コンテンツへスキップ
Merck

LC/MS/MS Analysis of Aflatoxins in Cannabis on Ascentis® Express 2.7 μm Phenyl-Hexyl after Cleanup using Supel Tox AflaZea SPE

LC/MS/MS Analysis of Aflatoxins in Cannabis on Ascentis® Express 2.7 μm Phenyl-Hexyl after Cleanup using Supel™ Tox AflaZea SPE application for LC-MS, application for SPE

材料

付属品

製品番号
詳細
価格

Black plastic caps

Solid top, white rubber liner, thread for 8-425, pkg of 1000 ea

Visiprep SPEバキュームマニホールド

DL (Disposable Liner), 12-port model

Visiprep DLマニホールド用使い捨てライナー(57044および57265用)

PTFE, pk of 100

バイアル、スクリュートップ、シラン処理済み

volume 2 mL, amber glass vial, O.D. × H × I.D. 12 mm × 32 mm × 4.6 mm

QuEChERS Shaker and Rack Starter Kit

AC/DC input 115 V AC (USA Compatible Plug)

分析カラム

製品番号
詳細
価格

Ascentis® Express フェニルヘキシル、2.7 μm HPLCカラム

2.7 μm particle size, L × I.D. 5 cm × 2.1 mm

標準

製品番号
詳細
価格

アフラトキシンMix 4成分 溶液

analytical standard

CONDITIONS

sample preparation

Solid Phase Extraction

sample/matrix

cannabis extract spiked with aflatoxins at corresponding concentrations of 6 ppb each (for Aflatoxin B2 and G2) and 24 ppb each (for Afltoxin B1 and G1) in cannabis

SPE tube/cartridge

Supel Tox AflaZea SPE, 6 mL (55314-U)

sample addition

2 mL of sample extract

elution

apply strong vacuum and collect the sample into plastic tube

eluate post-treatment

dilute 0.2 mL of the extract with 0.8 mL distilled water and mix well

column

Ascentis Express Phenyl-Hexyl, 5 cm x 2.1 mm I.D., 2.7 μm particles (53334-U)

mobile phase

[A] 5 mM ammonium formate with 1% formic acid in water; [B] 5 mM ammonium formate with 1% formic acid in methanol

gradient

30% B to 60% B in 3 min; to 100% B in 2 in; held at 100% B for 2 min; to 30% B in 0.1 min; held at 30% B for 1.4 min

flow rate

0.4 mL/min

pressure

5511 psi (380 bar)

column temp.

40 °C

detector

MS, ESI(+), MRM 331.3/189.0, 329.1/243.0, 315.9/259.0, 313.1/241.0

injection

10 μL

詳細

アナリシスノート

The complex composition of cannabis makes it difficult to apply sample cleanup methods commonly used for other commodities. In this application, interference removal Supel Tox AflaZea SPE was used for sample cleanup providing quick and effective sample preparation prior to mass spectrometric analysis. Sample comprised 0.5 g of finely ground cannabis mixed with 10 mL of 84:16 acetonitrile:water for 30 minutes and centrifuged. It is recommended to use silanized glass vials for this analysis.

法的情報

Ascentis is a registered trademark of Merck KGaA, Darmstadt, Germany
Supel is a trademark of Sigma-Aldrich Co. LLC