The SCT125 is neither a pre-stain nor a loading dye. According to the data sheet, the recommendation is to first run the gel, and then immerse it in a 1 to 10,000 dilution of SCT125 post-electrophoresis. Instructions for its use can be found on the product's data sheet, found in the DOCUMENTATION section of the Product Detail Page: https://www.sigmaaldrich.com/product/mm/sct125#product-documentation
SCT125
GelGreen® Nucleic Acid Stain 10000X Water
GelGreen is a fluorescent nucleic acid stain designed to replace the highly toxic ethidium bromide (EtBr) for staining dsDNA, ssDNA or RNA in agarose gels or polyacrylamide gels.
동의어(들):
Fluorescent DNA gel stain
About This Item
추천 제품
양식
liquid
기술
PCR: suitable
solubility
water: soluble
적합성
suitable for nucleic acid staining
검출 방법
fluorometric
일반 설명
The dye is noncytotoxic and non-mutagenic at concentrations well above the working concentrations used in gel staining. GelGreen successfully passed environmental safety tests in compliance with CCR Title 22 Hazardous Waste Characterization, under which GelGreen is not classified as hazardous waste.
Spectral Properties
Absorbance: Standard Transilluminator (254 nm) such as a Dark Reader
Emission: Long path green filter such as a SYBR filter or GelStar filter.
애플리케이션
Cell Culture
Live Cell Dye
품질
Absorbance: Standard Transilluminator (254 nm) such as a Dark Reader
Emission: Long path green filter such as a SYBR filter or GelStar filter.
물리적 형태
저장 및 안정성
법적 정보
면책조항
Storage Class Code
10 - Combustible liquids
WGK
WGK 2
Flash Point (°F)
188.6 °F - (Dimethylsulfoxide)
Flash Point (°C)
87 °C - (Dimethylsulfoxide)
시험 성적서(COA)
제품의 로트/배치 번호를 입력하여 시험 성적서(COA)을 검색하십시오. 로트 및 배치 번호는 제품 라벨에 있는 ‘로트’ 또는 ‘배치’라는 용어 뒤에서 찾을 수 있습니다.
-
Is SCT125 used as a pre-stain mixed into the gel prior to the electrophoresis run, or is it a loading dye that should be added to the samples immediately before being loaded into the wells?
Is SCT125 used as a pre-stain mixed into the gel prior to the electrophoresis run, or is it a loading dye that should be added to the samples immediately before being loaded into the wells?
1 답변-
도움이 되었습니까?
-
-
Would gel green work for a gel reader that uses blue light instead of UV light? The excitation needs to be about 480 nm
1 답변-
Yes, this product compatible with either a 254 nm UV transilluminator or a gel reader equipped with visible light excitation (such as a 488 nm laser-based gel scanner or a Dark Reader).
도움이 되었습니까?
-