コンテンツへスキップ
Merck
  • Solid-phase extraction coupled with ultra high performance liquid chromatography and electrospray tandem mass spectrometry for the highly sensitive determination of five iodinated X-ray contrast media in environmental water samples.

Solid-phase extraction coupled with ultra high performance liquid chromatography and electrospray tandem mass spectrometry for the highly sensitive determination of five iodinated X-ray contrast media in environmental water samples.

Journal of separation science (2015-04-03)
Xia Li, Junjian Hu, Daqiang Yin, Xialin Hu
要旨

A highly sensitive method based on solid-phase extraction and ultra high performance liquid chromatography with electrospray tandem mass spectrometry has been developed for simultaneous determination of five iodinated X-ray contrast media in environmental water samples. Various solid-phase extraction cartridges have been evaluated and a combination of LiChrolute EN and ENVI-Carb solid phase extraction cartridges was selected for sample enrichment. The method was comprehensively validated on ground water, tap water, surface water, drinking water, and waste water by the conventional procedures: linearity, method detection limits, accuracy and precision, matrix effects. Good linearity (R(2) > 0.999), low detection limits (0.4-8.1 ng/L), satisfactory recoveries (55.1-109.5%) and precision (0.8-10.0% for intra-day precisions and 0.6-16.5% for inter-day precisions) were obtained for all the target compounds. Iopamidol, iohexol, and diatrizoate in some matrices were affected by matrix effects, which were slightly eased by using the isotope-labeled internal standard. The developed method was successfully applied for real samples collected in Shanghai, China, with detected concentrations up to 2200 ± 200 and 9000 ± 1000 ng/L for iohexol and iopamidol, respectively.

材料
製品番号
ブランド
製品内容

Sigma-Aldrich
アセトニトリル, anhydrous, 99.8%
Sigma-Aldrich
Histodenz, nonionic density gradient medium
Sigma-Aldrich
メタノール, anhydrous, 99.8%
Sigma-Aldrich
メタノール, JIS special grade, ≥99.8%
Sigma-Aldrich
メタノール, SAJ first grade, ≥99.5%
Sigma-Aldrich
アセトニトリル, electronic grade, 99.999% trace metals basis
Sigma-Aldrich
アセトニトリル 溶液, contains 0.1 % (v/v) formic acid, suitable for HPLC
Sigma-Aldrich
メタノール, SAJ special grade
Sigma-Aldrich
メタノール, suitable for HPLC
Sigma-Aldrich
アセトニトリル, ≥99.8%, suitable for HPLC
Sigma-Aldrich
アセトニトリル 溶液, contains 0.1 % (v/v) trifluoroacetic acid, suitable for HPLC
Supelco
Supel QuE, PSA/ENVI-Carb Tube 2, pk of 50, suitable for EN 15662:2008 per BS, centrifuge tube volume 15 mL , Shaker Compatible
Supelco
Supel QuE, PSA/ENVI-Carb (EN) Cleanup Tube 2, pack of 100, suitable for EN 15662:2008 per BS
Sigma-Aldrich
メタノール, NMR reference standard
Sigma-Aldrich
アセトニトリル, ≥99.8%, for residue analysis, JIS 300
Supelco
Supel QuE, PSA/ENVI-Carb Tube 1, pk of 50, suitable for EN 15662:2008 per BS, centrifuge tube volume 15 mL , Shaker Compatible
Sigma-Aldrich
アセトニトリル, JIS special grade, ≥99.5%
Sigma-Aldrich
アセトニトリル, ≥99.5%, ACS reagent
Supelco
Supel QuE, PSA/C18/ENVI-Carb Tube, pk of 50, AOAC® 2007.01, centrifuge tube volume 15 mL , Shaker Compatible
Sigma-Aldrich
Methanol-12C, 99.95 atom % 12C
Supelco
メタノール 溶液, contains 0.10 % (v/v) formic acid, UHPLC, suitable for mass spectrometry (MS), ≥99.5%
Sigma-Aldrich
メタノール, JIS 300, ≥99.8%, for residue analysis
Supelco
Supel QuE, PSA/C18/ENVI-Carb Tube, pack of 100, AOAC® 2007.01
Supelco
Supel QuE, PSA/ENVI-Carb (EN) Cleanup Tube 1, pack of 100, suitable for EN 15662:2008 per BS
Sigma-Aldrich
メタノール, HPLC Plus, ≥99.9%, poly-coated bottles
Sigma-Aldrich
アセトニトリル, SAJ first grade, ≥99.0%
Sigma-Aldrich
アセトニトリル, for chromatography
Sigma-Aldrich
アセトニトリル, ≥99.8%, for residue analysis, JIS 1000
Sigma-Aldrich
アセトニトリル 溶液, contains 0.05 % (w/v) ammonium formate, 5 % (v/v) water, 0.1 % (v/v) formic acid, suitable for HPLC
Sigma-Aldrich
アセトニトリル, for residue analysis, JIS 5000