If this product has an expiration or retest date, it will be shown on the Certificate of Analysis (COA, CofA). If there is no retest or expiration date listed on the product's COA, we do not have suitable stability data to determine a shelf life. For these products, the only date on the COA will be the release date; a retest, expiration, or use-by-date will not be displayed.
For all products, we recommend handling per defined conditions as printed in our product literature and website product descriptions. We recommend that products should be routinely inspected by customers to ensure they perform as expected.
For products without retest or expiration dates, our standard warranty of 1 year from the date of shipment is applicable.
For more information, please refer to the Product Dating Information document: https://www.sigmaaldrich.com/deepweb/assets/sigmaaldrich/marketing/global/documents/449/386/product-dating-information-mk.pdf
¥254,000
出荷可能日2025年4月17日詳細
おすすめの製品
製品名
SUPELCOGEL™ C610H、6%架橋HPLCカラム, 9 μm particle size, L × I.D. 30 cm × 7.8 mm
物質
stainless steel column
品質水準
認証
suitable for USP L17
製品種目
SUPELCOGEL™
特徴
endcapped: no
包装
1 ea of
パラメーター
85 °C max. temp.
テクニック
HPLC: suitable
L × 内径
30 cm × 7.8 mm
Matrix
sulfonated polystyrene/divinylbenzene, spherical particle platform
polymeric
粒径
9 μm
分離法
ion exclusion
類似した製品をお探しですか? 訪問 製品比較ガイド
関連するカテゴリー
詳細
法的情報
ガードカートリッジ
保管分類コード
11 - Combustible Solids
WGK
WGK 3
引火点(°F)
Not applicable
引火点(℃)
Not applicable
個人用保護具 (PPE)
Eyeshields, Gloves, type N95 (US)
適用法令
試験研究用途を考慮した関連法令を主に挙げております。化学物質以外については、一部の情報のみ提供しています。 製品を安全かつ合法的に使用することは、使用者の義務です。最新情報により修正される場合があります。WEBの反映には時間を要することがあるため、適宜SDSをご参照ください。
Jan Code
59320-BULK-U:
59320-U:
最新バージョンのいずれかを選択してください:
この製品を見ている人はこちらもチェック
資料
Learn more about Bioethanol as a renewable, alternative fuel traditionally produced by the yeast fermentation of sugar.
プロトコル
Increasing corn-to-ethanol conversion and production yield drive discussions on fuel ethanol's economic and environmental viability in biofuel.
Organic acid measurement complements wine quality assessment, influencing color and taste through fermentation control.
-
How can I determine the shelf life / expiration / retest date of this product?
1 回答-
役に立ちましたか?
-
-
How is shipping temperature determined? And how is it related to the product storage temperature?
1 回答-
Products may be shipped at a different temperature than the recommended long-term storage temperature. If the product quality is sensitive to short-term exposure to conditions other than the recommended long-term storage, it will be shipped on wet or dry-ice. If the product quality is NOT affected by short-term exposure to conditions other than the recommended long-term storage, it will be shipped at ambient temperature. As shipping routes are configured for minimum transit times, shipping at ambient temperature helps control shipping costs for our customers. For more information, please refer to the Storage and Transport Conditions document: https://www.sigmaaldrich.com/deepweb/assets/sigmaaldrich/marketing/global/documents/316/622/storage-transport-conditions-mk.pdf
役に立ちましたか?
-
-
What solutiuon can i use to clean this column?
1 回答-
Cleaning Procedure:
Metal contamination is indicated by shortened retention times and/or skewed peaks. Flush the column in the reverse flow direction following column-specific conditions listed below; do NOT connect the column to the detector during this process. Monitor the system closely to ensure that the maximum pressures are not exceeded. Note that up to 20% ethanol or up to 5% isopropanol may be substituted for the solvents recommended below.
SUPELCOGEL K Mobile Phase: 0.1M K2HPO4 Flow: 0.1 mL/min. Temperature: 85 °C Time: 4-16 hours
SUPELCOGEL Pb & 8 Pb Mobile Phase: 0.1M Pb(NO3)2 Flow: 0.1 mL/min. Temperature: 85 °C Time: 4-16 hours
SUPELCOGEL Ca & 8 Ca Mobile Phase: 0.1M Ca(NO3)2 at a pH of 6.3 Flow: 0.1 mL/min. Temperature: 85 °C Time: 4-16 hours
SUPELCOGEL H, C-610H, C-611, & 8H Mobile Phase: 10/90 CH3CN/0.01NH3PO4 Flow: 0.1 mL/min. Time: 3-4 hours at 25 °C
SUPELCOGEL Ag1 & Ag2 No recommended cleaning procedures.Any additional cleaning procedures are as a last resort to prolong the column life, because the addition of organic solvents will cause the resin to swell resulting in an increase in pressure. Monitor the system closely to insure that the maximum pressures are not exceeded. To remove organic contamination, pump the columns in reverse flow at 0.1 mL/min. with 5:95 acetonitrile:water at 25 °C for 4 hours.
役に立ちましたか?
-
-
What is the Department of Transportation shipping information for this product?
1 回答-
Transportation information can be found in Section 14 of the product's (M)SDS.To access the shipping information for this material, use the link on the product detail page for the product.
役に立ちましたか?
-
-
What is the % crosslinkage of the SUPELCOGEL Columns?
1 回答-
All SUPELCOGEL resins are 6% crosslinked, except the SUPELCOGEL Ag2, which is 4%.
役に立ちましたか?
-
-
How does the Supelcogel™ H differ from the Supelcogel™ C-610H?
1 回答-
Both the Supelcogel™ H and the Supelcogel™ C-610H are microparticulate, macroporous, polystyrene resin columns designed for ion exchange separation of organic acids, carbohydrates, sugar alcohols, and fermentation products. The C-610H is manufactured with a slightly higher cross linkage. Maximum temperature for the Supelcogel™ H is 90° C and for Supelcogel™ C-610H is 60° C. Of the two, only the Supelcogel™ H is available in the 25cm x 4.6mm hardware.
役に立ちましたか?
-
アクティブなフィルタ
ライフサイエンス、有機合成、材料科学、クロマトグラフィー、分析など、あらゆる分野の研究に経験のあるメンバーがおります。.
製品に関するお問い合わせはこちら(テクニカルサービス)