Direkt zum Inhalt
Merck

790304C

Avanti

Coag Reagent I

Avanti Research - A Croda Brand 790304C

Synonym(e):

Coag Reagent, Coagulation Reagent I, contains DOPE:DOPS:DOPC (5:3:2 w/w)

Anmeldenzur Ansicht organisationsspezifischer und vertraglich vereinbarter Preise


About This Item

UNSPSC-Code:
12352211
NACRES:
NA.25

Form

liquid

Verpackung

pkg of 1 × 2.5 mL (790304C-25mg)
pkg of 2 × 4 mL (790304C-200mg)

Hersteller/Markenname

Avanti Research - A Croda Brand 790304C

Konzentration

10 mg/mL (790304C-25mg)
25 mg/mL (790304C-200mg)

Lipid-Typ

phospholipids

Versandbedingung

dry ice

Lagertemp.

−20°C

Suchen Sie nach ähnlichen Produkten? Aufrufen Leitfaden zum Produktvergleich

Anwendung

Coag. Reagent I has been used for the preparation of small unilamellar vesicles (SUVs).

Verpackung

5 mL Clear Glass Sealed Ampule (790304C-200mg)
5 mL Clear Glass Sealed Ampule (790304C-25mg)

Rechtliche Hinweise

Avanti Research is a trademark of Avanti Polar Lipids, LLC

Piktogramme

Skull and crossbonesHealth hazard

Signalwort

Danger

Gefahreneinstufungen

Acute Tox. 3 Inhalation - Acute Tox. 4 Oral - Aquatic Chronic 3 - Carc. 2 - Eye Irrit. 2 - Repr. 2 - Skin Irrit. 2 - STOT RE 1 - STOT SE 3

Zielorgane

Central nervous system, Liver,Kidney

Lagerklassenschlüssel

6.1C - Combustible acute toxic Cat.3 / toxic compounds or compounds which causing chronic effects

WGK

WGK 3

Flammpunkt (°F)

Not applicable

Flammpunkt (°C)

Not applicable


Analysenzertifikate (COA)

Suchen Sie nach Analysenzertifikate (COA), indem Sie die Lot-/Chargennummer des Produkts eingeben. Lot- und Chargennummern sind auf dem Produktetikett hinter den Wörtern ‘Lot’ oder ‘Batch’ (Lot oder Charge) zu finden.

Besitzen Sie dieses Produkt bereits?

In der Dokumentenbibliothek finden Sie die Dokumentation zu den Produkten, die Sie kürzlich erworben haben.

Die Dokumentenbibliothek aufrufen

A M van den Besselaar et al.
Blood coagulation & fibrinolysis : an international journal in haemostasis and thrombosis, 4(6), 895-903 (1993-12-01)
The activated partial thromboplastin time (aPTT) is the most popular test for monitoring of heparin therapy. The purpose of the present study was to show that an aPTT reagent with good response to heparin can be prepared from synthetic phosphoglycerides.
Nuclear magnetic resonance observation of ?-synuclein membrane interaction by monitoring the acetylation reactivity of its lysine side chains
Lee JH, et al.
Biochemistry, 55(35), 4949-4959 (2016)
A M van den Besselaar et al.
Clinical chemistry, 43(7), 1215-1222 (1997-07-01)
To contribute to the development of a reference reagent for monitoring heparin therapy, a lyophilized partial thromboplastin time (PTT) reagent was prepared from synthetic dioleoylphosphatidylcholine, dioleoylphosphatidylserine, and dioleoylphosphatidylethanolamine, with colloidal silica as activator. The reagent, coded 91/558, was contained in
Three-Dimensional Heterogeneous Structure Formation on a Supported Lipid Bilayer Disclosed by Single-Particle Tracking
Zhong Y & Wang G
Langmuir, 34(39), 11857-11865 (2018)
Yaning Zhong et al.
Langmuir : the ACS journal of surfaces and colloids, 34(39), 11857-11865 (2018-09-02)
Three-dimensional (3D) single-particle tracking was employed to study the lipid membrane morphology change at different pHs on glass supported lipid bilayers (SLBs) [1,2-dioleoyl- sn-glycero-3-phosphoethanolamine/1,2-dioleoyl- sn-glycero-3-phospho-l-serine (sodium salt)/1,2-dioleoyl- sn-glycero-3-phosphocholine = 5:3:2]. Fluorescently tagged, carboxylated polystyrene nanoparticles (of 100 nm) were used

Unser Team von Wissenschaftlern verfügt über Erfahrung in allen Forschungsbereichen einschließlich Life Science, Materialwissenschaften, chemischer Synthese, Chromatographie, Analytik und vielen mehr..

Setzen Sie sich mit dem technischen Dienst in Verbindung.