コンテンツへスキップ
Merck

B6420

Sigma-Aldrich

BES

BioXtra, ≥99.0% (titration)

別名:

N,N-ビス(2-ヒドロキシエチル)-2-アミノエタンスルホン酸, N,N-ビス(2-ヒドロキシエチル)タウリン

ログイン組織・契約価格を表示する


About This Item

実験式(ヒル表記法):
C6H15NO5S
CAS番号:
分子量:
213.25
Beilstein:
1781572
EC Number:
MDL番号:
UNSPSCコード:
12161700
PubChem Substance ID:
NACRES:
NA.25

製品種目

BioXtra

アッセイ

≥99.0% (titration)

フォーム

crystalline

不純物

≤0.0005% Phosphorus (P)
≤0.1% Insoluble matter

強熱残分

≤0.2%

pH

2.5-5.0 (25 °C, 213.3 g/L)

有効pH範囲

6.4-7.8

pKa (25 °C)

7.1

溶解性

H2O: 1 M, clear, colorless

微量陰イオン

chloride (Cl-): ≤0.05%
sulfate (SO42-): ≤0.05%

微量陽イオン

Al: ≤0.0005%
Ca: ≤0.0005%
Cu: ≤0.0005%
Fe: ≤0.0005%
K: ≤0.005%
Mg: ≤0.0005%
NH4+: ≤0.05%
Na: ≤0.005%
Pb: ≤0.001%
Zn: ≤0.0005%

Absorption

≤0.080 at 280 in H2O at 1 M
≤0.095 at 260 in H2O at 1 M

SMILES記法

OCCN(CCO)CCS(O)(=O)=O

InChI

1S/C6H15NO5S/c8-4-1-7(2-5-9)3-6-13(10,11)12/h8-9H,1-6H2,(H,10,11,12)

InChI Key

AJTVSSFTXWNIRG-UHFFFAOYSA-N

類似した製品をお探しですか? 訪問 製品比較ガイド

保管分類コード

11 - Combustible Solids

WGK

WGK 3

引火点(°F)

Not applicable

引火点(℃)

Not applicable

個人用保護具 (PPE)

dust mask type N95 (US), Eyeshields, Gloves


適用法令

試験研究用途を考慮した関連法令を主に挙げております。化学物質以外については、一部の情報のみ提供しています。 製品を安全かつ合法的に使用することは、使用者の義務です。最新情報により修正される場合があります。WEBの反映には時間を要することがあるため、適宜SDSをご参照ください。

Jan Code

B6420-RSAMPLE:
B6420-BULK:
B6420-BULK-PC:
B6420-100G:
B6420-25G:
B6420-VAR:


最新バージョンのいずれかを選択してください:

試験成績書(COA)

Lot/Batch Number

適切なバージョンが見つかりませんか。

特定のバージョンが必要な場合は、ロット番号またはバッチ番号で特定の証明書を検索できます。

以前この製品を購入いただいたことがある場合

文書ライブラリで、最近購入した製品の文書を検索できます。

文書ライブラリにアクセスする

Russell A Jensen et al.
The journal of physical chemistry letters, 6(15), 2933-2937 (2015-08-13)
Colloidal CdSe quantum dot (QD) core ensembles were photodimmed and allowed to recover in the dark using ambient thermal energy at a range of temperatures. Nonlinear thermal recovery is well described by a stretched exponential function, and further analysis yields
Kensuke Nishimiya et al.
Circulation journal : official journal of the Japanese Circulation Society, 79(6), 1323-1331 (2015-04-07)
Coronary adventitia harbors a wide variety of components, such as inflammatory cells and vasa vasorum (VV). Adventitial VV initiates the development of coronary artery diseases as an outside-in supply route of inflammation. We have recently demonstrated that drug-eluting stent implantation
Yingjie Zhang et al.
Nano letters, 15(7), 4657-4663 (2015-06-24)
Noncrystalline semiconductor materials often exhibit hysteresis in charge transport measurements whose mechanism is largely unknown. Here we study the dynamics of charge injection and transport in PbS quantum dot (QD) monolayers in a field effect transistor (FET). Using Kelvin probe
John A Ormiston et al.
EuroIntervention : journal of EuroPCR in collaboration with the Working Group on Interventional Cardiology of the European Society of Cardiology, 10(12), 1449-1455 (2014-11-26)
Stent fracture is important because it may cause adverse events. The interventional cardiologist needs independent data to aid stent selection. Stent designers need data to improve stent design. We used a repetitive bend test to compare durability and fracture for
Brian A Karolewski et al.
Human gene therapy, 14(14), 1287-1296 (2003-09-25)
A number of different transfection reagents have been used for lentiviral vector production. We directly compared transfection buffers, DNA purification methods, chemical facilitators, and DNA concentrations to optimize production. The use of N,N-bis (2-hydroxyethyl)-2-aminoethanesulfonic acid (BES), sodium butyrate, and one

ライフサイエンス、有機合成、材料科学、クロマトグラフィー、分析など、あらゆる分野の研究に経験のあるメンバーがおります。.

製品に関するお問い合わせはこちら(テクニカルサービス)