Sigma-Aldrich

Nortriptylin -hydrochlorid

≥98% (HPLC), powder

Synonym(e):

3-(10,11-Dihydro-5H-dibenzo[a,d]cyclohepten-5-yliden)-N-methyl-1-propanamin -hydrochlorid, Desmethylamitriptylin -hydrochlorid

Anmeldenzur Ansicht organisationsspezifischer und vertraglich vereinbarter Preise

Größe auswählen

10 G
117,00 €

117,00 €


Versandbereit am07. April 2025Details



Größe auswählen

Ansicht ändern
10 G
117,00 €

About This Item

Empirische Formel (Hill-System):
C19H21N · HCl
CAS-Nummer:
Molekulargewicht:
299.84
EG-Nummer:
MDL-Nummer:
UNSPSC-Code:
41116107
PubChem Substanz-ID:
NACRES:
NA.77

117,00 €


Versandbereit am07. April 2025Details


Assay

≥98% (HPLC)

Form

powder

Farbe

white to off-white

Löslichkeit

ethanol: 100 mg/mL
H2O: soluble

Ersteller

Eli Lilly

SMILES String

Cl.CNCC\C=C1\c2ccccc2CCc3ccccc13

InChI

1S/C19H21N.ClH/c1-20-14-6-11-19-17-9-4-2-7-15(17)12-13-16-8-3-5-10-18(16)19;/h2-5,7-11,20H,6,12-14H2,1H3;1H

InChIKey

SHAYBENGXDALFF-UHFFFAOYSA-N

Suchen Sie nach ähnlichen Produkten? Aufrufen Leitfaden zum Produktvergleich

Biochem./physiol. Wirkung

Tricyclic antidepressant that is a more potent inhibitor of the norepinephrine transporter (Ki = 3.4 nM) than the serotonin transporter (Ki = 161 nM). 5-HT2 serotonin receptor antagonist.

Leistungsmerkmale und Vorteile

This compound is featured on the Biogenic Amine Transporters page of the Handbook of Receptor Classification and Signal Transduction. To browse other handbook pages, click here.
This compound was developed by Eli Lilly. To browse the list of other pharma-developed compounds and Approved Drugs/Drug Candidates, click here.

Piktogramme

Exclamation mark

Signalwort

Warning

H-Sätze

Gefahreneinstufungen

Acute Tox. 4 Oral

Lagerklassenschlüssel

11 - Combustible Solids

WGK

WGK 3

Flammpunkt (°F)

Not applicable

Flammpunkt (°C)

Not applicable

Persönliche Schutzausrüstung

dust mask type N95 (US), Eyeshields, Faceshields, Gloves


Hier finden Sie alle aktuellen Versionen:

Analysenzertifikate (COA)

Lot/Batch Number

Die passende Version wird nicht angezeigt?

Wenn Sie eine bestimmte Version benötigen, können Sie anhand der Lot- oder Chargennummer nach einem spezifischen Zertifikat suchen.

Besitzen Sie dieses Produkt bereits?

In der Dokumentenbibliothek finden Sie die Dokumentation zu den Produkten, die Sie kürzlich erworben haben.

Die Dokumentenbibliothek aufrufen

Rudolf Uher et al.
Depression and anxiety, 29(12), 1043-1049 (2012-08-31)
It has been suggested that clinician-rated scales and self-report questionnaires may be interchangeable in the measurement of depression severity, but it has not been tested whether clinically significant information is lost when assessment is restricted to either clinician-rated or self-report
Fabrice Gritti et al.
Journal of chromatography. A, 1282, 58-71 (2013-02-21)
The adsorption behaviors of a neutral (caffeine) and a positively charged compound (nortriptylinium) are investigated on two RPLC/hybrid stationary phases, eluted with a low ionic strength buffer (phosphate buffer, W(S)pH 2.63, I=10mM). The first phase, bridge ethylene hybrid (BEH), is
Luis Enrique Chaparro et al.
The Cochrane database of systematic reviews, 7(7), CD008943-CD008943 (2012-07-13)
Pharmacotherapy remains an important modality for the treatment of neuropathic pain. However, as monotherapy current drugs are associated with limited efficacy and dose-related side effects. Combining two or more different drugs may improve analgesic efficacy and, in some situations, reduce
Aravind Penmatsa et al.
Nature, 503(7474), 85-90 (2013-09-17)
Antidepressants targeting Na(+)/Cl(-)-coupled neurotransmitter uptake define a key therapeutic strategy to treat clinical depression and neuropathic pain. However, identifying the molecular interactions that underlie the pharmacological activity of these transport inhibitors, and thus the mechanism by which the inhibitors lead
Matthew T Olson et al.
Clinical chemistry, 59(6), 920-927 (2013-02-22)
The addition of a calibration curve with every run is both time-consuming and expensive for clinical mass spectrometry assays. We present alternative calibration strategies that eliminate the need for a calibration curve except as required by laboratory regulations. We measured