Passa al contenuto
Merck
Tutte le immagini(1)

Documenti fondamentali

57281-U

Supelco

SPME LC Fiber Probe, C18

df 45 μm(C18, pkg of 5 ea

Autenticatiper visualizzare i prezzi riservati alla tua organizzazione & contrattuali


About This Item

Codice UNSPSC:
41115724
NACRES:
NB.21

Materiali

metal alloy fiber
plain red hub

Misura ago

22 ga

Confezionamento

pkg of 5 ea

df

45 μm (C18)

tecniche

solid phase microextraction (SPME): suitable

Lungh. ago

25 mm (1 in.)

Gruppo funzionale matrice

C18 coating

applicazioni

food and beverages

Compatibilità

for use with solvent desorption

Tecnica di separazione

reversed phase

Descrizione generale

The SPME-LC fiber probes are intended as single-use devices for the extraction of small molecules out of a fluid followed by solvent desorption and LC analysis.

Scegli una delle versioni più recenti:

Certificati d'analisi (COA)

Lot/Batch Number

It looks like we've run into a problem, but you can still download Certificates of Analysis from our Documenti section.

Se ti serve aiuto, non esitare a contattarci Servizio Clienti

Possiedi già questo prodotto?

I documenti relativi ai prodotti acquistati recentemente sono disponibili nell’Archivio dei documenti.

Visita l’Archivio dei documenti

I clienti hanno visto anche

Slide 1 of 2

1 of 2

Florin Marcel Musteata et al.
Journal of pharmaceutical and biomedical analysis, 47(4-5), 907-912 (2008-05-13)
Pharmacokinetic (PK) studies in rats typically involve removal of serial blood samples following dosing. This research illustrates the development of a fast in vivo microextraction technique that has the potential to partly replace current sampling techniques based on blood draws
Barbara Bojko et al.
Analytica chimica acta, 803, 75-81 (2013-11-13)
Metabolomics and biomarkers discovery are an integral part of bioanalysis. However, untargeted tissue analysis remains as the bottleneck of such studies due to the invasiveness of sample collection, as well as the laborious and time-consuming sample preparation protocols. In the
In Vivo Sampling of Environmental Organic Contaminants in Fish by Solid-Phase Microextraction
Zhang, X., et al.
TrAC, Trends in Analytical Chemistry, 32, 31-39 (2012)
Barbara Bojko et al.
Analytica chimica acta, 750, 132-151 (2012-10-16)
Solid phase microextraction (SPME) has experienced rapid development and growth in number of application areas since its inception over 20 years ago. It has had a major impact on sampling and sample preparation practices in chemical analysis, bioanalysis, food and
Metabolic Profiling of Plasma from Cardiac Surgical Patients Concurrently Administered with Tranexamic Acid: DI-SPME?LC?MS Analysis
Bojko, B., et al.
Journal of Pharmaceutical Analysis, 4 (1), 6-13 (2014)

Articoli

Biocompatible SPME devices employ C18 bonded porous silica sorbent particles, in a binder which resists fouling by biological matrix components

Accurate protein binding affinities were measured using bioSPME more rapidly than membrane dialysis (RED) techniques. Binding affinities correlated to the reference values.

Contenuto correlato

A demonstration of the use of innovative BioSPME fibers for the selective extraction of drugs and polar metbolites from biological matrices.

Domande

Recensioni

Nessuna valutazione

Filtri attivi

Il team dei nostri ricercatori vanta grande esperienza in tutte le aree della ricerca quali Life Science, scienza dei materiali, sintesi chimica, cromatografia, discipline analitiche, ecc..

Contatta l'Assistenza Tecnica.