About This Item

Codice UNSPSC:
12161503
NACRES:
NA.84

533,00 €


Per informazioni sulla disponibilità, contatta il Servizio Clienti.

Richiedi un ordine bulk

impiego

sufficient for 200 colorimetric tests

Metodo di rivelazione

colorimetric

Malattie correlate

cancer

Temperatura di conservazione

2-8°C

Descrizione generale

ATPases and GTPases catalyze the decomposition of ATP or GTP into ADP or GDP and free phosphate. These enzymes play key roles in transport, signal transduction, protein biosynthesis, and cell differentiation.

Caratteristiche e vantaggi

Compatible with high-throughput handling systems.

Compatibilità

Suitable for the detection of ATPase and GTPase activity and for the screening of ATPase and GTPase inhibitors.

Principio

The ATPase/GTPase Activity Assay kit provides a simple and direct procedure for measuring ATPase/GTPase activity in a microplate format. This kit uses a single reagent formulation to accurately determine enzyme activity in 30 minutes at room temperature. The malachite green reagent forms a stable dark green color with free phosphate liberated by the enzymes resulting in a colorimetric product, measured at 620 nm (600-660 nm), proportional to the enzyme activity present One unit of activity is the amount of enzyme that catalyzes the production of 1 μmole of free phosphate per minute under the assay conditions.

Pittogrammi

Corrosion

Avvertenze

Warning

Indicazioni di pericolo

Consigli di prudenza

Classi di pericolo

Met. Corr. 1

Codice della classe di stoccaggio

8B - Non-combustible corrosive hazardous materials

Punto d’infiammabilità (°F)

Not applicable

Punto d’infiammabilità (°C)

Not applicable


Scegli una delle versioni più recenti:

Certificati d'analisi (COA)

Lot/Batch Number

Non trovi la versione di tuo interesse?

Se hai bisogno di una versione specifica, puoi cercare il certificato tramite il numero di lotto.

Possiedi già questo prodotto?

I documenti relativi ai prodotti acquistati recentemente sono disponibili nell’Archivio dei documenti.

Visita l’Archivio dei documenti

Meng-Yan Sun et al.
Oncology reports, 39(6), 2673-2680 (2018-04-06)
Regulator of G‑protein signaling 1 (RGS1) has been found to be a critical factor in melanoma and other malignancies. However, the mechanism involved in the RGS1‑mediated promotion of melanoma progression is not clear. We based our study on samples collected from
Shuhui Wang et al.
Protein & cell, 11(2), 124-137 (2019-11-24)
Type VII secretion systems (T7SSs) are found in many disease related bacteria including Mycobacterium tuberculosis (Mtb). ESX-1 [early secreted antigen 6 kilodaltons (ESAT-6) system 1] is one of the five subtypes (ESX-1~5) of T7SSs in Mtb, where it delivers virulence
Meifang Li et al.
International journal of biological sciences, 15(12), 2522-2537 (2019-11-23)
Despite remarkable advancements in our understanding of breast cancer, it remains the leading cause of cancer deaths in women. Distant recurrence and metastasis is the main reason for death due to breast cancer. It is well recognized that the GATA
Senyuan Cai et al.
Bioorganic & medicinal chemistry, 27(7), 1274-1282 (2019-02-23)
Filamenting temperature-sensitive mutant Z (FtsZ) is recognized as a promising target for new antibiotics development because of its high conservatism and pivotal role in the bacteria cell division. The aromatic heterocyclic scaffold of indole is known showing merit medical functions
Yupeng Zhao et al.
iScience, 23(9), 101494-101494 (2020-09-12)
Atlastin (ATL) is a class of dynamin-like GTPases shaping endoplasmic reticulum (ER) by mediating homotypic membrane fusion. Defect of ATLs leads to abnormal ER structure and hereditary spastic paraplegia (HSP), a neurodegenerative disease with progressive spasticity. How ATLs are regulated

Domande

1–6 di 6 domande  
  1. How can I determine the shelf life / expiration / retest date of this product?

    1 risposta
    1. If this product has an expiration or retest date, it will be shown on the Certificate of Analysis (COA, CofA). If there is no retest or expiration date listed on the product's COA, we do not have suitable stability data to determine a shelf life. For these products, the only date on the COA will be the release date; a retest, expiration, or use-by-date will not be displayed.
      For all products, we recommend handling per defined conditions as printed in our product literature and website product descriptions. We recommend that products should be routinely inspected by customers to ensure they perform as expected.
      For products without retest or expiration dates, our standard warranty of 1 year from the date of shipment is applicable.
      For more information, please refer to the Product Dating Information document: https://www.sigmaaldrich.com/deepweb/assets/sigmaaldrich/marketing/global/documents/449/386/product-dating-information-mk.pdf

      Utile?

  2. How is shipping temperature determined? And how is it related to the product storage temperature?

    1 risposta
    1. Products may be shipped at a different temperature than the recommended long-term storage temperature. If the product quality is sensitive to short-term exposure to conditions other than the recommended long-term storage, it will be shipped on wet or dry-ice. If the product quality is NOT affected by short-term exposure to conditions other than the recommended long-term storage, it will be shipped at ambient temperature. As shipping routes are configured for minimum transit times, shipping at ambient temperature helps control shipping costs for our customers. For more information, please refer to the Storage and Transport Conditions document: https://www.sigmaaldrich.com/deepweb/assets/sigmaaldrich/marketing/global/documents/316/622/storage-transport-conditions-mk.pdf

      Utile?

  3. Is the MAK113 ATPase/GTPase Activity Assay Kit compatible in both acidic and basic pH environments? Within what pH range is this assay compatible? I am attempting to measure the GTPase activity within a pH range of 5.5 - 8.0.

    1 risposta
    1. As per the guidance, the assay has been optimized with Assay Buffer at pH 7.5. It's important to note that the assay is pH dependent, and the enzymatic reaction is stopped by adding an acidic reagent. With the samples themselves expected to be largely neutralized by the assay buffer, they should be suitable within the pH range of 5.5 to 8. However, it is not advisable to prepare a different buffer to test the reaction under more acidic conditions. There is a possibility that conducting the reaction under more acidic conditions, like pH 5.5, might inhibit enzyme activity.

      Utile?

  4. Does malachite green react with phosphate molecules in which one oxygen is substituted by sulfur when using GTPgammaS instead of GTP to detect RAN GTPase activity? Additionally, could malachite green turn blue in reaction with other molecules besides phosphate?

    1 risposta
    1. Unfortunately, it has not been tested whether malachite green also reacts with phosphate molecules in which one oxygen is substituted with sulfur, and there is uncertainty about other molecules that could cause a blue color change. It is also possible that there might be contaminating free phosphate in the materials used for the assay. The datasheet for the kit contains instructions on how to check for any contaminating free phosphate.

      Utile?

  5. Would storage of the MAK113 ATPase/GTPase Activity Assay Kit at -20°C for 4 days affect its performance?

    1 risposta
    1. Based on available information, it is not expected that storage at -20°C would significantly affect the kit’s performance or shelf life.

      Utile?

  6. What is the detailed composition of Malachite Green Reagent (MAK 113A) in the ATPase/GTPase Activity Assay Kit (MAK113)?

    1 risposta
    1. A detailed composition of the reagent is not available as this is considered proprietary information.

      Utile?

Recensioni

Nessuna valutazione

Filtri attivi

Il team dei nostri ricercatori vanta grande esperienza in tutte le aree della ricerca quali Life Science, scienza dei materiali, sintesi chimica, cromatografia, discipline analitiche, ecc..

Contatta l'Assistenza Tecnica.