The SLB-5ms excels in several performance criteria.· Low Bleed. The highly crosslinked silphenylene polymer chemistry reduces column bleed to a very low level, resulting in greater signal-to-noise level, allowing lower detection levels.· Inertness. The proprietary surface deactivation reduces interactions between analytes and the column surface, resulting in sharper peak shapes, allowing lower detection levels.· Durability. With the highest published maximum allowable operating temperature (MAOT) of any -5ms column, SLB-5ms columns are designed for long life.· Consistency. Innovative manufacturing processes result in decreased column variability, ensuring that the next column is as good as the last.
おすすめの製品
物質
fused silica
品質水準
認証
Standard Method 6040D
EN 2005/108/EC
EPA 610,625,8015,8082,8100,8141,8270,OLM04.2 SVOA
EPA TO-13,IP-8,8270,525.2,608.1/608.2,608/8081/OLM04.2 PEST
JMHLW
NIOSH 2530,5503
OSHA 62
meets requirements for USP G27 and G36
suitable for EPA 1613
法規制遵守
FDA LIB 4423
パラメーター
-60-340 °C temperature (isothermal)
-60-360 °C temperature (programmed)
β値
250
df
0.10 μm
テクニック
GC/MS: suitable
gas chromatography (GC): suitable (fast GC)
L × 内径
10 m × 0.10 mm
マトリックス活性基
Bonded and highly crosslinked; silphenylene polymer virtually equivalent in polarity to poly(5% diphenyl/95% dimethyl siloxane) phase
アプリケーション
agriculture
chemicals and industrial polymers
cleaning products
clinical
cosmetics
environmental
flavors and fragrances
food and beverages
forensics and toxicology
industrial hygiene
life science and biopharma
personal care
petroleum
pharmaceutical (small molecule)
カラムタイプ
capillary non-polar
類似した製品をお探しですか? 訪問 製品比較ガイド
詳細
USPコード:このカラムはUSP G27およびG36の要件に適合しています。
相:
- 結合済みかつ高度に架橋済み
- シルフェニレンポリマーは、実質的にポリ(5% ジフェニル/95%ジメチルシロキサン)と等価な極性を持っています。
- ≤内径0.32 mm:-60°C~340°C(等温)または360°C(プログラム温度)
- ≥内径0.53 mm:-60°C~330°C(等温)または340°C(プログラム温度)
その他情報
法的情報
アプリケーション
資料
The analysis of melamine and related compounds in dog food with the use of more economical gas chromatography-mass spectrometry (GC-MS) instrumentation.
プロトコル
Citrus essential oils hold significant economic value. These intricate substances find primary use in the food, beverage, cosmetic, and perfume industries.
GC Analysis of Sweet Orange Essential Oil on SLB®-5ms (10 m x 0.10 mm I.D., 0.10 μm), Fast GC Analysis
関連コンテンツ
This page is intended to make it easier to find the consumables you need based on the analytical method you’re using. Methods included on this page come from the EPA, Standard Methods and ASTM.
Chromatograms
suitable for GCsuitable for GCsuitable for GCsuitable for GC表示を増やす-
What are the benefits of the SLB™-5ms Capillary GC Column over other manufacturers’ -5ms columns?
1 回答-
役に立ちましたか?
-
-
Who uses SLB™-5ms Capillary GC Columns?
1 回答-
Any analyst with the need for a non-polar column. Some applications include boiling point separations, GC-MS analyses of semivolatiles, and GC-ECD analyses of pesticides/PCBs. It is estimated that non-polar columns account for 51% of the worldwide column market.
役に立ちましたか?
-
-
What if my method does not allow me to change to SLB™-5ms Capillary GC Columns?
1 回答-
These methods typically specify a 5-type column (DB-5 or equivalent). The SLB-5ms satisfies that requirement.
役に立ちましたか?
-
-
Would you recommend SLB™-5ms Capillary GC Columns for all applications instead of Equity-5, SPB-5, PTE-5, MDN-5, and MDN-5S?
1 回答-
Yes.
役に立ちましたか?
-
-
What is the Department of Transportation shipping information for this product?
1 回答-
Transportation information can be found in Section 14 of the product's (M)SDS.To access the shipping information for this material, use the link on the product detail page for the product.
役に立ちましたか?
-
-
How does the SLB™-5ms Capillary GC Column differ from our other 5-type columns?
1 回答-
Many of our other 5-type columns (Equity-5, SPB-5, PTE-5, MDN-5, and MDN-5S) incorporate a siloxane polymer (backbone comprised of Si and O atoms only, side groups are either methyl or phenyl). The SLB-5ms column incorporates a silphenylene polymer (backbone comprised of Si and O atoms plus some phenyl groups, side groups are either methyl or phenyl).
役に立ちましたか?
-
アクティブなフィルタ
ライフサイエンス、有機合成、材料科学、クロマトグラフィー、分析など、あらゆる分野の研究に経験のあるメンバーがおります。.
製品に関するお問い合わせはこちら(テクニカルサービス)