Documenti

1.09142

Supelco

Idrossido di sodio

c(NaOH) = 0.02 mol/l (0.02 N), reag. USP, ready-to-use volumetric solution for titration, Titriplex®

Autenticatiper visualizzare i prezzi riservati alla tua organizzazione & contrattuali


About This Item

Formula condensata:
NaOH
Numero CAS:
Peso molecolare:
40.00
Numero MDL:
Codice UNSPSC:
12352305
NACRES:
NA.21

product name

Idrossido di sodio, c(NaOH) = 0.02 mol/l (0.02 N), Titripur®, reag. USP

agenzia

reag. USP

Livello qualitativo

Tensione di vapore

3 mmHg ( 37 °C)

Nome Commerciale

Titripur®

Forma fisica

liquid

Qualità

Analyzed in our ISO 17025 accredited QC lab

Impiego in reazioni chimiche

reaction type: Acid-base reactions

Concentrazione

0.02 M

tecniche

titration: suitable

pH

12.5 (20 °C in H2O)

Densità

1.00 g/cm3 at 20 °C

Temperatura di conservazione

15-25°C

Stringa SMILE

[OH-].[Na+]

InChI

1S/Na.H2O/h;1H2/q+1;/p-1
HEMHJVSKTPXQMS-UHFFFAOYSA-M

Cerchi prodotti simili? Visita Guida al confronto tra prodotti

Applicazioni


  • Ozone-activated Lignocellulose Films: Discusses the preparation of ozone-activated lignocellulose films blended with chitosan using sodium hydroxide solution, aimed at producing biodegradable and edible films for food packaging, emphasizing sustainability and environmental safety (Ebrahimi SS, Hamzeh Y, et al., 2024).

  • Cellulose Dissolution in ZnO/NaOH/Water: Details the study of cellulose dissolution in a ZnO/NaOH/water solvent solution using molecular dynamics simulation, demonstrating the temperature-dependent effects which are crucial for developing new materials in textile and pharmaceutical industries (Bourassi L, El Mrani M, et al., 2024).

  • Recycling of Geopolymer Concrete: Utilizes sodium hydroxide solution in the recycling of metakaolin/slag-based geopolymer concrete under various strength levels and freeze-thaw conditions, contributing to sustainable construction practices (Liu M, Liu H, et al., 2024).

  • Sensitivity-Enhanced Detection of NH3: Reports on the development of sensitivity-enhanced, room-temperature NH3 detection using alkalized Ti3C2Tx MXene, where sodium hydroxide solution plays a critical role in modifying the electroconductive properties for sensor applications (Tan Y, Xu J, et al., 2024).

Caratteristiche e vantaggi

Accreditation:
This volumetric solution is analyzed by our calibration laboratory D-K-15185-01-00 which is accredited according to DIN EN ISO/IEC 17025 for analysis of amount-of-substance concentrations in volumetric solutions by DAkkS (Deutsche Akkreditierungsstelle - German National Accreditation Body). The accreditation certificate can be found at www.sigmaaldrich.com/ISO17025.

Confezionamento

SKU-pack size numbers ending with a "3" are SmartChemicals with an RFID tag on the label for seamless data transfer to the instrument, e.g. xxxxxx1003 or xxxxxxx 4003. More information on www.sigmaaldrich.com/SmartChemicals

Risultati analitici

Form liquid
Amount-of-substance concentration 0.01990 - 0.02010 mol/L
Measurement uncertainty ± 0.00006 mol/L
Traceability NIST SRM

The concentration is determined by volumetric titration and refers to 20°C.
The amount-of-substance concentration of this volumetric solution is determined with standardized hydrochloric acid solution (article number 1.09060). The hydrochloric acid solution is standardized and traceable to a primary standard reference material (SRM) from the National Institute of Standards and Technology, Gaithersburg, USA (NIST SRM 723 Tris(hydroxymethyl)aminomethane) by means of volumetric standard Tris(hydroxymethyl)aminomethane (article number 1.02408), certified reference material according to ISO 17034, analyzed by our accredited calibration laboratory of Merck KGaA, Darmstadt, Germany according to DIN EN ISO/IEC 17025. The uncertainty is expressed as expanded measurement uncertainty with a coverage factor k=2 covering a confidence level of 95%.

Note: The titer is a correction factor to correct for variations of the volumetric solution, the titration equipment, the temperature and other laboratory conditions. For correct titration results it is recommended to determine a titer with the laboratory specific equipment and under laboratory specific conditions directly after opening a new bottle and at regular time intervals.

Note legali

Titripur is a registered trademark of Merck KGaA, Darmstadt, Germany

Codice della classe di stoccaggio

12 - Non Combustible Liquids

Classe di pericolosità dell'acqua (WGK)

nwg


Certificati d'analisi (COA)

Cerca il Certificati d'analisi (COA) digitando il numero di lotto/batch corrispondente. I numeri di lotto o di batch sono stampati sull'etichetta dei prodotti dopo la parola ‘Lotto’ o ‘Batch’.

Possiedi già questo prodotto?

I documenti relativi ai prodotti acquistati recentemente sono disponibili nell’Archivio dei documenti.

Visita l’Archivio dei documenti

I clienti hanno visto anche

Slide 1 of 4

1 of 4

Il team dei nostri ricercatori vanta grande esperienza in tutte le aree della ricerca quali Life Science, scienza dei materiali, sintesi chimica, cromatografia, discipline analitiche, ecc..

Contatta l'Assistenza Tecnica.