If this product has an expiration or retest date, it will be shown on the Certificate of Analysis (COA, CofA). If there is no retest or expiration date listed on the product's COA, we do not have suitable stability data to determine a shelf life. For these products, the only date on the COA will be the release date; a retest, expiration, or use-by-date will not be displayed.
For all products, we recommend handling per defined conditions as printed in our product literature and website product descriptions. We recommend that products should be routinely inspected by customers to ensure they perform as expected.
For products without retest or expiration dates, our standard warranty of 1 year from the date of shipment is applicable.
For more information, please refer to the Product Dating Information document: https://www.sigmaaldrich.com/deepweb/assets/sigmaaldrich/marketing/global/documents/449/386/product-dating-information-mk.pdf
おすすめの製品
アプリケーション
包装
トリアセチン(C2:0)
トリブチリン(C4:0)
トリカプロイン(C6:0)
トリカプリリン(C8:0)
トリカプリ(C10:0)が含まれます
関連製品
保管分類コード
10 - Combustible liquids
WGK
WGK 3
引火点(°F)
300.0 °F
引火点(℃)
148.9 °C
適用法令
試験研究用途を考慮した関連法令を主に挙げております。化学物質以外については、一部の情報のみ提供しています。 製品を安全かつ合法的に使用することは、使用者の義務です。最新情報により修正される場合があります。WEBの反映には時間を要することがあるため、適宜SDSをご参照ください。
Jan Code
17810-1AMP-S:
最新バージョンのいずれかを選択してください:
この製品を見ている人はこちらもチェック
-
How can I determine the shelf life / expiration / retest date of this product?
1 回答-
役に立ちましたか?
-
-
How is shipping temperature determined? And how is it related to the product storage temperature?
1 回答-
Products may be shipped at a different temperature than the recommended long-term storage temperature. If the product quality is sensitive to short-term exposure to conditions other than the recommended long-term storage, it will be shipped on wet or dry-ice. If the product quality is NOT affected by short-term exposure to conditions other than the recommended long-term storage, it will be shipped at ambient temperature. As shipping routes are configured for minimum transit times, shipping at ambient temperature helps control shipping costs for our customers. For more information, please refer to the Storage and Transport Conditions document: https://www.sigmaaldrich.com/deepweb/assets/sigmaaldrich/marketing/global/documents/316/622/storage-transport-conditions-mk.pdf
役に立ちましたか?
-
-
Is standard 17810 actually in the amount of 100 mg? Are standards weighed to the exact amount as indicated?
1 回答-
The standard 17810 is not actually in the amount of 100 mg. Both neat (pure) and solution standards are typically weighed or dispensed with approximately 10-15% extra product to allow for accurate measurement of the total amount indicated. Therefore, while it is indicated to have 100mg, there is an extra amount typically added during the weighing and packaging process
役に立ちましたか?
-
-
해당 제품을 50 mg/mL로 희석하여 사용하고자 합니다. 알맞은 용매가 있을까요?
1 回答-
This product is not tested for solubility. Lipids are not directly soluble in aqeuous solutions. Typically, strong non-polar solvents are used to dissolve these compounds. Hexane has been used in analytical testing of the individual triglyderides. In most liquid chromatography techniques the solvents utilized are acetone and/or acetonitrile. In gas chromatography the mixture is derivatized to methyl esters using hexane, ether, or toluene. Pyridine is also a suitable solvent prior to derivatization with MSTFA. During manufacturing, chloroform is commonly used.
Other suggested intermediate solvents include acetone, ethanol, and dimethylsulfoxide. Please see the link below to review additional information on lipids:
http://www.cyberlipid.org/役に立ちましたか?
-
-
こちらの製品(17810)のモル濃度と液量が知りたいです
1 回答-
This product is a neat or pure liquid that is sold by weight. Each 100 mg ampule is comprised of approximately 20% of each component:
Tributyrin, CAS 60-01-5, density 1.032 g/mL, MW 302.36
Tricaproin, CAS 621-70-5, density 0.98 g/mL, MW 386.52
Triacetin, CAS 102-76-1, density 1.16 g/mL, MW 218.20
Tricaprylin, CAS 538-23-8, density 0.956 g/mL, MW 470.68
Tricaprin CAS 621-71-6, powder, MW 554.84The exact volume is not reported, however, based on the densities of the components, a 100 mg package would have a volume of approximately 100 ul.