추천 제품
종 반응성(상동성에 의해 예측)
all
제조업체/상표
FlowCellect™
기술
flow cytometry: suitable
호환성
for use with EasyCyte 8HT
for use with EasyCyte Mini
for use with EasyCyte Plus
for use with EasyCyte
검출 방법
fluorometric
배송 상태
dry ice
일반 설명
Oxidative stress has been found to play a key role in a number of pathological disorders. To aid researchers studying this phenomenon Millipore has developed the FlowCellect Oxidative Stress Characterization Kit. This kit contains the chemical and immunological reagents necessary to detect carbonyl groups introduced onto proteins by reactive oxygen species (ROS). The test method involves derivatization of protein carbonyl groups with 2,4-dinitrophenylhydrazine (DNPH). This chemical reaction results in proteins being covalently coupled to DNP at their carbonyl sites. The DNP-derivatized proteins are then incubated with a FITC conjugated monoclonal antibody that specifically binds to the DNP moiety. Subsequent detection with a bench-top Guava EasyCyte Plus flow cytometer allows quantification of the extent of oxidative stress within cells. Although the assay and all of the kit components were optimized using a Guava instrument, any flow cytometer can be utilized provided it contains a blue laser (488 nm) light source.
애플리케이션
Research Category
Neuroscience
Neuroscience
성분
Anti-DNP -FITC
Derivatization Control Solution
5X Assay Buffer
DNPH Solution
10X Wash Buffer
User Manual
Derivatization Control Solution
5X Assay Buffer
DNPH Solution
10X Wash Buffer
User Manual
저장 및 안정성
Upon arrival the FITC conjugated anti-DNP antibody should be transferred to a -20°C freezer. The remaining kit components (FCCH025111-1) should be stored at 2 - 8ºC.
All kit components are stable for up to six (6) months from date of receipt if stored and handled appropriately.
All kit components are stable for up to six (6) months from date of receipt if stored and handled appropriately.
법적 정보
FlowCellect is a trademark of Luminex Corporation
면책조항
Unless otherwise stated in our catalog or other company documentation accompanying the product(s), our products are intended for research use only and are not to be used for any other purpose, which includes but is not limited to, unauthorized commercial uses, in vitro diagnostic uses, ex vivo or in vivo therapeutic uses or any type of consumption or application to humans or animals.
시험 성적서(COA)
제품의 로트/배치 번호를 입력하여 시험 성적서(COA)을 검색하십시오. 로트 및 배치 번호는 제품 라벨에 있는 ‘로트’ 또는 ‘배치’라는 용어 뒤에서 찾을 수 있습니다.
이미 열람한 고객
Oncotarget, 7(13), 15868-15884 (2016-02-26)
Glioblastoma multiforme (GBM) is the most aggressive CNS tumor and is characterized by a very high frequency of clinical relapse after therapy and thus by a dismal prognosis, which strongly compromises patients survival. We have recently identified the small molecule
자사의 과학자팀은 생명 과학, 재료 과학, 화학 합성, 크로마토그래피, 분석 및 기타 많은 영역을 포함한 모든 과학 분야에 경험이 있습니다..
고객지원팀으로 연락바랍니다.