H0290

Sigma-Aldrich

Hartman′s Fixative

histological tissue fixative

Synonyme(s) :

Davidson′s Fixative

Se connecterpour consulter vos tarifs contractuels et ceux de votre entreprise/organisme


About This Item

Code UNSPSC :
12171500
Nomenclature NACRES :
NA.47

Niveau de qualité

Forme

liquid

Application(s)

hematology
histology

Température de stockage

room temp

Description générale

Hartman′s fixative, which is also known as Davidson′s Fixative, contains acetic acid, alcohol, and formalin. It is widely used for the preservation of eye, bone marrow, breast, testis, and other tissues for histologic examination.

Application

An overnight fixative used for the visualization of lymph nodes in radical dissection specimens. It is helpful in visualizing both both breast and colon specimens by turning lymph nodes white. Moore and Barr used a version of Hartman′s fixative for fixing skin biopsy specimens for study of fine nuclear details. Rat testes for immunohistochemical and morphological comparison were fixed using conventional and modified Hartman′s fixative for 24 hours, while eyes and testes for other analyses were fixed for 48 hours.

Mention d'avertissement

Danger

Classification des risques

Acute Tox. 3 Inhalation - Acute Tox. 4 Dermal - Acute Tox. 4 Oral - Carc. 1B - Eye Dam. 1 - Flam. Liq. 3 - Muta. 2 - Skin Corr. 1 - Skin Sens. 1 - STOT SE 3

Organes cibles

Central nervous system, Respiratory system

Code de la classe de stockage

3 - Flammable liquids

Classe de danger pour l'eau (WGK)

WGK 3

Point d'éclair (°F)

75.2 °F

Point d'éclair (°C)

24 °C


Certificats d'analyse (COA)

Recherchez un Certificats d'analyse (COA) en saisissant le numéro de lot du produit. Les numéros de lot figurent sur l'étiquette du produit après les mots "Lot" ou "Batch".

Déjà en possession de ce produit ?

Retrouvez la documentation relative aux produits que vous avez récemment achetés dans la Bibliothèque de documents.

Consulter la Bibliothèque de documents

John R Latendresse et al.
Toxicologic pathology, 30(4), 524-533 (2002-08-22)
Most recent revisions of regulatory guidelines for testing effects of chemicals on reproduction recommend Bouin's fluid (BF) or a "comparable fixative" instead of formalin to preserve the morphologic detail of testes for histopathological evaluation. However, picric acid in BF is
Fixation of testes and eyes using a modified Davidson's fluid: comparison with Bouin's fluid and conventional Davidson's fluid.
Latendresse J R, et al.
Toxicologic Pathology, 30(4), 524-533 (2002)
G J Nuovo et al.
The American journal of pathology, 134(4), 837-842 (1989-04-01)
In situ hybridization is used commonly for detection of human papillomavirus (HPV) DNA. There is little information, however, on whether the detection of HPV DNA by in situ hybridization can be affected by the way in which the tissue is
The sex chromatin in human malignant tissues.
K L MOORE et al.
British journal of cancer, 11(3), 384-390 (1957-09-01)
Dan Wang et al.
Biology of reproduction, 102(5), 1033-1044 (2020-02-11)
Fertilization is one of the fundamental biological processes, but so far, we still do not have a full understanding of the underlying molecular mechanism. We have identified a human acrosome protein, LY6/PLAUR domain containing 4 (LYPD4), expressed specifically in human

Contenu apparenté

Three-dimensional (3D) printing of biological tissue is rapidly becoming an integral part of tissue engineering.

Three-dimensional (3D) printing of biological tissue is rapidly becoming an integral part of tissue engineering.

Three-dimensional (3D) printing of biological tissue is rapidly becoming an integral part of tissue engineering.

Three-dimensional (3D) printing of biological tissue is rapidly becoming an integral part of tissue engineering.

Notre équipe de scientifiques dispose d'une expérience dans tous les secteurs de la recherche, notamment en sciences de la vie, science des matériaux, synthèse chimique, chromatographie, analyse et dans de nombreux autres domaines..

Contacter notre Service technique