  • High-throughput automatic flow method for determination of trace concentrations of aluminum in dialysis concentrate solutions using salicylaldehyde picolinoylhydrazone as a turn-on fluorescent probe.

High-throughput automatic flow method for determination of trace concentrations of aluminum in dialysis concentrate solutions using salicylaldehyde picolinoylhydrazone as a turn-on fluorescent probe.

Talanta (2014-12-02)
Arnau Garau, Miquel Oliver, María Rosende, Manuel P Mánuel-Vez, Manuel Miró
要旨

A simple and expedient flow-based assembly capitalizing on programmable flow is herein proposed for reliable determination of trace level concentrations of aluminum as a potential contaminant in dialysis concentrate solutions without any prior sample clean-up/preconcentration procedure. Using salicylaldehyde picolinoylhydrazone in weakly acidic media as a turn-on fluorescent probe, the manifold is devised to handle three samples concurrently in stopped-flow reaction mode for simultaneous improvement of the analytical sensitivity and sample throughput. Analytical parameters influencing the sensitivity and repeatability of the assays, namely, probe concentration, reaction temperature and reaction time were investigated using a multivariate optimization protocol composed of a full factorial screening design followed by a Doehlert matrix model. The analysis of the Pareto chart and surface response revealed that the reaction time and amount of fluorescent probe were critical parameters for reliable assays of aluminum at the low ng mL(-1) level. Under the optimized chemical and physical variables, a detection limit of 1.1ngmL(-1) Al(III) at the 3s(blank) level, relative standard deviations better than 1.0%, a dynamic linear range of 5.0-80 ng mL(-1) and a sample throughput up to 25 h(-1) were obtained with no need for either sample preconcentration or the use of organized supramolecular systems. Demonstrated with the analysis of hemodialysis and peritoneal concentrate solutions, and dialysis waters, the flow-through method copes with the requirements of regulatory bodies (e.g., European Pharmacopeia) for quality control of aluminum in high salinity containing dialysis concentrates.

材料
製品番号
ブランド
製品内容

Sigma-Aldrich
酢酸, glacial, ACS reagent, ≥99.7%
Sigma-Aldrich
酢酸, glacial, ReagentPlus®, ≥99%
Sigma-Aldrich
酢酸, glacial, ≥99.99% trace metals basis
Sigma-Aldrich
酢酸 溶液, suitable for HPLC
Sigma-Aldrich
酢酸, glacial, puriss., meets analytical specification of Ph. Eur., BP, USP, FCC, 99.8-100.5%
Sigma-Aldrich
ヒドラジン 溶液, 35 wt. % in H2O
Sigma-Aldrich
酢酸, for luminescence, BioUltra, ≥99.5% (GC)
USP
氷酢酸, United States Pharmacopeia (USP) Reference Standard
Sigma-Aldrich
酢酸, ≥99.5%, FCC, FG
Sigma-Aldrich
酢酸, natural, ≥99.5%, FG
Sigma-Aldrich
5α-アンドロスタン-17β-オール-3-オン, ≥97.5%
Sigma-Aldrich
酢酸, glacial, puriss., 99-100%
Supelco
酢酸, analytical standard
Sigma-Aldrich
ヒドラジン 溶液, 1.0 M in THF
Sigma-Aldrich
酢酸, JIS special grade, ≥99.7%
Sigma-Aldrich
酢酸, ≥99.7%
Sigma-Aldrich
ヒドラジン 溶液, 1.0 M in ethanol
Sigma-Aldrich
5α-アンドロスタン-17β-オール-3-オン, purum, ≥99.0% (TLC)
Sigma-Aldrich
酢酸, SAJ first grade, ≥99.0%
Sigma-Aldrich
酢酸 溶液, 1 M, 1 N
Sigma-Aldrich
ヒドラジン 溶液, 1 M in acetonitrile
Sigma-Aldrich
エチル 2-ピコリネート, 99%
Sigma-Aldrich
酢酸, ≥99.7%, SAJ super special grade
Sigma-Aldrich
酢酸, ≥99.7%
Sigma-Aldrich
酢酸, ≥99.7%, for titration in non-aqueous medium
Sigma-Aldrich
Acetic acid-12C2, 99.9 atom % 12C
Millipore
Bifido Selective Supplement B, suitable for microbiology
Sigma-Aldrich
酢酸, 99.5-100.0%
Sigma-Aldrich
酢酸 溶液, SAJ first grade, 27.0-33.0%
Sigma-Aldrich
酢酸, ≥99.7%, suitable for amino acid analysis