コンテンツへスキップ
Merck

Reactions of latent prints exposed to blood.

Forensic science international (2012-11-28)
Nicole Praska, Glenn Langenburg
要旨

We explored whether an undeveloped latent print (fingermark) exposed to blood and later developed by enhancement with blood reagents such as amido black (AB) or leucocrystal violet (LCV) could appear as a genuine blood mark. We examined three different experimental conditions. In Experiment I, fingermark residue only was tested, as a control to confirm that fingermark residue alone does not react with the blood reagents AB and LCV. Experiment II investigated whether latent fingermarks exposed to blood dilutions could be treated with AB or LCV and subsequently appear as a genuine blood mark enhanced with AB or LCV. Experiment III tested whether latent fingermarks exposed to whole blood could be processed with AB or LCV and subsequently appear as a genuine blood mark enhanced with AB or LCV. The present study found that indeed, fingermark residue alone does not react with the blood reagents AB and LCV. In Experiment II, an interaction occurred between the fingermark residue and the diluted blood that caused the ridges to appear a red color. In the present study, this interaction is called a faux blood mark. While the faux blood mark phenomenon occurred most often following exposure to diluted blood, it did not occur consistently, and a predictable pattern could not be established. However, the reaction occurred more frequently following extended fingermark residue drying times. Faux blood marks are distinguishable from genuine blood marks prior to enhancement with blood reagents. Following treatment with blood reagents, it became increasingly difficult to determine whether the enhanced mark was a genuine blood print or a latent fingermark exposed to diluted blood. Latent fingermarks exposed to whole blood often resulted in a void prior to enhancement, but following treatment with blood reagents, were difficult to distinguish from a genuine blood mark enhanced with blood reagents.

材料
製品番号
ブランド
製品内容

Sigma-Aldrich
クリスタルバイオレット溶液 溶液, 1%, aqueous solution
Sigma-Aldrich
クリスタルバイオレット, certified by the Biological Stain Commission
Sigma-Aldrich
クリスタルバイオレット, ACS reagent, ≥90.0% anhydrous basis
Sigma-Aldrich
クリスタルバイオレット溶液 溶液
Sigma-Aldrich
アミドブラック染色液2×, electrophoresis reagent
Sigma-Aldrich
クリスタルバイオレット溶液 溶液
Sigma-Aldrich
ナフトールブルーブラック, BioReagent, suitable for electrophoresis
Sigma-Aldrich
クリスタルバイオレット, for microscopy (Bact., Bot., Hist., Vit.), indicator (pH 0.1-2.0)
Supelco
クリスタルバイオレット, VETRANAL®, analytical standard
Sigma-Aldrich
ナフトールブルーブラック, Dye content 80 %
Sigma-Aldrich
Gentian Violet, meets USP testing specifications
Sigma-Aldrich
ゲンチアナバイオレット 溶液
Sigma-Aldrich
クリスタルバイオレット, indicator for the determination of the redox potential, S. No.: 785
Sigma-Aldrich
クリスタルバイオレット, JIS special grade
Sigma-Aldrich
グラム・ハッカー染色液(I)
Sigma-Aldrich
ナフトールブルーブラック, Dye content ~50 %
Sigma-Aldrich
クリスタルバイオレット, SAJ first grade
Sigma-Aldrich
クリスタルバイオレット, SAJ special grade