  • Enhancement for trace analysis of sulfonamide antibiotics in water matrices using bar adsorptive microextraction (BAμE).

Enhancement for trace analysis of sulfonamide antibiotics in water matrices using bar adsorptive microextraction (BAμE).

Journal of pharmaceutical and biomedical analysis (2016-08-16)
A H Ide, S M Ahmad, N R Neng, J M F Nogueira
要旨

In this study, the enhancement for trace analysis of sulfonamide antibiotics (sulfathiazole, sulfamethoxazole and sulfadimethoxine) and trimethoprim in water matrices is proposed using bar adsorptive microextraction combined with micro-liquid desorption followed by high-performance liquid chromatography with diode array detection (BAμE-μLD/HPLC-DAD). By comparing different polymers and activated carbons as sorbent coatings for BAμE, the polystyrene-divinylbenzene polymer (PS-DVB) showed the best selectivity for the compounds under study. Assays performed through BAμE(PS-DVB)-μLD on 25mL of ultrapure water samples spiked at the 8.0μgL(-1) level showed recoveries ranging from 63.8±1.5% to 84.2±1.9%, under optimized experimental conditions. The validated method provided satisfactory limits of detection (0.08-0.16μgL(-1)) and good linear dynamic ranges (0.16-8.00μgL(-1)) with determination coefficients higher than 0.9958. The proposed analytical methodology was applied to real matrices, such as tap, estuarine and wastewater samples using the standard addition method. It showed to be easy to implement, with good reproducibility, sensitivity and requiring small amount of sample. Furthermore, negligible consumption of organic solvents was used in compliance with the green analytical chemistry principles. When compared to other well-established microextraction approaches, BAμE demonstrated better performance concerning recovery yields and sensitivity.

材料
製品番号
ブランド
製品内容

Supelco
SPMEファイバーアセンブリー ジビニルベンゼン/カルボキセン/ポリジメチルシロキサン (DVB/CAR/PDMS), needle size 24 ga, StableFlex
Supelco
SPMEファイバーアセンブリー ジビニルベンゼン/カルボキセン/ポリジメチルシロキサン (DVB/CAR/PDMS), needle size 24 ga, for use with manual holder
Supelco
SPMEファイバーアセンブリー ジビニルベンゼン/カルボキセン/ポリジメチルシロキサン (DVB/CAR/PDMS), needle size 23 ga, StableFlex, for use with autosampler
Supelco
SPMEファイバーアセンブリー ジビニルベンゼン/カルボキセン/ポリジメチルシロキサン (DVB/CAR/PDMS), needle size 23 ga, StableFlex, for use with manual holder or autosampler, fiber L 2 cm
Supelco
SPMEファイバーアセンブリー ジビニルベンゼン/カルボキセン/ポリジメチルシロキサン (DVB/CAR/PDMS), needle size 24 ga, StableFlex, for use with autosampler
Supelco
SPMEファイバーアセンブリー ポリジメチルシロキサン(PDMS), df 100 μm(PDMS, needle size 24 ga, for use with manual holder
Supelco
SPMEファイバーアセンブリー ポリジメチルシロキサン(PDMS), df 100 μm(PDMS, for use with autosampler, needle size 23 ga
Supelco
SPMEファイバーアセンブリー ポリジメチルシロキサン(PDMS), df 100 μm(PDMS, for use with autosampler, needle size 24 ga
Supelco
SPMEファイバー・アセンブリカルボキセン/ポリジメチルシロキサン(CAR/PDMS), df 75 μm(CAR/PDMS, for use with manual holder, needle size 24 ga
Supelco
SPMEファイバー・ポリジメチルシロキサン/ジビニルベンゼン(PDMS/DVB), df 65 μm(PDMS/DVB, needle size 24 ga, StableFlex, for use with autosampler
Supelco
SPMEファイバー・アセンブリカルボキセン/ポリジメチルシロキサン(CAR/PDMS), df 85 μm(CAR/PDMS, needle size 23 ga, StableFlex, for use with autosampler
Supelco
SPMEファイバー・ポリジメチルシロキサン/ジビニルベンゼン(PDMS/DVB), df 65 μm(PDMS/DVB, needle size 24 ga, for use with manual holder
Supelco
SPMEファイバー・アセンブリカルボキセン/ポリジメチルシロキサン(CAR/PDMS), df 75 μm(CAR/PDMS, needle size 24 ga, for use with autosampler
Supelco
SPMEファイバー・アセンブリカルボキセン/ポリジメチルシロキサン(CAR/PDMS), df 85 μm(CAR/PDMS, needle size 24 ga, StableFlex, for use with autosampler
Supelco
SPMEファイバーアセンブリー ポリアクリラート (PA), df 85 μm(PA, for use with autosampler, needle size 23 ga
Supelco
SPMEファイバー・ポリジメチルシロキサン/ジビニルベンゼン(PDMS/DVB), df 65 μm(PDMS/DVB, needle size 23 ga, PDMS/DVB StableFlex, for use with autosampler
Supelco
SPMEファイバーアセンブリー ポリアクリラート (PA), df 85 μm(PA, for use with autosampler, needle size 24 ga
Supelco
SPMEファイバー・アセンブリカルボキセン/ポリジメチルシロキサン(CAR/PDMS), df 85 μm(CAR/PDMS, needle size 24 ga, for use with manual holder, StableFlex fiber
Supelco
SPMEファイバー・ポリジメチルシロキサン/ジビニルベンゼン(PDMS/DVB), df 65 μm(PDMS/DVB, needle size 24 ga, StableFlex, for use with manual holder
Supelco
SPMEファイバーアセンブリー ポリジメチルシロキサン(PDMS), df 100 μm(PDMS, for use with manual holder, needle size 23 ga
Supelco
SPMEファイバー・ポリジメチルシロキサン/ジビニルベンゼン(PDMS/DVB), df 65 μm(PDMS/DVB, needle size 24 ga, for use with autosampler
Supelco
SPMEファイバー・アセンブリカルボキセン/ポリジメチルシロキサン(CAR/PDMS), df 75 μm(CAR/PDMS, needle size 23 ga, for use with autosampler
Supelco
SPME StableFlexファイバー組み合わせキット, for use with manual holder
Supelco
SPMEファイバーアセンブリ、Carbowax・ポリエチレングリコール(PEG)コーティング, needle size 23 ga, df 60 μm(PEG, for use with autosampler
Supelco
SPMEファイバー・ポリジメチルシロキサン/ジビニルベンゼン(PDMS/DVB), df 65 μm(PDMS/DVB, for use with autosampler, needle size 23 ga
Supelco
SPMEファイバー・アセンブリカルボキセン/ポリジメチルシロキサン(CAR/PDMS), df 75 μm(CAR/PDMS, needle size 23 ga, for use with manual holder
Supelco
SPME StableFlexファイバー組み合わせキット, needle size 23 ga, for use with autosampler
Supelco
SPMEファイバー・ポリジメチルシロキサン/ジビニルベンゼン(PDMS/DVB), fused silica fiber, df 65 μm(PDMS/DVB, for use with manual holder, needle size 23 ga
Supelco
SPMEファイバー組み合わせキット4, for use with manual holder, size 24 ga
Supelco
SPMEファイバーアセンブリー ポリアクリラート (PA), df 85 μm(PA, for use with manual holder, needle size 24 ga