跳转至内容
Merck
  • High-throughput automatic flow method for determination of trace concentrations of aluminum in dialysis concentrate solutions using salicylaldehyde picolinoylhydrazone as a turn-on fluorescent probe.

High-throughput automatic flow method for determination of trace concentrations of aluminum in dialysis concentrate solutions using salicylaldehyde picolinoylhydrazone as a turn-on fluorescent probe.

Talanta (2014-12-02)
Arnau Garau, Miquel Oliver, María Rosende, Manuel P Mánuel-Vez, Manuel Miró
摘要

A simple and expedient flow-based assembly capitalizing on programmable flow is herein proposed for reliable determination of trace level concentrations of aluminum as a potential contaminant in dialysis concentrate solutions without any prior sample clean-up/preconcentration procedure. Using salicylaldehyde picolinoylhydrazone in weakly acidic media as a turn-on fluorescent probe, the manifold is devised to handle three samples concurrently in stopped-flow reaction mode for simultaneous improvement of the analytical sensitivity and sample throughput. Analytical parameters influencing the sensitivity and repeatability of the assays, namely, probe concentration, reaction temperature and reaction time were investigated using a multivariate optimization protocol composed of a full factorial screening design followed by a Doehlert matrix model. The analysis of the Pareto chart and surface response revealed that the reaction time and amount of fluorescent probe were critical parameters for reliable assays of aluminum at the low ng mL(-1) level. Under the optimized chemical and physical variables, a detection limit of 1.1ngmL(-1) Al(III) at the 3s(blank) level, relative standard deviations better than 1.0%, a dynamic linear range of 5.0-80 ng mL(-1) and a sample throughput up to 25 h(-1) were obtained with no need for either sample preconcentration or the use of organized supramolecular systems. Demonstrated with the analysis of hemodialysis and peritoneal concentrate solutions, and dialysis waters, the flow-through method copes with the requirements of regulatory bodies (e.g., European Pharmacopeia) for quality control of aluminum in high salinity containing dialysis concentrates.

材料
货号
品牌
产品描述

Sigma-Aldrich
乙酸, glacial, ACS reagent, ≥99.7%
Sigma-Aldrich
乙酸, glacial, ReagentPlus®, ≥99%
Sigma-Aldrich
乙酸, glacial, ≥99.99% trace metals basis
Sigma-Aldrich
乙酸 溶液, suitable for HPLC
Sigma-Aldrich
乙酸, glacial, puriss., meets analytical specification of Ph. Eur., BP, USP, FCC, 99.8-100.5%
Sigma-Aldrich
乙酸, glacial, puriss. p.a., ACS reagent, reag. ISO, reag. Ph. Eur., ≥99.8%
Sigma-Aldrich
肼 溶液, 35 wt. % in H2O
Sigma-Aldrich
乙酸, for luminescence, BioUltra, ≥99.5% (GC)
USP
冰醋酸, United States Pharmacopeia (USP) Reference Standard
Sigma-Aldrich
乙酸, ≥99.5%, FCC, FG
Sigma-Aldrich
乙酸, natural, ≥99.5%, FG
Sigma-Aldrich
5α-雄甾烷-17β-醇-3-酮, ≥97.5%
Sigma-Aldrich
肼, anhydrous, 98%
Sigma-Aldrich
乙酸, glacial, puriss., 99-100%
Sigma-Aldrich
肼 溶液, 1.0 M in THF
Sigma-Aldrich
乙酸, JIS special grade, ≥99.7%
Sigma-Aldrich
乙酸, ≥99.7%
Sigma-Aldrich
肼 溶液, 1.0 M in ethanol
Sigma-Aldrich
乙酸, SAJ first grade, ≥99.0%
Sigma-Aldrich
乙酸 溶液, 1 M, 1 N
Sigma-Aldrich
肼 溶液, 1 M in acetonitrile
Sigma-Aldrich
2-吡啶甲酸乙酯, 99%
Sigma-Aldrich
乙酸, ≥99.7%
Sigma-Aldrich
乙酸-12C2, 99.9 atom % 12C
Supelco
5α-雄甾烷-17β-醇-3-酮, VETRANAL®, analytical standard
Millipore
Bifido 选择性添加剂 B, suitable for microbiology
Sigma-Aldrich
乙酸, 99.5-100.0%
Sigma-Aldrich
乙酸, ≥99.7%, suitable for amino acid analysis