the release date; a retest, expiration, or use-by-date will not be displayed.
      For all products, we recommend handling per defined conditions as printed in our product literature and website product descriptions. We recommend that products should be routinely inspected by customers to ensure they perform as expected.
      For products without retest or expiration dates, our standard warranty of 1 year from the date of shipment is applicable.
      For more information, please refer to the Product Dating Information document: https://www.sigmaaldrich.com/deepweb/assets/sigmaaldrich/marketing/global/documents/449/386/product-dating-information-mk.pdf

      도움이 되었습니까?

  2. How is shipping temperature determined? And how is it related to the product storage temperature?

    1 답변
    1. Products may be shipped at a different temperature than the recommended long-term storage temperature. If the product quality is sensitive to short-term exposure to conditions other than the recommended long-term storage, it will be shipped on wet or dry-ice. If the product quality is NOT affected by short-term exposure to conditions other than the recommended long-term storage, it will be shipped at ambient temperature. As shipping routes are configured for minimum transit times, shipping at ambient temperature helps control shipping costs for our customers. For more information, please refer to the Storage and Transport Conditions document: https://www.sigmaaldrich.com/deepweb/assets/sigmaaldrich/marketing/global/documents/316/622/storage-transport-conditions-mk.pdf

      도움이 되었습니까?

  3. Can MAK119-1KT acetylcholinesteraseactivity kit used for plant samples also?

    1 답변
    1. There is no information or data on this kit for usage with plant samples. However, there are no indications that it would not work with extracted plant samples with acetylcholinesterase activity within the range of 10 to 600 units per liter.

      도움이 되었습니까?

  4. このキットはAChEに特異的に反応しますか? 血漿中のBuChEには反応しませんか?

    1 답변
    1. This kit will detect acetylcholinesterase and butyrylcholinesterase and will not distinguish between the two.

      도움이 되었습니까?

  5. Is it possible to dilute samples by 40x and extend the incubation time to accommodate those that fall below the linear range? Should we adhere to the 10-minute reaction time, or could we consider a longer incubation period to address issues associated with the yellow color continuing to develop when the plate is left out? This consideration arises from the need for a larger change in OD to accurately measure enzymatic activity, particularly due to issues with running out of the Assay Buffer for diluting samples by 40x.

    1 답변
    1. It is recommended to keep the reaction time at 10 minutes, as the calibrator provided in the kit exhibits the same absorbance as 200 U/L acetylcholinesterase at 10 minutes and does not receive the working reagent. However, to increase the signal of the assay, the customer may increase the sample to working reagent volume. For instance, instead of adding 10 uL of sample to each well, add 20 uL of sample to each well. The plate should still be read at the 2 and 10 minute marks. Additionally, the supplier advises using EDTA as the anticoagulant.

      도움이 되었습니까?

  6. Is the calibrator in this kit an acetylcholinesterase enzyme, or a colorimetric solution?

    1 답변
    1. The calibrator is not the enzyme, it is a dye that, when used as directed in the protocol, has an absorbance equivalent to 200U/L under assay conditions.

      도움이 되었습니까?

  7. Convert the AChE activity (units/L) into a units/mg of tissue value to represent the data?

    1 답변
    1. To calculate the enzyme activity in U/mg, follow these steps:
      AChE Activity = (A412 final – A412 initial) / (A412calibrator – A412 blank) × n × 200 × 0.0002 (U) Here, 0.0002 represents the volume (L) of the well. Specific Activity (U/mg) = AChE Activity (U) / tissue amount (mg)

      도움이 되었습니까?

  8. What is the difference between the two Acetylcholinesterase Activity Assay Kits MAK119 and CS0003?

    1 답변
    1. Product CS0003 and MAK119 are produced by different manufacturers. In addition, CS0003 is sufficient for 200 tests while product MAK119 is sufficient for 100 tests. The principles and detection range are the same for both products.
      The following is true for product CS0003:
      - Direct procedure for measuring AChE levels in a variety of samples such as serum and plasma.
      - Based on the Ellman method in which thiocholine, produced by AChE, reacts with 5,5'-dithiobis (2-nitrobenzoic acid) to form a colorimetric (412 nm) product, proportional to the AChE activity present.
      - The AChE activity is measured without the use of a calibration curve. The AChE Positive Control in the kit can be used to screen for AChE inhibitors.
      - This kit has a linear range of 10-600 units/liter of AChE activity.
      The following is true for product MAK119:
      - Direct assays of acetylcholinesterase activity in blood, serum, plasma, and other biological samples.
      - Based on an improved Ellman method, in which thiocholine produced by the action of acetylcholinesterase forms a yellow color with 5,5’-dithiobis(2-nitrobenzoic acid). The intensity of the product color, measured at 412 nm, is proportionate to the enzyme activity in the sample.
      - Detection range 10 to 600 U/L AChE activity in 96-well plate assay.

      도움이 되었습니까?

  9. Can I use this AChE kit to test inhibitory substances present in DMSO solution?

    1 답변
    1. This kit is to measure ACheE activity in blood, serum and plasma samples. It has not been tested to measure AChE levels in a solution of DMSO. If you wanted to test the effects of DMSO present in your sample, you will need to assay a positive control sample alongside a positive control sample spiked with the suspected interfering substance (in this case, DMSO).

      Bovine serum can be used as a positive control
      Assay buffer can be used as a negative control.

      Standards can be varying concentrations of acetylcholinesterase within the linear detection range of the kit (10 to 600 U/L AChE activity); one possible source of acetylcholinesterase can be from Sigma Aldrich C3389 (Acetylcholinesterase from electric eel, link: https://www.sigmaaldrich.com/US/en/product/sigma/c3389

      도움이 되었습니까?