Direkt zum Inhalt
Merck

1.09533

Supelco

pH-Indikatorstäbchen pH 5,0 – 10,0

non-bleeding, colorimetric, pH range 5.0-10.0, graduations and accuracy accuracy: 0.5 pH unit, MQuant®

Synonym(e):

pH-Teststreifen, pH-Wert 5,0–10,0, pH-Teststäbchen, pH-Wert 5,0–10,0

Anmeldenzur Ansicht organisationsspezifischer und vertraglich vereinbarter Preise


About This Item

UNSPSC-Code:
41113034
NACRES:
NB.35
Preise und Verfügbarkeit sind derzeit nicht verfügbar.

Agentur

suitable for SM 5210

Qualitätsniveau

Produktlinie

MQuant®

Leistungsmerkmale

non-bleeding

graduations and accuracy measuring range

accuracy: 0.5 pH unit

pH-Bereich

5.0-10.0

Nachweisverfahren

colorimetric

Lagertemp.

2-30°C

Allgemeine Beschreibung

Die MQuant-pH-Tests sind für alle Medien in der Umweltanalyse und in industriellen In-Prozess-Kontrollen geeignet. Unser spezielles Herstellungsverfahren verleiht den pH-Indikatorstäbchen entscheidende Vorteile gegenüber Indikatorpapier: Da der Indikator nicht ausblutet, kann das Stäbchen im Messmedium verbleiben, ohne es zu kontaminieren. Die Verwendung des Teststäbchens ist relativ einfach: Der pH-Wert wird semiquantitativ gemessen, durch Sichtvergleich der drei Reaktionszonen des Teststäbchens mit den Feldern der Farbskala, die genau der Reaktionsfarbe entsprechen. Die praktischen Safetyedge-Behälter ermöglichen die sichere Aufbewahrung und das bequeme Herausnehmen der Teststäbchen. Bei Prüfungen anderer Parameter, für die ein bestimmter pH-Bereich der Probe erforderlich ist (z. B. Spectroquant, siehe Gebrauchsanleitung), empfehlen wir die Verwendung der MQuant-pH-Teststäbchen als Vortest.
nicht blutend pH 5,0 – 5,5 – 6,0 – 6,5 – 7,0 – 7,5 – 8,0 – 8,5 – 9,0 – 9,5 – 10 0 MQuant®

Verlinkung

Ersetzt: 9588-1; 9588-3; 9588

Hinweis zur Analyse

Anwendungstechnischer Test: entspricht

Rechtliche Hinweise

MQUANT is a registered trademark of Merck KGaA, Darmstadt, Germany

Lagerklassenschlüssel

11 - Combustible Solids

WGK

nwg


Analysenzertifikate (COA)

Suchen Sie nach Analysenzertifikate (COA), indem Sie die Lot-/Chargennummer des Produkts eingeben. Lot- und Chargennummern sind auf dem Produktetikett hinter den Wörtern ‘Lot’ oder ‘Batch’ (Lot oder Charge) zu finden.

Besitzen Sie dieses Produkt bereits?

In der Dokumentenbibliothek finden Sie die Dokumentation zu den Produkten, die Sie kürzlich erworben haben.

Die Dokumentenbibliothek aufrufen

Protokolle

Spektrophotometrische Bestimmung von Brom mit Dipropyl-p-phenylendiamin (DPD) in Trinkwasser, Schwimmbadwasser, Abwasser und Desinfektionslösungen in einem Bereich von 0,020 - 10,00 mg/l.

Spectrophotometric determination of bromine with dipropyl-p-phenylenediamine (DPD) in drinking water, swimming-pool water, wastewater, and disinfection solutions in a range of 0.020 – 10.00 mg/L.

Verwandter Inhalt

This page is intended to make it easier to find the consumables you need based on the analytical method you’re using. Methods included on this page come from the EPA, Standard Methods and ASTM.

Fragen

1-3 von 3 Fragen  
  1. How can I determine the shelf life / expiration / retest date of this product?

    1 Antwort
    1. If this product has an expiration or retest date, it will be shown on the Certificate of Analysis (COA, CofA). If there is no retest or expiration date listed on the product's COA, we do not have suitable stability data to determine a shelf life. For these products, the only date on the COA will be the release date; a retest, expiration, or use-by-date will not be displayed.
      For all products, we recommend handling per defined conditions as printed in our product literature and website product descriptions. We recommend that products should be routinely inspected by customers to ensure they perform as expected.
      For products without retest or expiration dates, our standard warranty of 1 year from the date of shipment is applicable.
      For more information, please refer to the Product Dating Information document: https://www.sigmaaldrich.com/deepweb/assets/sigmaaldrich/marketing/global/documents/449/386/product-dating-information-mk.pdf

      Hilfreich?

  2. How is shipping temperature determined? And how is it related to the product storage temperature?

    1 Antwort
    1. Products may be shipped at a different temperature than the recommended long-term storage temperature. If the product quality is sensitive to short-term exposure to conditions other than the recommended long-term storage, it will be shipped on wet or dry-ice. If the product quality is NOT affected by short-term exposure to conditions other than the recommended long-term storage, it will be shipped at ambient temperature. As shipping routes are configured for minimum transit times, shipping at ambient temperature helps control shipping costs for our customers. For more information, please refer to the Storage and Transport Conditions document: https://www.sigmaaldrich.com/deepweb/assets/sigmaaldrich/marketing/global/documents/316/622/storage-transport-conditions-mk.pdf

      Hilfreich?

  3. Do you have a Ph test strip for the 5.0 / 8.0 range that can discriminate by 0.5 Ph and works with the strip scan app?

    1 Antwort
    1. The only products that are compatible with the StripScan app read in pH increments of 1 rather than 0.5.

      Hilfreich?

Bewertungen

Kein Beurteilungswert

Aktive Filter

Unser Team von Wissenschaftlern verfügt über Erfahrung in allen Forschungsbereichen einschließlich Life Science, Materialwissenschaften, chemischer Synthese, Chromatographie, Analytik und vielen mehr..

Setzen Sie sich mit dem technischen Dienst in Verbindung.