Direkt zum Inhalt
Merck

PHR1219

Supelco

Aceton

Pharmaceutical Secondary Standard; Certified Reference Material

Anmeldenzur Ansicht organisationsspezifischer und vertraglich vereinbarter Preise

Größe auswählen

3 X 1.5 ML
91,80 €

91,80 €


Versandbereit am14. April 2025Details


Bulk-Bestellung anfordern

Größe auswählen

Ansicht ändern
3 X 1.5 ML
91,80 €

About This Item

Lineare Formel:
CH3COCH3
CAS-Nummer:
Molekulargewicht:
58.08
Beilstein:
635680
EG-Nummer:
MDL-Nummer:
UNSPSC-Code:
41116107
PubChem Substanz-ID:
NACRES:
NA.24

91,80 €


Versandbereit am14. April 2025Details


Bulk-Bestellung anfordern

Qualität

certified reference material
pharmaceutical secondary standard

Qualitätsniveau

Agentur

traceable to USP 1006801

Dampfdichte

2 (vs air)

Dampfdruck

184 mmHg ( 20 °C)

Form

liquid

Analysenzertifikat (CofA)

current certificate can be downloaded

Expl.-Gr.

13.2 %

Methode(n)

HPLC: suitable
gas chromatography (GC): suitable

Brechungsindex

n20/D 1.359 (lit.)

bp

56 °C/760 mmHg (lit.)

mp (Schmelzpunkt)

−94 °C (lit.)

Dichte

0.791 g/mL at 25 °C (lit.)

Anwendung(en)

pharmaceutical (small molecule)

Format

neat

Lagertemp.

2-30°C

SMILES String

CC(C)=O

InChI

1S/C3H6O/c1-3(2)4/h1-2H3

InChIKey

CSCPPACGZOOCGX-UHFFFAOYSA-N

Suchen Sie nach ähnlichen Produkten? Aufrufen Leitfaden zum Produktvergleich

Allgemeine Beschreibung

Pharmaceutical secondary standards for application in quality control provide pharma laboratories and manufacturers with a convenient and cost-effective alternative to the preparation of in-house working standards. Acetone is an organic compound and in contrast to petroleum based hexane, it is a biorenewable solvent obtained via fermentation. It is generally used as a solvent for many gums, resins, and in the production of plastics.

Anwendung

Die Lumineszenz-Intensität von Aceton ist abhängig von den Komponenten in der Lösung. Die Absorption von UV-Licht durch Aceton führt zur Photolyse und der Bildung von Radikalen .
These Secondary Standards are qualified as Certified Reference Materials. These are suitable for use in several analytical applications including but not limited to pharma release testing, pharma method development for qualitative and quantitative analyses, food and beverage quality control testing, and other calibration requirements.

Hinweis zur Analyse

These secondary standards offer multi-traceability to the USP, EP (PhEur) and BP primary standards, where they are available.

Sonstige Hinweise

This Certified Reference Material (CRM) is produced and certified in accordance with ISO 17034 and ISO/IEC 17025. All information regarding the use of this CRM can be found on the certificate of analysis.

Fußnote

To see an example of a Certificate of Analysis for this material enter LRAB5525 in the slot below. This is an example certificate only and may not be the lot that you receive.

Empfohlene Produkte

Find a digital Reference Material for this product available on our online platform ChemisTwin® for NMR. You can use this digital equivalent on ChemisTwin® for your sample identity confirmation and compound quantification (with digital external standard). An NMR spectrum of this substance can be viewed and an online comparison against your sample can be performed with a few mouseclicks. Learn more here and start your free trial.

Anwendung

Produkt-Nr.
Beschreibung
Preisangaben

Piktogramme

FlameExclamation mark

Signalwort

Danger

Gefahreneinstufungen

Eye Irrit. 2 - Flam. Liq. 2 - STOT SE 3

Zielorgane

Central nervous system

Zusätzliche Gefahrenhinweise

Lagerklassenschlüssel

3 - Flammable liquids

WGK

WGK 1

Flammpunkt (°F)

1.4 °F - closed cup

Flammpunkt (°C)

-17.0 °C - closed cup


Hier finden Sie alle aktuellen Versionen:

Analysenzertifikate (COA)

Lot/Batch Number

It looks like we've run into a problem, but you can still download Certificates of Analysis from our Dokumente section.

Wenn Sie Hilfe benötigen, wenden Sie sich bitte an Kundensupport

Besitzen Sie dieses Produkt bereits?

In der Dokumentenbibliothek finden Sie die Dokumentation zu den Produkten, die Sie kürzlich erworben haben.

Die Dokumentenbibliothek aufrufen

Juan A López-Ráez et al.
Plant science : an international journal of experimental plant biology, 230, 59-69 (2014-12-07)
Apocarotenoids are a class of compounds that play important roles in nature. In recent years, a prominent role for these compounds in arbuscular mycorrhizal (AM) symbiosis has been shown. They are derived from carotenoids by the action of the carotenoid
Wanqiang Sheng et al.
Cell research, 24(12), 1387-1402 (2014-11-22)
T helper (TH)-cell subsets, such as TH1 and TH17, mediate inflammation in both peripheral tissues and central nervous system. Here we show that STAT5 is required for T helper-cell pathogenicity in autoimmune neuroinflammation but not in experimental colitis. Although STAT5
Olivier Govaere et al.
Gut, 63(4), 674-685 (2013-08-21)
Keratin (K)19, a biliary/hepatic progenitor cell (HPC) marker, is expressed in a subset of hepatocellular carcinomas (HCC) with poor prognosis. The underlying mechanisms driving this phenotype of K19-positive HCC remain elusive. Clinicopathological value of K19 was compared with EpCAM, and
Oleg S Matusovsky et al.
The Journal of physiology, 592(14), 2999-3012 (2014-04-02)
Abundant data indicate that pathogenesis in allergic airways disease is orchestrated by an aberrant T-helper 2 (Th2) inflammatory response. CD4(+) T cells have been localized to airway smooth muscle (ASM) in both human asthmatics and in rodent models of allergic
Oleksiy Krupin et al.
Optics express, 21(1), 698-709 (2013-02-08)
Straight long-range surface plasmon waveguides are demonstrated as biosensors for the detection of cells, proteins and changes in the bulk refractive index of solutions. The sensors consist of 5 μm wide 22 nm thick Au stripes embedded in polymer (CYTOP™)

Fragen

1-2 von 2 Fragen  
  1. How is shipping temperature determined? And how is it related to the product storage temperature?

    1 Antwort
    1. Products may be shipped at a different temperature than the recommended long-term storage temperature. If the product quality is sensitive to short-term exposure to conditions other than the recommended long-term storage, it will be shipped on wet or dry-ice. If the product quality is NOT affected by short-term exposure to conditions other than the recommended long-term storage, it will be shipped at ambient temperature. As shipping routes are configured for minimum transit times, shipping at ambient temperature helps control shipping costs for our customers. For more information, please refer to the Storage and Transport Conditions document: https://www.sigmaaldrich.com/deepweb/assets/sigmaaldrich/marketing/global/documents/316/622/storage-transport-conditions-mk.pdf

      Hilfreich?

  2. How can I determine the shelf life / expiration / retest date of this product?

    1 Antwort
    1. If this product has an expiration or retest date, it will be shown on the Certificate of Analysis (COA, CofA). If there is no retest or expiration date listed on the product's COA, we do not have suitable stability data to determine a shelf life. For these products, the only date on the COA will be the release date; a retest, expiration, or use-by-date will not be displayed.
      For all products, we recommend handling per defined conditions as printed in our product literature and website product descriptions. We recommend that products should be routinely inspected by customers to ensure they perform as expected.
      For products without retest or expiration dates, our standard warranty of 1 year from the date of shipment is applicable.
      For more information, please refer to the Product Dating Information document: https://www.sigmaaldrich.com/deepweb/assets/sigmaaldrich/marketing/global/documents/449/386/product-dating-information-mk.pdf

      Hilfreich?

Bewertungen

Kein Beurteilungswert

Aktive Filter

Unser Team von Wissenschaftlern verfügt über Erfahrung in allen Forschungsbereichen einschließlich Life Science, Materialwissenschaften, chemischer Synthese, Chromatographie, Analytik und vielen mehr..