Passa al contenuto
Merck
Tutte le immagini(2)

Documenti

1.10004

Supelco

Iron Test Strips, colorimetric

greener alternative

3-500 mg/L (Fe²⁺), MQuant®

Sinonimo/i:

Iron chemical test strips

Autenticatiper visualizzare i prezzi riservati alla tua organizzazione & contrattuali


About This Item

Codice UNSPSC:
41116116
NACRES:
NA.24

product name

Iron Test, colorimetric, 3-500 mg/L (Fe2+), MQuant®

Descrizione

semi-quantitative

Livello qualitativo

Nome Commerciale

MQuant®

Analiti specifici

iron

Caratteristiche più verdi

Waste Prevention
Learn more about the Principles of Green Chemistry.

sustainability

Greener Alternative Product

Campo di misura

3-500 mg/L (Fe2+)

Metodo di rivelazione

colorimetric

Categoria alternativa più verde

Temperatura di conservazione

15-25°C

Descrizione generale

Method: Colorimetric, with test strips, 3 - 10 - 25 - 50 - 100 - 250 - 500 mg/L (Fe²+), MQuant®

The MQuant® test strips offer a very simple means of determining iron(II) in all aqueous media and on metal surfaces. They can thus be used to distinguish between ferrous and non-ferrous metals. Iron(II) ions react with 2,2′-bipyridine to form a red complex. The iron(II) concentration is measured semi-quantitatively by visual comparison of the reaction zone of the test strip with the fields of a color scale. For a determination of Fe(III) it is necessary to treat the sample with Ascorbic acid first, to reduce Fe(III) to Fe(II). The test strips are perfect for pre-testing a sample in an economic and quick way to estimate the iron concentration and a possible dilution factor prior to using a quantitative method such as a Reflectoquant® or Spectroquant® test.

We continue to demonstrate our commitment to our planet and a sustainable future by exploring ways to improve existing products in our portfolio. We have recently reviewed the current line of MQuant® test strips to identify key opportunities to minimize impact without compromising on the product performance.This product has benefited from:
  • Test strip with reduction
  • Recycled aluminum tube
  • Digital instruction leaflet
Learn more about the initiative: Small Changes to Test Strips for Big Impact.

Applicazioni


  • Detection and evaluation of susceptibility to antibiotics in non-hydrogen sulfide-producing antibiotic-resistant soil microbe: Pseudomonas guariconensis.: This study focuses on detecting and evaluating the antibiotic resistance of Pseudomonas guariconensis, a soil microbe, using various susceptibility tests, including iron assays to understand its resistance mechanisms (Selvakumar et al., 2024).

  • Genetic diversity and iron metabolism of Staphylococcus hominis isolates originating from bovine quarter milk, rectal feces, and teat apices.: The research explores the genetic diversity and iron metabolism pathways of Staphylococcus hominis isolates from different bovine sources, highlighting the role of iron assays in understanding bacterial physiology and resistance (Reydams et al., 2022).

  • Anemia Prevalence, Type, and Associated Risks in a Cohort of 5.0 Million Insured Patients in the United States by Level of Kidney Function.: This large-scale study investigates anemia prevalence and types across varying levels of kidney function, utilizing iron tests to evaluate iron deficiency and its impact on health outcomes (Farrington et al., 2023).

  • Influence of serum iron test results on the diagnosis of iron deficiency in children: a retrospective observational study.: This study examines how serum iron test results influence the diagnosis of iron deficiency in pediatric populations, emphasizing the importance of accurate iron testing in clinical diagnostics (Sezgin et al., 2021).

  • Validation of magnetic resonance relaxometry R2 value and cyst fluid iron level for diagnosis of ovarian endometrioma.: The study validates the use of magnetic resonance relaxometry and iron level measurements in cyst fluid for diagnosing ovarian endometrioma, demonstrating the application of iron tests in medical imaging and diagnostics (Imanaka et al., 2021).

Linkage

Replaces: 10004-1; 10004

Note legali

MQUANT is a registered trademark of Merck KGaA, Darmstadt, Germany
REFLECTOQUANT is a registered trademark of Merck KGaA, Darmstadt, Germany
SPECTROQUANT is a registered trademark of Merck KGaA, Darmstadt, Germany

Codice della classe di stoccaggio

11 - Combustible Solids

Classe di pericolosità dell'acqua (WGK)

WGK 2


Certificati d'analisi (COA)

Cerca il Certificati d'analisi (COA) digitando il numero di lotto/batch corrispondente. I numeri di lotto o di batch sono stampati sull'etichetta dei prodotti dopo la parola ‘Lotto’ o ‘Batch’.

Possiedi già questo prodotto?

I documenti relativi ai prodotti acquistati recentemente sono disponibili nell’Archivio dei documenti.

Visita l’Archivio dei documenti

I clienti hanno visto anche

Slide 1 of 5

1 of 5

Cobalt Test colorimetric, 10-1000 mg/L (Co2+), MQuant®

Supelco

1.10002

Cobalt Test

Zinc Test colorimetric, 0-50 mg/L (Zn), MQuant®

Supelco

1.17953

Zinc Test

Nickel Test colorimetric, 10-500 mg/L (Ni), MQuant®

Supelco

1.10006

Nickel Test

Iron Stain

Sigma-Aldrich

HT20

Iron Stain

Il team dei nostri ricercatori vanta grande esperienza in tutte le aree della ricerca quali Life Science, scienza dei materiali, sintesi chimica, cromatografia, discipline analitiche, ecc..

Contatta l'Assistenza Tecnica.