Accéder au contenu
Merck
Toutes les photos(1)

Documents

PHR1422

Supelco

Atorvastatin Calcium

Pharmaceutical Secondary Standard; Certified Reference Material

Synonyme(s) :

Atorvastatin hemicalcium salt sesquihydrate, 1H-Pyrrole-1-heptanoic acid, [R-(R*,R*)]-2-(4-flurophenyl)-β,δ-dihydroxy-5-(1-methylethyl)-3-phenyl-4-[(phenylamino)carbonyl], calcium salt (2:1)

Se connecterpour consulter vos tarifs contractuels et ceux de votre entreprise/organisme


About This Item

Formule empirique (notation de Hill):
C66H68CaF2N4O10 · 3H2O
Numéro CAS:
Poids moléculaire :
1209.39
Code UNSPSC :
41116107
Nomenclature NACRES :
NA.24

Qualité

certified reference material
pharmaceutical secondary standard

Niveau de qualité

Agence

traceable to Ph. Eur. Y0001327
traceable to USP 1044516

Famille d'API

atorvastatin

CofA (certificat d'analyse)

current certificate can be downloaded

Technique(s)

HPLC: suitable
gas chromatography (GC): suitable

Application(s)

pharmaceutical (small molecule)

Format

neat

Température de stockage

2-30°C

InChI

1S/2C33H35FN2O5.Ca.3H2O/c2*1-21(2)31-30(33(41)35-25-11-7-4-8-12-25)29(22-9-5-3-6-10-22)32(23-13-15-24(34)16-14-23)36(31)18-17-26(37)19-27(38)20-28(39)40;;;;/h2*3-16,21,26-27,37-38H,17-20H2,1-2H3,(H,35,41)(H,39,40);;3*1H2/q;;+2;;;/p-2/t2*26-,27-;;;;/m11..../s1

Clé InChI

SHZPNDRIDUBNMH-NIJVSVLQSA-L

Vous recherchez des produits similaires ? Visite Guide de comparaison des produits

Description générale

Atorvastatin Calcium is a synthetic cholesterol lowering agent, which acts as an inhibitor of 3-hydroxy-3-methyl glutaryl coenzyme A reductase. It is widely used in combination with amlodipine besylate as a medication in the treatment of vasospastic angina, hypertension, chronic stable angina and primary dysbetalipoproteinemia.
Pharmaceutical secondary standards for application in quality control, provide pharma laboratories and manufacturers with a convenient and cost-effective alternative to the preparation of in-house working standards.

Application

Azathioprine may be used as a pharmaceutical reference standard for the quantification of the analyte in pharmaceutical formulations using reversed-phase high-performance liquid chromatography (RP-HPLC) and spectrophotometric techniques.
These Secondary Standards are qualified as Certified Reference Materials. These are suitable for use in several analytical applications including but not limited to pharma release testing, pharma method development for qualitative and quantitative analyses, food and beverage quality control testing, and other calibration requirements.

Remarque sur l'analyse

These secondary standards offer multi-traceability to the USP, EP and BP primary standards, where they are available.

Autres remarques

This Certified Reference Material (CRM) is produced and certified in accordance with ISO 17034 and ISO/IEC 17025. All information regarding the use of this CRM can be found on the certificate of analysis.

Note de bas de page

To see an example of a Certificate of Analysis for this material enter LRAC0148 in the slot below. This is an example certificate only and may not be the lot that you receive.

Analyte

Description

    Atorvastatin hemicalcium salt sesquihydrate

Produit(s) apparenté(s)

Réf. du produit
Description
Tarif

Pictogrammes

Health hazard

Mention d'avertissement

Danger

Mentions de danger

Classification des risques

Carc. 2 - Repr. 1B

Code de la classe de stockage

6.1C - Combustible acute toxic Cat.3 / toxic compounds or compounds which causing chronic effects

Classe de danger pour l'eau (WGK)

WGK 3

Point d'éclair (°F)

Not applicable

Point d'éclair (°C)

Not applicable


Choose from one of the most recent versions:

Certificats d'analyse (COA)

Lot/Batch Number

Don't see the Right Version?

If you require a particular version, you can look up a specific certificate by the Lot or Batch number.

Déjà en possession de ce produit ?

Retrouvez la documentation relative aux produits que vous avez récemment achetés dans la Bibliothèque de documents.

Consulter la Bibliothèque de documents

Les clients ont également consulté

Slide 1 of 2

1 of 2

Simultaneous Spectrophotometric Determination of Atorvastatin Calcium and Ezetimibe in Tablet Dosage Form
GRB, et al.
International Journal of ChemTech Research, 1(2), 233-236 (2009)
Stability indicating RP-HPLC estimation of atorvastatin calcium and amlodipine besylate in pharmaceutical formulations
Shah AD, et al.
Indian Journal of Pharmaceutical Sciences, 70(6), 754-754 (2008)
Xiao-ling Li et al.
International immunopharmacology, 23(2), 546-549 (2014-12-03)
This study aimed to investigate the efficacy of combined atorvastatin calcium and methylprednisolone for the treatment of multiple sclerosis relapse. Patients with multiple sclerosis (MS) at the relapse phase were randomized to receive either combined treatment of atorvastatin calcium and
Peter Norsk et al.
The Journal of physiology, 593(3), 573-584 (2015-03-17)
Weightlessness in space induces initially an increase in stroke volume and cardiac output, accompanied by unchanged or slightly reduced blood pressure.It is unclear whether these changes persist throughout months of flight.Here, we show that cardiac output and stroke volume increase
Yuka Keyamura et al.
PloS one, 9(5), e96929-e96929 (2014-05-09)
Lowering the blood concentration of low-density lipoprotein (LDL) cholesterol is the primary strategy employed in treating atherosclerotic disorders; however, most commonly prescribed statins prevent cardiovascular events in just 30% to 40% of treated patients. Therefore, additional treatment is required for

Notre équipe de scientifiques dispose d'une expérience dans tous les secteurs de la recherche, notamment en sciences de la vie, science des matériaux, synthèse chimique, chromatographie, analyse et dans de nombreux autres domaines..

Contacter notre Service technique