推荐产品
生物来源
synthetic
蒸汽压
5.6 mmHg ( 100 °C)
方案
≥97%
折射率
n20/D 1.514 (lit.)
沸点
256 °C/764 mmHg (lit.)
mp
18 °C (lit.)
密度
0.962 g/mL at 25 °C (lit.)
应用
flavors and fragrances
SMILES字符串
CC(C)c1cccc(C(C)C)c1O
InChI
1S/C12H18O/c1-8(2)10-6-5-7-11(9(3)4)12(10)13/h5-9,13H,1-4H3
InChI key
OLBCVFGFOZPWHH-UHFFFAOYSA-N
基因信息
human ... CYP1A2(1544) , GABRA1(2554)
rat ... Gabra2(29706)
正在寻找类似产品? 访问 产品对比指南
警示用语:
Warning
危险分类
Acute Tox. 4 Oral - Eye Irrit. 2 - Skin Irrit. 2 - STOT SE 3
靶器官
Respiratory system
储存分类代码
10 - Combustible liquids
WGK
WGK 3
闪点(°F)
235.4 °F - closed cup
闪点(°C)
113 °C - closed cup
个人防护装备
Eyeshields, Faceshields, Gloves, type ABEK (EN14387) respirator filter
其他客户在看
Annette P N Kutter et al.
Anesthesia and analgesia, 121(1), 99-107 (2015-03-06)
In critically ill patients with significant pulmonary hypertension (PH), close perioperative cardiovascular monitoring is mandatory, considering the increased morbidity and mortality in this patient group. Although the pulmonary artery catheter is still the standard for the diagnosis of PH, its
Michael Schwarzl et al.
American journal of physiology. Heart and circulatory physiology, 309(9), H1407-H1418 (2015-09-06)
Heart failure with preserved ejection fraction (HFPEF) evolves with the accumulation of risk factors. Relevant animal models to identify potential therapeutic targets and to test novel therapies for HFPEF are missing. We induced hypertension and hyperlipidemia in landrace pigs (n
Philippe E Dubois et al.
European journal of anaesthesiology, 31(8), 404-410 (2013-07-26)
Disturbances in the thumb's movement interfere with the functioning of acceleromyography in many clinical settings. The short and light (SL) train-of-four (TOF)-Tube is a new version of a rigid tubular device that was designed to protect the thumb from external
Kim van Loon et al.
Anesthesia and analgesia, 119(1), 49-55 (2014-05-20)
Propofol, a short-acting hypnotic drug, is increasingly administered by a diverse group of specialists (e.g., cardiologists, gastroenterologists) during diagnostic and therapeutic procedures. Standard monitoring during sedation comprises continuous pulse oximetry with visual assessment of the patient's breathing pattern. Because undetected
Felix Schlegel et al.
NeuroImage, 116, 40-49 (2015-05-17)
In recent years, the number of functional MRI (fMRI) studies in mice has been rapidly increasing. Technological improvements provide the sensitivity required to match the high demands on spatial and temporal resolution and to analyze fast and small signal components
我们的科学家团队拥有各种研究领域经验,包括生命科学、材料科学、化学合成、色谱、分析及许多其他领域.
联系客户支持