추천 제품
조인트
Joints threaded cap hard plastic (NS 29)
기술
thin layer chromatography (TLC): suitable
크기
250 mL
유사한 제품을 찾으십니까? 방문 제품 비교 안내
일반 설명
Connect using the barb end to a low-pressure gas or air source of <5 psi. By positioning your thumb over the vent hole you can control the spray pattern.
애플리케이션
- Aldrich® flask-type sprayer connected to a nitrogen gas line was used as to immobilize the coatings on metal fiber core.
- Aldrich flask-type sprayer was used as to coat a thin layer of catalyst on fiberglass cloth.
- Aldrich flask-type sprayer was used to prepare polyacrylonitrile-polystyrene-divinylbenzene (PAN-PS-DVB) and polyacrylonitrile-phenylboronic acid (PAN-PBA) coating for automated 96-blades (thin-film) solid phase microextraction (SPME) system.
법적 정보
Aldrich is a registered trademark of Sigma-Aldrich Co. LLC
시험 성적서(COA)
제품의 로트/배치 번호를 입력하여 시험 성적서(COA)을 검색하십시오. 로트 및 배치 번호는 제품 라벨에 있는 ‘로트’ 또는 ‘배치’라는 용어 뒤에서 찾을 수 있습니다.
이미 열람한 고객
Journal of chromatography. A, 1261, 99-106 (2012-08-14)
A new thin film microextraction (TFME) configuration based on C(18) thin film was optimized to improve solid phase microextraction (SPME) sensitivity and extraction kinetics for in vivo determinations of trace pharmaceuticals in fish tissue. Optimization of SPME involved increasing sampler
Journal of the Air & Waste Management Association (1995), 52(7), 845-854 (2002-07-26)
Photocatalytic oxidation (PCO) of volatile organic compounds (VOCs) is a highly attractive alternative technology for purification and deodorization of indoor air. The main objectives of this study were to demonstrate that a common fluorescent visible light (FVL) lamp can be
Analytical chemistry, 83(15), 6018-6025 (2011-06-30)
Biocompatible C18-polyacrylonitrile (PAN) coating was used as the extraction phase for an automated 96-blade solid phase microextraction (SPME) system with thin-film geometry. Three different methods of coating preparation (dipping, brush painting, and spraying) were evaluated; the spraying method was optimum
Journal of chromatography. A, 1261, 91-98 (2012-07-25)
This work presents the development and evaluation of biocompatible polyacrylonitrile-polystyrene-divinylbenzene (PAN-PS-DVB) and polyacrylonitrile-phenylboronic acid (PAN-PBA) coatings for automated 96-blades (thin-film) solid phase microextraction (SPME) system, using high performance liquid chromatography (HPLC) coupled with tandem mass spectrometry (MS/MS). The SPME condition
자사의 과학자팀은 생명 과학, 재료 과학, 화학 합성, 크로마토그래피, 분석 및 기타 많은 영역을 포함한 모든 과학 분야에 경험이 있습니다..
고객지원팀으로 연락바랍니다.